US Solar USS-QCMI3-72-310 is a 310.0 W STC (279.6 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.94% efficiency, 45.18 V Voc at 25 C, and 50.54 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 279.6 W
- Voc @ 25C
- 45.18 V
- Efficiency
- 15.94%
How Does US Solar USS-QCMI3-72-310 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI3-72-310: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Across 1,407 Multi-c-Si listings from US Solar and peers, US Solar USS-QCMI3-72-310 stands 31.2 W above the 278.8 W Multi-c-Si median and typical 90.2% PTC-to-STC thermal output (279.6 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.18 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does US Solar USS-QCMI3-72-310 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI3-72-310 (310.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define US Solar USS-QCMI3-72-310?
Dataset percentiles tracking US Solar USS-QCMI3-72-310 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for US Solar USS-QCMI3-72-310?
Benchmark highlights for US Solar USS-QCMI3-72-310 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.94% Aperture Efficiency
Power density 159.5 W/m2 (3.97 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.54 V at -10 C (555.9 V string) and 52.07 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.5 m2 (544 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.18 * (1 + (-0.339/100) * (-10 - 25)) = 50.54 V | OCPD = 1.56 * 8.7 = 13.57 A
Inputs from CEC Modules.csv for US Solar USS-QCMI3-72-310: Voc=45.18 V, beta_Voc=-0.339%/C, Isc=8.7 A, STC=310.0 W, Area=1.944 m2.
Result: 11 panels max on 600 V (555.9 V); 26 panels for 8 kW (544 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI3-72-310?
Official CEC datasheet figures for US Solar USS-QCMI3-72-310 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 279.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.3 V / 8.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.94% (1.944 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI3-72-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI3-72-310 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 419 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 544 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 691 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Consolidated US Solar wattage variants sharing the US Solar USS-QCMI3-72-310 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI3-72-300 | 300.0 W | 270.3 W | 44.75 V | 36.45 V | 15.43% |
| US Solar USS-QCMI3-72-305 | 305.0 W | 274.9 W | 44.83 V | 36.53 V | 15.69% |
| US Solar USS-QCMI3-72-310 | 310.0 W | 279.6 W | 45.18 V | 37.3 V | 15.94% |
| US Solar USS-QCMI3-72-315 | 315.0 W | 284.2 W | 45.32 V | 37.58 V | 16.2% |
| US Solar USS-QCMI3-72-320 | 320.0 W | 288.8 W | 45.5 V | 38.0 V | 16.46% |
How Many US Solar USS-QCMI3-72-310 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI3-72-310 (50.54 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.07 V | 11 panels | 572.8 V | 19 panels |
| -10 C (14 F) | 50.54 V | 11 panels | 555.9 V | 19 panels |
| 0 C (32 F) | 49.01 V | 12 panels | 588.1 V | 20 panels |
| 25 C (77 F STC) | 45.18 V | 13 panels | 587.3 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-72-310?
Competing CEC solar panels closest to US Solar USS-QCMI3-72-310 in nameplate wattage and Voc, starting with Centrosolar America DP72 310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-72-310?
Evaluate US Solar USS-QCMI3-72-310 (310.0 W STC, 45.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-72-310 reaches 52.07 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (544 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-72-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI3-72-310 8 kW Residential Fit
Needs 26 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI3-72-310 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMI3-72-310?
Multiplying US Solar USS-QCMI3-72-310's 8.7 A short-circuit current by 1.56 equals 13.57 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can US Solar USS-QCMI3-72-310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.54 V cold Voc at 14 F and handles 8.7 A Isc; string inverters cap US Solar USS-QCMI3-72-310 at 11 panels on 600 V.
Is US Solar USS-QCMI3-72-310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMI3-72-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)