Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-330P/72V — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-330P/72V is a 330.0 W STC (304.5 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.1% efficiency, 45.97 V Voc at 25 C, and 50.78 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
304.5 W
Voc @ 25C
45.97 V
Efficiency
17.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-330P/72V Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-330P/72V (Multi-c-Si) residential solar systems.

AXITEC AC-330P/72V delivers 171.0 W/m2 (2.81 percentage points below 19.91% CEC median) and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (519 sq ft). At -4 F (-20 C), string voltage climbs to 52.16 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Advance Power API-P330 (330.0 W).

Where Does AXITEC AC-330P/72V Fall Across Listed CEC Models?

Comparison of AXITEC AC-330P/72V (330.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-330P/72V (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-330P/72V: 330.0 W

What Dataset Percentiles Define AXITEC AC-330P/72V?

Relative ranking of AXITEC AC-330P/72V across nameplate watts, 92.3% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AXITEC AC-330P/72V Engineering BenchmarksPercentile comparison of AXITEC AC-330P/72V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention92.3%Module Efficiency17.1%

What Do the Dataset Ranks Show for AXITEC AC-330P/72V?

Summary of AXITEC AC-330P/72V output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,338

17.1% Aperture Efficiency

Power density 171.0 W/m2 (2.81 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.78 V at -10 C (558.6 V string) and 52.16 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.2 m2 (519 sq ft) producing 7,612 W PTC; NEC 690.8 OCPD floor is 14.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.97 * (1 + (-0.299/100) * (-10 - 25)) = 50.78 V | OCPD = 1.56 * 9.28 = 14.48 A

Inputs from CEC Modules.csv for AXITEC AC-330P/72V: Voc=45.97 V, beta_Voc=-0.299%/C, Isc=9.28 A, STC=330.0 W, Area=1.93 m2.

Result: 11 panels max on 600 V (558.6 V); 25 panels for 8 kW (519 sq ft).

What Are the Published CEC Specifications for AXITEC AC-330P/72V?

Complete CEC test sheet for AXITEC AC-330P/72V including Isc (9.28 A), Voc (45.97 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-330P/72V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 304.5 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.97 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.299 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.1% (1.93 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-330P/72V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-330P/72V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 395 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 519 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 644 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-330P/72V series guide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the AXITEC AC-330P/72V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-325P/72V 325.0 W 299.8 W 45.92 V 37.66 V 16.84%
AXITEC AC-330P/72V 330.0 W 304.5 W 45.97 V 37.8 V 17.1%
AXITEC AC-335P/72V 335.0 W 309.2 W 46.45 V 37.98 V 17.36%

How Many AXITEC AC-330P/72V Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-330P/72V (45.97 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.97V and beta_Voc=-0.299%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.16 V 11 panels 573.8 V 19 panels
-10 C (14 F) 50.78 V 11 panels 558.6 V 19 panels
0 C (32 F) 49.41 V 12 panels 592.9 V 20 panels
25 C (77 F STC) 45.97 V 13 panels 597.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-330P/72V?

Four comparable CEC modules such as Advance Power API-P330 (330.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P330
Advance Power
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
Auxin Solar AXN6P612T330
Auxin Solar
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
Centrosolar America TM7 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
Centrosolar America TM7S 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-330P/72V?

Evaluate AXITEC AC-330P/72V (330.0 W STC, 45.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-330P/72V reaches 52.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 519 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (519 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-330P/72V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-330P/72V 8 kW Residential Fit

Needs 25 modules (519 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-330P/72V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-330P/72V panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-330P/72V cold Voc rises from 45.97 V to 50.78 V (beta_Voc -0.299%/C), capping a 600 V string at 11 panels (558.6 V).

How much roof area does an 8 kW array of AXITEC AC-330P/72V need?

An 8 kW DC system uses 25 AXITEC AC-330P/72V modules (8,250 W STC / 7,612 W PTC), covering roughly 519 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does AXITEC AC-330P/72V compare against Advance Power API-P330?

AXITEC AC-330P/72V outputs 330.0 W STC (45.97 V Voc, rank #14,165 of 21,677), while Advance Power API-P330 delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls