Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America EP72 330BW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EP72 330BW is a 330.0 W STC (301.3 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.16% efficiency, 46.65 V Voc at 25 C, and 51.76 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
301.3 W
Voc @ 25C
46.65 V
Efficiency
17.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EP72 330BW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America EP72 330BW (Multi-c-Si) residential solar systems.

Homeowners evaluating Centrosolar America EP72 330BW need 19 panels for 6 kW or 25 panels (517 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (517 sq ft). Under NEC 690.7(A), beta_Voc (-0.313%/C) pushes open-circuit voltage to 51.76 V at 14 F and 53.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America EP72 330BW Fall Across Listed CEC Models?

Comparison of Centrosolar America EP72 330BW (330.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EP72 330BW (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 330.0 W

What Dataset Percentiles Define Centrosolar America EP72 330BW?

Relative ranking of Centrosolar America EP72 330BW across nameplate watts, 91.3% PTC thermal ratio, and module aperture efficiency.

Centrosolar America EP72 330BW Engineering BenchmarksPercentile comparison of Centrosolar America EP72 330BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention91.3%Module Efficiency17.16%

What Do the Dataset Ranks Show for Centrosolar America EP72 330BW?

Summary of Centrosolar America EP72 330BW output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,261

17.16% Aperture Efficiency

Power density 171.6 W/m2 (2.75 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.76 V at -10 C (569.4 V string) and 53.22 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.1 m2 (517 sq ft) producing 7,532 W PTC; NEC 690.8 OCPD floor is 14.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.65 * (1 + (-0.313/100) * (-10 - 25)) = 51.76 V | OCPD = 1.56 * 9.35 = 14.59 A

Inputs from CEC Modules.csv for Centrosolar America EP72 330BW: Voc=46.65 V, beta_Voc=-0.313%/C, Isc=9.35 A, STC=330.0 W, Area=1.923 m2.

Result: 11 panels max on 600 V (569.4 V); 25 panels for 8 kW (517 sq ft).

What Are the Published CEC Specifications for Centrosolar America EP72 330BW?

Complete CEC test sheet for Centrosolar America EP72 330BW including Isc (9.35 A), Voc (46.65 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EP72 330BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 301.3 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.58 V / 8.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.16% (1.923 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America EP72 330BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America EP72 330BW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 393 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 517 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 642 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Related Centrosolar America power steps and black/silver trims consolidated into this Centrosolar America EP72 330BW series guide.

Sibling CEC listings grouped into the Centrosolar America EP72 330BW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America EP72 325BW 325.0 W 296.6 W 46.31 V 37.28 V 16.9%
Centrosolar America EP72 330BW 330.0 W 301.3 W 46.65 V 37.58 V 17.16%
Centrosolar America EP72 335BW 335.0 W 306.0 W 46.83 V 37.9 V 17.42%

How Many Centrosolar America EP72 330BW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America EP72 330BW (46.65 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.65V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.22 V 11 panels 585.4 V 18 panels
-10 C (14 F) 51.76 V 11 panels 569.4 V 19 panels
0 C (32 F) 50.3 V 11 panels 553.3 V 19 panels
25 C (77 F STC) 46.65 V 12 panels 559.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EP72 330BW?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W (330.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.7%
Advance Power API-P330
Advance Power
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EP72 330BW?

Evaluate Centrosolar America EP72 330BW (330.0 W STC, 46.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EP72 330BW reaches 53.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 517 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (517 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EP72 330BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EP72 330BW 8 kW Residential Fit

Needs 25 modules (517 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 301.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EP72 330BW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America EP72 330BW PTC wattage (301.3 W) lower than STC (330.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 301.3 W PTC (91.3% retention) across Centrosolar America EP72 330BW's 1.923 m2 aperture.

Who should skip Centrosolar America EP72 330BW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Centrosolar America EP72 330BW panels (517 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

What is the 1,000 V commercial string limit for Centrosolar America EP72 330BW?

On 1,000 V commercial inverters at -10 C (51.76 V cold Voc), Centrosolar America EP72 330BW fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America EP72 330BW.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls