Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-290M/156-72S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-290M/156-72S is a 290.0 W STC (262.6 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 44.98 V Voc at 25 C, and 50.58 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
262.6 W
Voc @ 25C
44.98 V
Efficiency
14.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-290M/156-72S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-290M/156-72S (Mono-c-Si) residential solar systems.

AXITEC AC-290M/156-72S delivers 149.5 W/m2 (4.96 percentage points below 19.91% CEC median) and typical 90.6% PTC-to-STC thermal output (262.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft). At -4 F (-20 C), string voltage climbs to 52.19 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Gintung Energy GTEC-290G6S (290.0 W).

Where Does AXITEC AC-290M/156-72S Fall Across Listed CEC Models?

Comparison of AXITEC AC-290M/156-72S (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-290M/156-72S (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-290M/156: 290.0 W

What Dataset Percentiles Define AXITEC AC-290M/156-72S?

Relative ranking of AXITEC AC-290M/156-72S across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AXITEC AC-290M/156-72S Engineering BenchmarksPercentile comparison of AXITEC AC-290M/156-72S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.6%Module Efficiency14.95%

What Do the Dataset Ranks Show for AXITEC AC-290M/156-72S?

Summary of AXITEC AC-290M/156-72S output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,805

14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.58 V at -10 C (556.4 V string) and 52.19 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,353 W PTC; NEC 690.8 OCPD floor is 13.34 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.98 * (1 + (-0.356/100) * (-10 - 25)) = 50.58 V | OCPD = 1.56 * 8.55 = 13.34 A

Inputs from CEC Modules.csv for AXITEC AC-290M/156-72S: Voc=44.98 V, beta_Voc=-0.356%/C, Isc=8.55 A, STC=290.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (556.4 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for AXITEC AC-290M/156-72S?

Complete CEC test sheet for AXITEC AC-290M/156-72S including Isc (8.55 A), Voc (44.98 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-290M/156-72S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 262.6 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.4 V / 7.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.356 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.95% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-290M/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-290M/156-72S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 585 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 731 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-290M/156-72S series guide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the AXITEC AC-290M/156-72S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-285M/156-72S 285.0 W 258.0 W 44.78 V 36.03 V 14.69%
AXITEC AC-290M/156-72S 290.0 W 262.6 W 44.98 V 36.4 V 14.95%
AXITEC AC-295M/156-72S 295.0 W 265.8 W 45.01 V 36.48 V 15.23%

How Many AXITEC AC-290M/156-72S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-290M/156-72S (44.98 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.98V and beta_Voc=-0.356%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.19 V 11 panels 574.1 V 19 panels
-10 C (14 F) 50.58 V 11 panels 556.4 V 19 panels
0 C (32 F) 48.98 V 12 panels 587.8 V 20 panels
25 C (77 F STC) 44.98 V 13 panels 584.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-290M/156-72S?

Four comparable CEC modules such as Gintung Energy GTEC-290G6S (290.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W +5.0 W 44.9 V 15.21% 91.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-290M/156-72S?

Evaluate AXITEC AC-290M/156-72S (290.0 W STC, 44.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-290M/156-72S reaches 52.19 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-290M/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-290M/156-72S 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy GTEC-290G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-290M/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-290M/156-72S panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-290M/156-72S cold Voc rises from 44.98 V to 50.58 V (beta_Voc -0.356%/C), capping a 600 V string at 11 panels (556.4 V).

How much roof area does an 8 kW array of AXITEC AC-290M/156-72S need?

An 8 kW DC system uses 28 AXITEC AC-290M/156-72S modules (8,120 W STC / 7,353 W PTC), covering roughly 585 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does AXITEC AC-290M/156-72S compare against Gintung Energy GTEC-290G6S?

AXITEC AC-290M/156-72S outputs 290.0 W STC (44.98 V Voc, rank #17,253 of 21,677), while Gintung Energy GTEC-290G6S delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.