Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6M409T140 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6M409T140 is a 140.0 W STC (125.0 W PTC) Mono-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 14.29% efficiency, 22.03 V Voc at 25 C, and 24.77 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
140.0 W
PTC Wattage
125.0 W
Voc @ 25C
22.03 V
Efficiency
14.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6M409T140 Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN6M409T140 (140.0 W STC) vs. Centrosolar America DP36 140 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,440 across 21,677 CEC solar panels (below all-CEC median; higher than 1.0% of peers), Auxin Solar AXN6M409T140 operates as a compact residential or specialty off-grid module sitting 270.0 W below the 410.0 W Mono-c-Si median. Lower 22.03 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters. With typical 89.3% PTC-to-STC thermal output (125.0 W real-world rating), 58 panels occupy 612 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN6M409T140 Fall Across Listed CEC Models?

Plots Auxin Solar AXN6M409T140 at 140.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6M409T140 (140.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6M4: 140.0 W

What Dataset Percentiles Define Auxin Solar AXN6M409T140?

Benchmarks Auxin Solar AXN6M409T140 on STC wattage, thermal PTC/STC retention, and 14.29 aperture conversion efficiency against CEC peers.

Auxin Solar AXN6M409T140 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6M409T140 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage140.0 WPTC/STC Retention89.3%Module Efficiency14.29%

What Do the Dataset Ranks Show for Auxin Solar AXN6M409T140?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M409T140 by Auxin Solar.

Rank #21,440 / 21,677

140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,636

14.29% Aperture Efficiency

Power density 142.9 W/m2 (5.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.77 V at -10 C (594.5 V string) and 25.56 V at -20 C (23 max).

8 kW Reference Array

58 Panels = 8,120 W STC

Occupies 56.8 m2 (612 sq ft) producing 7,250 W PTC; NEC 690.8 OCPD floor is 12.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.03 * (1 + (-0.356/100) * (-10 - 25)) = 24.77 V | OCPD = 1.56 * 8.23 = 12.84 A

Inputs from CEC Modules.csv for Auxin Solar AXN6M409T140: Voc=22.03 V, beta_Voc=-0.356%/C, Isc=8.23 A, STC=140.0 W, Area=0.98 m2.

Result: 24 panels max on 600 V (594.5 V); 58 panels for 8 kW (612 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6M409T140?

Laboratory test ratings recorded for Auxin Solar AXN6M409T140 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6M409T140.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 140.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 125.0 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.03 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 18.36 V / 7.63 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.356 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.29% (0.98 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6M409T140 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (612 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M409T140.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 43 6.02 kW 454 sq ft $1,507 $2,548
8 kW Class 58 8.12 kW 612 sq ft $2,032 $3,437
10 kW Class 72 10.08 kW 760 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M409T140 under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN6M409T140 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6M409T130 130.0 W 115.8 W 21.6 V 17.96 V 13.27%
Auxin Solar AXN6M409T135 135.0 W 120.4 W 21.58 V 18.22 V 13.78%
Auxin Solar AXN6M409T140 140.0 W 125.0 W 22.03 V 18.36 V 14.29%
Auxin Solar AXN6M409T145 145.0 W 129.6 W 22.46 V 18.36 V 14.8%

How Many Auxin Solar AXN6M409T140 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN6M409T140 (beta_Voc -0.356%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=22.03V and beta_Voc=-0.356%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.56 V 23 panels 587.9 V 39 panels
-10 C (14 F) 24.77 V 24 panels 594.5 V 40 panels
0 C (32 F) 23.99 V 25 panels 599.8 V 41 panels
25 C (77 F STC) 22.03 V 27 panels 594.8 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M409T140?

Closest cross-brand CEC competitors to Auxin Solar AXN6M409T140 matched near 140.0 W STC and 22.03 V Voc, led by Centrosolar America DP36 140.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP36 140
Centrosolar America
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
Solartech Energy ASC-6P-36-140
Solartech Energy
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
US Solar USS-QCMI2-36-140
US Solar
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
APOS Energy AS140
APOS Energy
140.0 W Tie (0 W) 22.33 V 13.69% 89.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M409T140?

Evaluate Auxin Solar AXN6M409T140 (140.0 W STC, 22.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M409T140 reaches 25.56 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 58 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (612 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M409T140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6M409T140 8 kW Residential Fit

Needs 58 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Centrosolar America DP36 140.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 125.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6M409T140 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN6M409T140 panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN6M409T140 cold Voc rises from 22.03 V to 24.77 V (beta_Voc -0.356%/C), capping a 600 V string at 24 panels (594.5 V).

How much roof area does an 8 kW array of Auxin Solar AXN6M409T140 need?

An 8 kW DC system uses 58 Auxin Solar AXN6M409T140 modules (8,120 W STC / 7,250 W PTC), covering roughly 612 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does Auxin Solar AXN6M409T140 compare against Centrosolar America DP36 140?

Auxin Solar AXN6M409T140 outputs 140.0 W STC (22.03 V Voc, rank #21,440 of 21,677), while Centrosolar America DP36 140 delivers 140.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.