Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMO3-72-330 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMO3-72-330 is a 330.0 W STC (300.1 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 16.97% efficiency, 46.9 V Voc at 25 C, and 52.22 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
300.1 W
Voc @ 25C
46.9 V
Efficiency
16.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMO3-72-330 Compare Against Peer CEC Listings?

Solar engineering breakdown for US Solar USS-QCMO3-72-330: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 5,889 Mono-c-Si listings from US Solar and peers, US Solar USS-QCMO3-72-330 stands 80.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (300.1 W real-world rating). Sizing 6 kW (19 panels) to 10 kW (31 panels) yields $1,569-$2,560/yr in baseline US bill offset. Mid-range 46.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does US Solar USS-QCMO3-72-330 Fall Across Listed CEC Models?

Distribution marker showing US Solar USS-QCMO3-72-330 (330.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMO3-72-330 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMO3: 330.0 W

What Dataset Percentiles Define US Solar USS-QCMO3-72-330?

Dataset percentiles tracking US Solar USS-QCMO3-72-330 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

US Solar USS-QCMO3-72-330 Engineering BenchmarksPercentile comparison of US Solar USS-QCMO3-72-330 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.9%Module Efficiency16.97%

What Do the Dataset Ranks Show for US Solar USS-QCMO3-72-330?

Benchmark highlights for US Solar USS-QCMO3-72-330 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,576

16.97% Aperture Efficiency

Power density 169.8 W/m2 (2.94 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.22 V at -10 C (574.4 V string) and 53.74 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,502 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.9 * (1 + (-0.324/100) * (-10 - 25)) = 52.22 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-72-330: Voc=46.9 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=330.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (574.4 V); 25 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMO3-72-330?

Official CEC datasheet figures for US Solar USS-QCMO3-72-330 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-72-330.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 300.1 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.3 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.97% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many US Solar USS-QCMO3-72-330 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many US Solar USS-QCMO3-72-330 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 398 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 523 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 649 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Consolidated US Solar wattage variants sharing the US Solar USS-QCMO3-72-330 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the US Solar USS-QCMO3-72-330 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMO3-72-325 325.0 W 295.4 W 46.6 V 38.7 V 16.72%
US Solar USS-QCMO3-72-330 330.0 W 300.1 W 46.9 V 39.3 V 16.97%
US Solar USS-QCMO3-72-335 335.0 W 304.8 W 47.2 V 39.5 V 17.23%

How Many US Solar USS-QCMO3-72-330 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMO3-72-330 (52.22 V at 14 F).

Computed from Voc=46.9V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.74 V 11 panels 591.1 V 18 panels
-10 C (14 F) 52.22 V 11 panels 574.4 V 19 panels
0 C (32 F) 50.7 V 11 panels 557.7 V 19 panels
25 C (77 F STC) 46.9 V 12 panels 562.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-72-330?

Competing CEC solar panels closest to US Solar USS-QCMO3-72-330 in nameplate wattage and Voc, starting with Centrosolar America DM72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 330
Centrosolar America
330.0 W Tie (0 W) 46.9 V 16.97% 90.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330BW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330SW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-72-330?

Evaluate US Solar USS-QCMO3-72-330 (330.0 W STC, 46.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-72-330 reaches 53.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-72-330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMO3-72-330 8 kW Residential Fit

Needs 25 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 300.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-72-330 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-72-330?

Multiplying US Solar USS-QCMO3-72-330's 9.0 A short-circuit current by 1.56 equals 14.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can US Solar USS-QCMO3-72-330 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.22 V cold Voc at 14 F and handles 9.0 A Isc; string inverters cap US Solar USS-QCMO3-72-330 at 11 panels on 600 V.

Is US Solar USS-QCMO3-72-330 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-72-330 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.