Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America TP7 295xx — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America TP7 295xx is a 295.0 W STC (266.6 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.13% efficiency, 45.1 V Voc at 25 C, and 49.99 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
266.6 W
Voc @ 25C
45.1 V
Efficiency
15.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America TP7 295xx Compare Against Peer CEC Listings?

Engineering position of Centrosolar America TP7 295xx (295.0 W STC) vs. BYD Company Limited BYD295P6K-36 across 1,407 CEC Multi-c-Si solar modules.

Ranking #16,890 across 21,677 CEC solar panels (below all-CEC median; higher than 20.4% of peers), Centrosolar America TP7 295xx operates as a compact residential or specialty off-grid module sitting 16.2 W above the 278.8 W Multi-c-Si median. Mid-range 45.1 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 90.4% PTC-to-STC thermal output (266.6 W real-world rating), 28 panels occupy 588 sq ft and offset roughly $2,067/yr at average US rates (or $3,496/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America TP7 295xx Fall Across Listed CEC Models?

Plots Centrosolar America TP7 295xx at 295.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America TP7 295xx (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 295.0 W

What Dataset Percentiles Define Centrosolar America TP7 295xx?

Benchmarks Centrosolar America TP7 295xx on STC wattage, thermal PTC/STC retention, and 15.13 aperture conversion efficiency against CEC peers.

Centrosolar America TP7 295xx Engineering BenchmarksPercentile comparison of Centrosolar America TP7 295xx wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention90.4%Module Efficiency15.13%

What Do the Dataset Ranks Show for Centrosolar America TP7 295xx?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America TP7 295xx by Centrosolar America.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,550

15.13% Aperture Efficiency

Power density 151.3 W/m2 (4.78 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.99 V at -10 C (599.9 V string) and 51.39 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 54.6 m2 (588 sq ft) producing 7,465 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.1 * (1 + (-0.31/100) * (-10 - 25)) = 49.99 V | OCPD = 1.56 * 8.62 = 13.45 A

Inputs from CEC Modules.csv for Centrosolar America TP7 295xx: Voc=45.1 V, beta_Voc=-0.31%/C, Isc=8.62 A, STC=295.0 W, Area=1.95 m2.

Result: 12 panels max on 600 V (599.9 V); 28 panels for 8 kW (588 sq ft).

What Are the Published CEC Specifications for Centrosolar America TP7 295xx?

Laboratory test ratings recorded for Centrosolar America TP7 295xx (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America TP7 295xx.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 266.6 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.5 V / 8.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.13% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America TP7 295xx Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (588 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America TP7 295xx.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 441 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 588 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 714 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Sibling wattage bins and frame colors grouped with Centrosolar America TP7 295xx under Centrosolar America to prevent duplicate spec pages.

Sibling CEC listings grouped into the Centrosolar America TP7 295xx wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America TP7 290xx 290.0 W 262.0 W 44.9 V 36.3 V 14.87%
Centrosolar America TP7 295xx 295.0 W 266.6 W 45.1 V 36.5 V 15.13%

How Many Centrosolar America TP7 295xx Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Centrosolar America TP7 295xx (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.1V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.39 V 11 panels 565.3 V 19 panels
-10 C (14 F) 49.99 V 12 panels 599.9 V 20 panels
0 C (32 F) 48.6 V 12 panels 583.2 V 20 panels
25 C (77 F STC) 45.1 V 13 panels 586.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America TP7 295xx?

Closest cross-brand CEC competitors to Centrosolar America TP7 295xx matched near 295.0 W STC and 45.1 V Voc, led by BYD Company Limited BYD295P6K-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W Tie (0 W) 44.9 V 15.21% 91.5%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W Tie (0 W) 44.4 V 15.28% 90.2%
AXITEC AC-290M/156-72S
AXITEC
290.0 W -5.0 W 44.98 V 14.95% 90.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W -5.0 W 44.84 V 14.83% 89.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America TP7 295xx?

Evaluate Centrosolar America TP7 295xx (295.0 W STC, 45.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America TP7 295xx reaches 51.39 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America TP7 295xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America TP7 295xx 8 kW Residential Fit

Needs 28 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 266.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America TP7 295xx by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Centrosolar America TP7 295xx panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America TP7 295xx cold Voc rises from 45.1 V to 49.99 V (beta_Voc -0.31%/C), capping a 600 V string at 12 panels (599.9 V).

How much roof area does an 8 kW array of Centrosolar America TP7 295xx need?

An 8 kW DC system uses 28 Centrosolar America TP7 295xx modules (8,260 W STC / 7,465 W PTC), covering roughly 588 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does Centrosolar America TP7 295xx compare against BYD Company Limited BYD295P6K-36?

Centrosolar America TP7 295xx outputs 295.0 W STC (45.1 V Voc, rank #16,890 of 21,677), while BYD Company Limited BYD295P6K-36 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.