Centrosolar America DM72 290 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DM72 290 is a 290.0 W STC (262.8 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.92% efficiency, 44.4 V Voc at 25 C, and 49.43 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
262.8 W
Voc @ 25C
44.4 V
Efficiency
14.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DM72 290 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America DM72 290 (Mono-c-Si) residential solar systems.

Homeowners evaluating Centrosolar America DM72 290 need 21 panels for 6 kW or 28 panels (586 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (586 sq ft). Under NEC 690.7(A), beta_Voc (-0.324%/C) pushes open-circuit voltage to 49.43 V at 14 F and 50.87 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America DM72 290 Fall Across Listed CEC Models?

Comparison of Centrosolar America DM72 290 (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DM72 290 (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 290.0 W

What Dataset Percentiles Define Centrosolar America DM72 290?

Relative ranking of Centrosolar America DM72 290 across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency.

Centrosolar America DM72 290 Engineering BenchmarksPercentile comparison of Centrosolar America DM72 290 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.6%Module Efficiency14.92%

What Do the Dataset Ranks Show for Centrosolar America DM72 290?

Summary of Centrosolar America DM72 290 output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,877

14.92% Aperture Efficiency

Power density 149.2 W/m2 (4.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.43 V at -10 C (593.2 V string) and 50.87 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.4 m2 (586 sq ft) producing 7,358 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.4 * (1 + (-0.324/100) * (-10 - 25)) = 49.43 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for Centrosolar America DM72 290: Voc=44.4 V, beta_Voc=-0.324%/C, Isc=8.6 A, STC=290.0 W, Area=1.944 m2.

Result: 12 panels max on 600 V (593.2 V); 28 panels for 8 kW (586 sq ft).

What Are the Published CEC Specifications for Centrosolar America DM72 290?

Complete CEC test sheet for Centrosolar America DM72 290 including Isc (8.6 A), Voc (44.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DM72 290.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 262.8 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.3 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.92% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America DM72 290 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America DM72 290.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 586 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 732 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Related Centrosolar America power steps and black/silver trims consolidated into this Centrosolar America DM72 290 series guide.

Sibling CEC listings grouped into the Centrosolar America DM72 290 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DM72 285 285.0 W 258.2 W 44.1 V 35.7 V 14.66%
Centrosolar America DM72 290 290.0 W 262.8 W 44.4 V 36.3 V 14.92%
Centrosolar America DM72 295 295.0 W 267.5 W 44.7 V 36.5 V 15.17%

How Many Centrosolar America DM72 290 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America DM72 290 (44.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.4V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.87 V 11 panels 559.6 V 19 panels
-10 C (14 F) 49.43 V 12 panels 593.2 V 20 panels
0 C (32 F) 48.0 V 12 panels 576.0 V 20 panels
25 C (77 F STC) 44.4 V 13 panels 577.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DM72 290?

Four comparable CEC modules such as Gintung Energy GTEC-290G6M (290.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W +5.0 W 44.4 V 15.28% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DM72 290?

Evaluate Centrosolar America DM72 290 (290.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DM72 290 reaches 50.87 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (586 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DM72 290 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DM72 290 8 kW Residential Fit

Needs 28 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy GTEC-290G6M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DM72 290 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America DM72 290 PTC wattage (262.8 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 262.8 W PTC (90.6% retention) across Centrosolar America DM72 290's 1.944 m2 aperture.

Who should skip Centrosolar America DM72 290 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Centrosolar America DM72 290 panels (586 sq ft) leave unusable roof gaps vs. Gintung Energy GTEC-290G6M.

What is the 1,000 V commercial string limit for Centrosolar America DM72 290?

On 1,000 V commercial inverters at -10 C (49.43 V cold Voc), Centrosolar America DM72 290 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America DM72 290.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.