Gintung Energy GTEC-290G6S is a 290.0 W STC (260.2 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.83% efficiency, 44.84 V Voc at 25 C, and 50.18 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 260.2 W
- Voc @ 25C
- 44.84 V
- Efficiency
- 14.83%
How Does Gintung Energy GTEC-290G6S Compare Against Peer CEC Listings?
Solar engineering breakdown for Gintung Energy GTEC-290G6S: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Measured at 290.0 W STC and 260.2 W PTC, Gintung Energy GTEC-290G6S sits -95.0 W vs all-CEC median (below all-CEC median; higher than 18.8% of peers) among 21,677 listed modules. Power density reaches 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). Mid-range 44.84 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer AXITEC AC-290M/156-72S rates 290.0 W.
Where Does Gintung Energy GTEC-290G6S Fall Across Listed CEC Models?
Distribution marker showing Gintung Energy GTEC-290G6S (290.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Gintung Energy GTEC-290G6S?
Dataset percentiles tracking Gintung Energy GTEC-290G6S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for Gintung Energy GTEC-290G6S?
Benchmark highlights for Gintung Energy GTEC-290G6S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.83% Aperture Efficiency
Power density 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.18 V at -10 C (552.0 V string) and 51.7 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.8 m2 (590 sq ft) producing 7,286 W PTC; NEC 690.8 OCPD floor is 13.65 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.84 * (1 + (-0.34/100) * (-10 - 25)) = 50.18 V | OCPD = 1.56 * 8.75 = 13.65 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-290G6S: Voc=44.84 V, beta_Voc=-0.34%/C, Isc=8.75 A, STC=290.0 W, Area=1.956 m2.
Result: 11 panels max on 600 V (552.0 V); 28 panels for 8 kW (590 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-290G6S?
Official CEC datasheet figures for Gintung Energy GTEC-290G6S (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 260.2 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.16 V / 8.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.83% (1.956 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-290G6S Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gintung Energy GTEC-290G6S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 442 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 590 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 737 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-290G6S mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-280G6S | 280.0 W | 251.0 W | 44.55 V | 34.96 V | 14.31% |
| Gintung Energy GTEC-285G6S | 285.0 W | 255.6 W | 44.69 V | 35.06 V | 14.57% |
| Gintung Energy GTEC-290G6S | 290.0 W | 260.2 W | 44.84 V | 35.16 V | 14.83% |
| Gintung Energy GTEC-295G6S | 295.0 W | 258.2 W | 44.96 V | 35.33 V | 15.08% |
How Many Gintung Energy GTEC-290G6S Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-290G6S (50.18 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.7 V | 11 panels | 568.7 V | 19 panels |
| -10 C (14 F) | 50.18 V | 11 panels | 552.0 V | 19 panels |
| 0 C (32 F) | 48.65 V | 12 panels | 583.8 V | 20 panels |
| 25 C (77 F STC) | 44.84 V | 13 panels | 582.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-290G6S?
Competing CEC solar panels closest to Gintung Energy GTEC-290G6S in nameplate wattage and Voc, starting with AXITEC AC-290M/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | +5.0 W | 44.9 V | 15.21% | 91.5% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | +5.0 W | 45.1 V | 15.13% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-290G6S?
Evaluate Gintung Energy GTEC-290G6S (290.0 W STC, 44.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-290G6S reaches 51.7 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (590 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-290G6S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-290G6S 8 kW Residential Fit
Needs 28 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 260.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-290G6S by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy GTEC-290G6S panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy GTEC-290G6S cold Voc rises from 44.84 V to 50.18 V (beta_Voc -0.34%/C), capping a 600 V string at 11 panels (552.0 V).
How much roof area does an 8 kW array of Gintung Energy GTEC-290G6S need?
An 8 kW DC system uses 28 Gintung Energy GTEC-290G6S modules (8,120 W STC / 7,286 W PTC), covering roughly 590 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Gintung Energy GTEC-290G6S compare against AXITEC AC-290M/156-72S?
Gintung Energy GTEC-290G6S outputs 290.0 W STC (44.84 V Voc, rank #17,253 of 21,677), while AXITEC AC-290M/156-72S delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)