Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMI3-72-290 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI3-72-290 is a 290.0 W STC (261.0 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.92% efficiency, 44.46 V Voc at 25 C, and 49.74 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
261.0 W
Voc @ 25C
44.46 V
Efficiency
14.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI3-72-290 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for US Solar USS-QCMI3-72-290 (Multi-c-Si) residential solar systems.

US Solar USS-QCMI3-72-290 delivers 149.2 W/m2 (4.99 percentage points below 19.91% CEC median) and typical 90.0% PTC-to-STC thermal output (261.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (586 sq ft). At -4 F (-20 C), string voltage climbs to 51.24 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Centrosolar America DM72 290 (290.0 W).

Where Does US Solar USS-QCMI3-72-290 Fall Across Listed CEC Models?

Comparison of US Solar USS-QCMI3-72-290 (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI3-72-290 (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI3: 290.0 W

What Dataset Percentiles Define US Solar USS-QCMI3-72-290?

Relative ranking of US Solar USS-QCMI3-72-290 across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

US Solar USS-QCMI3-72-290 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI3-72-290 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.0%Module Efficiency14.92%

What Do the Dataset Ranks Show for US Solar USS-QCMI3-72-290?

Summary of US Solar USS-QCMI3-72-290 output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,877

14.92% Aperture Efficiency

Power density 149.2 W/m2 (4.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.74 V at -10 C (596.9 V string) and 51.24 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.4 m2 (586 sq ft) producing 7,308 W PTC; NEC 690.8 OCPD floor is 13.29 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.46 * (1 + (-0.339/100) * (-10 - 25)) = 49.74 V | OCPD = 1.56 * 8.52 = 13.29 A

Inputs from CEC Modules.csv for US Solar USS-QCMI3-72-290: Voc=44.46 V, beta_Voc=-0.339%/C, Isc=8.52 A, STC=290.0 W, Area=1.944 m2.

Result: 12 panels max on 600 V (596.9 V); 28 panels for 8 kW (586 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI3-72-290?

Complete CEC test sheet for US Solar USS-QCMI3-72-290 including Isc (8.52 A), Voc (44.46 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI3-72-290.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 261.0 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.46 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.16 V / 8.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.92% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI3-72-290 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using US Solar USS-QCMI3-72-290.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 586 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 732 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Related US Solar power steps and black/silver trims consolidated into this US Solar USS-QCMI3-72-290 series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the US Solar USS-QCMI3-72-290 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI3-72-280 280.0 W 251.8 W 44.15 V 35.78 V 14.4%
US Solar USS-QCMI3-72-285 285.0 W 256.4 W 44.32 V 36.02 V 14.66%
US Solar USS-QCMI3-72-290 290.0 W 261.0 W 44.46 V 36.16 V 14.92%
US Solar USS-QCMI3-72-295 295.0 W 265.7 W 44.68 V 36.38 V 15.17%

How Many US Solar USS-QCMI3-72-290 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for US Solar USS-QCMI3-72-290 (44.46 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.46V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.24 V 11 panels 563.6 V 19 panels
-10 C (14 F) 49.74 V 12 panels 596.9 V 20 panels
0 C (32 F) 48.23 V 12 panels 578.8 V 20 panels
25 C (77 F STC) 44.46 V 13 panels 578.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-72-290?

Four comparable CEC modules such as Centrosolar America DM72 290 (290.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-72-290?

Evaluate US Solar USS-QCMI3-72-290 (290.0 W STC, 44.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-72-290 reaches 51.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (586 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-72-290 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI3-72-290 8 kW Residential Fit

Needs 28 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI3-72-290 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many US Solar USS-QCMI3-72-290 panels fit on a 600 V winter solar string?

At -10 C (14 F), US Solar USS-QCMI3-72-290 cold Voc rises from 44.46 V to 49.74 V (beta_Voc -0.339%/C), capping a 600 V string at 12 panels (596.9 V).

How much roof area does an 8 kW array of US Solar USS-QCMI3-72-290 need?

An 8 kW DC system uses 28 US Solar USS-QCMI3-72-290 modules (8,120 W STC / 7,308 W PTC), covering roughly 586 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does US Solar USS-QCMI3-72-290 compare against Centrosolar America DM72 290?

US Solar USS-QCMI3-72-290 outputs 290.0 W STC (44.46 V Voc, rank #17,253 of 21,677), while Centrosolar America DM72 290 delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.