Auxin Solar AXN6M409T140 is a 140.0 W STC (125.0 W PTC) Mono-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 14.29% efficiency, 22.03 V Voc at 25 C, and 24.77 V cold Voc at -10 C (24 panels max per 600 V string).
- STC Wattage
- 140.0 W
- PTC Wattage
- 125.0 W
- Voc @ 25C
- 22.03 V
- Efficiency
- 14.29%
How Does Auxin Solar AXN6M409T140 Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXN6M409T140 (140.0 W STC) vs. Centrosolar America DP36 140 across 5,889 CEC Mono-c-Si solar modules.
Ranking #21,440 across 21,677 CEC solar panels (below all-CEC median; higher than 1.0% of peers), Auxin Solar AXN6M409T140 operates as a compact residential or specialty off-grid module sitting 270.0 W below the 410.0 W Mono-c-Si median. Lower 22.03 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters. With typical 89.3% PTC-to-STC thermal output (125.0 W real-world rating), 58 panels occupy 612 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Auxin Solar AXN6M409T140 Fall Across Listed CEC Models?
Plots Auxin Solar AXN6M409T140 at 140.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXN6M409T140?
Benchmarks Auxin Solar AXN6M409T140 on STC wattage, thermal PTC/STC retention, and 14.29 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXN6M409T140?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M409T140 by Auxin Solar.
140.0 W STC · Higher Than 1.0%
140.0 W STC (-245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.29% Aperture Efficiency
Power density 142.9 W/m2 (5.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).
24 Panels Max @ -10 C (600 V)
Cold Voc reaches 24.77 V at -10 C (594.5 V string) and 25.56 V at -20 C (23 max).
58 Panels = 8,120 W STC
Occupies 56.8 m2 (612 sq ft) producing 7,250 W PTC; NEC 690.8 OCPD floor is 12.84 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.03 * (1 + (-0.356/100) * (-10 - 25)) = 24.77 V | OCPD = 1.56 * 8.23 = 12.84 A
Inputs from CEC Modules.csv for Auxin Solar AXN6M409T140: Voc=22.03 V, beta_Voc=-0.356%/C, Isc=8.23 A, STC=140.0 W, Area=0.98 m2.
Result: 24 panels max on 600 V (594.5 V); 58 panels for 8 kW (612 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN6M409T140?
Laboratory test ratings recorded for Auxin Solar AXN6M409T140 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 125.0 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 18.36 V / 7.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.356 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.29% (0.98 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXN6M409T140 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (612 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M409T140.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 43 | 6.02 kW | 454 sq ft | $1,507 | $2,548 |
| 8 kW Class | 58 | 8.12 kW | 612 sq ft | $2,032 | $3,437 |
| 10 kW Class | 72 | 10.08 kW | 760 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M409T140 under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN6M409T130 | 130.0 W | 115.8 W | 21.6 V | 17.96 V | 13.27% |
| Auxin Solar AXN6M409T135 | 135.0 W | 120.4 W | 21.58 V | 18.22 V | 13.78% |
| Auxin Solar AXN6M409T140 | 140.0 W | 125.0 W | 22.03 V | 18.36 V | 14.29% |
| Auxin Solar AXN6M409T145 | 145.0 W | 129.6 W | 22.46 V | 18.36 V | 14.8% |
How Many Auxin Solar AXN6M409T140 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXN6M409T140 (beta_Voc -0.356%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.56 V | 23 panels | 587.9 V | 39 panels |
| -10 C (14 F) | 24.77 V | 24 panels | 594.5 V | 40 panels |
| 0 C (32 F) | 23.99 V | 25 panels | 599.8 V | 41 panels |
| 25 C (77 F STC) | 22.03 V | 27 panels | 594.8 V | 45 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M409T140?
Closest cross-brand CEC competitors to Auxin Solar AXN6M409T140 matched near 140.0 W STC and 22.03 V Voc, led by Centrosolar America DP36 140.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP36 140 Centrosolar America |
140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| Solartech Energy ASC-6P-36-140 Solartech Energy |
140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| US Solar USS-QCMI2-36-140 US Solar |
140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| APOS Energy AS140 APOS Energy |
140.0 W | Tie (0 W) | 22.33 V | 13.69% | 89.6% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M409T140?
Evaluate Auxin Solar AXN6M409T140 (140.0 W STC, 22.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M409T140 reaches 25.56 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (612 sq ft).
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M409T140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN6M409T140 8 kW Residential Fit
Needs 58 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Centrosolar America DP36 140.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 125.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN6M409T140 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Auxin Solar AXN6M409T140 panels fit on a 600 V winter solar string?
At -10 C (14 F), Auxin Solar AXN6M409T140 cold Voc rises from 22.03 V to 24.77 V (beta_Voc -0.356%/C), capping a 600 V string at 24 panels (594.5 V).
How much roof area does an 8 kW array of Auxin Solar AXN6M409T140 need?
An 8 kW DC system uses 58 Auxin Solar AXN6M409T140 modules (8,120 W STC / 7,250 W PTC), covering roughly 612 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Auxin Solar AXN6M409T140 compare against Centrosolar America DP36 140?
Auxin Solar AXN6M409T140 outputs 140.0 W STC (22.03 V Voc, rank #21,440 of 21,677), while Centrosolar America DP36 140 delivers 140.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)