AXITEC AC-330P/72S is a 330.0 W STC (304.5 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.1% efficiency, 45.97 V Voc at 25 C, and 50.78 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 304.5 W
- Voc @ 25C
- 45.97 V
- Efficiency
- 17.1%
How Does AXITEC AC-330P/72S Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-330P/72S: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Measured at 330.0 W STC and 304.5 W PTC, AXITEC AC-330P/72S sits -55.0 W vs all-CEC median (below all-CEC median; higher than 32.9% of peers) among 21,677 listed modules. Power density reaches 171.0 W/m2 (2.81 percentage points below 19.91% CEC median). Mid-range 45.97 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Advance Power API-P330 rates 330.0 W.
Where Does AXITEC AC-330P/72S Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-330P/72S (330.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define AXITEC AC-330P/72S?
Dataset percentiles tracking AXITEC AC-330P/72S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for AXITEC AC-330P/72S?
Benchmark highlights for AXITEC AC-330P/72S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.1% Aperture Efficiency
Power density 171.0 W/m2 (2.81 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.78 V at -10 C (558.6 V string) and 52.16 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.2 m2 (519 sq ft) producing 7,612 W PTC; NEC 690.8 OCPD floor is 14.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.97 * (1 + (-0.299/100) * (-10 - 25)) = 50.78 V | OCPD = 1.56 * 9.28 = 14.48 A
Inputs from CEC Modules.csv for AXITEC AC-330P/72S: Voc=45.97 V, beta_Voc=-0.299%/C, Isc=9.28 A, STC=330.0 W, Area=1.93 m2.
Result: 11 panels max on 600 V (558.6 V); 25 panels for 8 kW (519 sq ft).
What Are the Published CEC Specifications for AXITEC AC-330P/72S?
Official CEC datasheet figures for AXITEC AC-330P/72S (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 304.5 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.97 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.8 V / 8.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.299 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.1% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many AXITEC AC-330P/72S Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-330P/72S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 395 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 519 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 644 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Consolidated AXITEC wattage variants sharing the AXITEC AC-330P/72S mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-325P/72S | 325.0 W | 299.8 W | 45.92 V | 37.66 V | 16.84% |
| AXITEC AC-330P/72S | 330.0 W | 304.5 W | 45.97 V | 37.8 V | 17.1% |
| AXITEC AC-335P/72S | 335.0 W | 309.2 W | 46.45 V | 37.98 V | 17.36% |
How Many AXITEC AC-330P/72S Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-330P/72S (50.78 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.16 V | 11 panels | 573.8 V | 19 panels |
| -10 C (14 F) | 50.78 V | 11 panels | 558.6 V | 19 panels |
| 0 C (32 F) | 49.41 V | 12 panels | 592.9 V | 20 panels |
| 25 C (77 F STC) | 45.97 V | 13 panels | 597.6 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-330P/72S?
Competing CEC solar panels closest to AXITEC AC-330P/72S in nameplate wattage and Voc, starting with Advance Power API-P330.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P330 Advance Power |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Auxin Solar AXN6P612T330 Auxin Solar |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Centrosolar America TM7 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Centrosolar America TM7S 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-330P/72S?
Evaluate AXITEC AC-330P/72S (330.0 W STC, 45.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-330P/72S reaches 52.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 519 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (519 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-330P/72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-330P/72S 8 kW Residential Fit
Needs 25 modules (519 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P330.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-330P/72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-330P/72S panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-330P/72S cold Voc rises from 45.97 V to 50.78 V (beta_Voc -0.299%/C), capping a 600 V string at 11 panels (558.6 V).
How much roof area does an 8 kW array of AXITEC AC-330P/72S need?
An 8 kW DC system uses 25 AXITEC AC-330P/72S modules (8,250 W STC / 7,612 W PTC), covering roughly 519 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does AXITEC AC-330P/72S compare against Advance Power API-P330?
AXITEC AC-330P/72S outputs 330.0 W STC (45.97 V Voc, rank #14,165 of 21,677), while Advance Power API-P330 delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)