US Solar USS-QCMI3-72-330 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI3-72-330 is a 330.0 W STC (298.2 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 16.97% efficiency, 45.8 V Voc at 25 C, and 51.23 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
298.2 W
Voc @ 25C
45.8 V
Efficiency
16.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI3-72-330 Compare Against Peer CEC Listings?

How US Solar US Solar USS-QCMI3-72-330 handles rooftop heat (298.2 W PTC), 8 kW sizing, and cold winter string voltage.

US Solar builds the US Solar USS-QCMI3-72-330 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 169.8 W/m2 (2.94 percentage points below 19.91% CEC median). Compared against Centrosolar America DP72 330 (330.0 W), this model holds typical 90.4% PTC-to-STC thermal output (298.2 W real-world rating). Mid-range 45.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.76 A overcurrent floor served by a 15 A breaker.

Where Does US Solar USS-QCMI3-72-330 Fall Across Listed CEC Models?

Where US Solar USS-QCMI3-72-330 (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI3-72-330 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI3: 330.0 W

What Dataset Percentiles Define US Solar USS-QCMI3-72-330?

Percentile placement of US Solar USS-QCMI3-72-330 across power density (169.8 W/m2), thermal retention, and nameplate STC wattage.

US Solar USS-QCMI3-72-330 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI3-72-330 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.4%Module Efficiency16.97%

What Do the Dataset Ranks Show for US Solar USS-QCMI3-72-330?

Four critical engineering numbers homeowners and solar installers check first when reviewing US Solar USS-QCMI3-72-330 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,576

16.97% Aperture Efficiency

Power density 169.8 W/m2 (2.94 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.23 V at -10 C (563.5 V string) and 52.79 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,455 W PTC; NEC 690.8 OCPD floor is 13.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.8 * (1 + (-0.339/100) * (-10 - 25)) = 51.23 V | OCPD = 1.56 * 8.82 = 13.76 A

Inputs from CEC Modules.csv for US Solar USS-QCMI3-72-330: Voc=45.8 V, beta_Voc=-0.339%/C, Isc=8.82 A, STC=330.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (563.5 V); 25 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI3-72-330?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for US Solar USS-QCMI3-72-330.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI3-72-330.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 298.2 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.62 V / 8.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.97% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI3-72-330 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using US Solar USS-QCMI3-72-330 (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 398 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 523 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 649 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

All closely matched US Solar wattages and cosmetic trims sharing the US Solar USS-QCMI3-72-330 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the US Solar USS-QCMI3-72-330 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI3-72-325 325.0 W 293.5 W 45.65 V 38.32 V 16.72%
US Solar USS-QCMI3-72-330 330.0 W 298.2 W 45.8 V 38.62 V 16.97%

How Many US Solar USS-QCMI3-72-330 Modules Fit in a Cold-Weather String?

Maximum series module counts for US Solar USS-QCMI3-72-330 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.8V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.79 V 11 panels 580.7 V 18 panels
-10 C (14 F) 51.23 V 11 panels 563.5 V 19 panels
0 C (32 F) 49.68 V 12 panels 596.2 V 20 panels
25 C (77 F STC) 45.8 V 13 panels 595.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-72-330?

Alternative CEC solar modules from competing brands near US Solar USS-QCMI3-72-330 (330.0 W), including Centrosolar America DP72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP72 330
Centrosolar America
330.0 W Tie (0 W) 45.8 V 16.97% 90.4%
AXITEC AC-330P/72S
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
AXITEC AC-330P/72V
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
CSI Solar Co Ltd CS6X-330P
CSI Solar Co Ltd
330.0 W Tie (0 W) 45.6 V 17.36% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-72-330?

Evaluate US Solar USS-QCMI3-72-330 (330.0 W STC, 45.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-72-330 reaches 52.79 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-72-330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI3-72-330 8 kW Residential Fit

Needs 25 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI3-72-330 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMI3-72-330?

Multiplying US Solar USS-QCMI3-72-330's 8.82 A short-circuit current by 1.56 equals 13.76 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can US Solar USS-QCMI3-72-330 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.23 V cold Voc at 14 F and handles 8.82 A Isc; string inverters cap US Solar USS-QCMI3-72-330 at 11 panels on 600 V.

Is US Solar USS-QCMI3-72-330 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMI3-72-330 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.