APOS Energy AP135 — CEC Solar Module Specifications

Manufacturer: APOS Energy Registry: CEC Verified Engineering Specification

APOS Energy AP135 is a 135.0 W STC (119.9 W PTC) Multi-c-Si solar module ranking #21,456 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.2% efficiency, 22.21 V Voc at 25 C, and 24.51 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
135.0 W
PTC Wattage
119.9 W
Voc @ 25C
22.21 V
Efficiency
13.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does APOS Energy AP135 Compare Against Peer CEC Listings?

How APOS Energy APOS Energy AP135 handles rooftop heat (119.9 W PTC), 8 kW sizing, and cold winter string voltage.

APOS Energy builds the APOS Energy AP135 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 132.0 W/m2 (6.71 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-135G6S (135.0 W), this model holds typical 88.8% PTC-to-STC thermal output (119.9 W real-world rating). Lower 22.21 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.39 A overcurrent floor served by a 15 A breaker.

Where Does APOS Energy AP135 Fall Across Listed CEC Models?

Where APOS Energy AP135 (135.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where APOS Energy AP135 (135.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAPOS Energy AP135: 135.0 W

What Dataset Percentiles Define APOS Energy AP135?

Percentile placement of APOS Energy AP135 across power density (132.0 W/m2), thermal retention, and nameplate STC wattage.

APOS Energy AP135 Engineering BenchmarksPercentile comparison of APOS Energy AP135 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage135.0 WPTC/STC Retention88.8%Module Efficiency13.2%

What Do the Dataset Ranks Show for APOS Energy AP135?

Four critical engineering numbers homeowners and solar installers check first when reviewing APOS Energy AP135 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #21,456 / 21,677

135.0 W STC · Higher Than 1.0%

135.0 W STC (-250.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,354

13.2% Aperture Efficiency

Power density 132.0 W/m2 (6.71 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.51 V at -10 C (588.2 V string) and 25.17 V at -20 C (23 max).

8 kW Reference Array

60 Panels = 8,100 W STC

Occupies 61.4 m2 (661 sq ft) producing 7,194 W PTC; NEC 690.8 OCPD floor is 12.39 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.21 * (1 + (-0.296/100) * (-10 - 25)) = 24.51 V | OCPD = 1.56 * 7.94 = 12.39 A

Inputs from CEC Modules.csv for APOS Energy AP135: Voc=22.21 V, beta_Voc=-0.296%/C, Isc=7.94 A, STC=135.0 W, Area=1.023 m2.

Result: 24 panels max on 600 V (588.2 V); 60 panels for 8 kW (661 sq ft).

What Are the Published CEC Specifications for APOS Energy AP135?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for APOS Energy AP135.

Official California Energy Commission (NREL SAM) test parameters for APOS Energy AP135.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 135.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 119.9 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.94 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.58 V / 7.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.2% (1.023 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many APOS Energy AP135 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using APOS Energy AP135 (135.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 45 6.08 kW 496 sq ft $1,522 $2,573
8 kW Class 60 8.1 kW 661 sq ft $2,027 $3,428
10 kW Class 75 10.12 kW 826 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?

All closely matched APOS Energy wattages and cosmetic trims sharing the APOS Energy AP135 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the APOS Energy AP135 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
APOS Energy AP130 130.0 W 115.4 W 22.07 V 17.38 V 12.71%
APOS Energy AP135 135.0 W 119.9 W 22.21 V 17.58 V 13.2%
APOS Energy AP140 140.0 W 124.5 W 22.39 V 17.93 V 13.69%

How Many APOS Energy AP135 Modules Fit in a Cold-Weather String?

Maximum series module counts for APOS Energy AP135 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=22.21V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.17 V 23 panels 578.9 V 39 panels
-10 C (14 F) 24.51 V 24 panels 588.2 V 40 panels
0 C (32 F) 23.85 V 25 panels 596.2 V 41 panels
25 C (77 F STC) 22.21 V 27 panels 599.7 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP135?

Alternative CEC solar modules from competing brands near APOS Energy AP135 (135.0 W), including Gintung Energy ASEC-135G6S. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-135G6S
Gintung Energy
135.0 W Tie (0 W) 22.15 V 13.74% 89.6%
Gintung Energy ASEC-135G6M
Gintung Energy
135.0 W Tie (0 W) 22.1 V 13.74% 89.3%
United Renewable Energy Co Ltd D6P135A1F
United Renewable Energy Co Ltd
135.0 W Tie (0 W) 22.1 V 13.74% 89.3%
Centrosolar America DP36 140
Centrosolar America
140.0 W +5.0 W 22.15 V 13.85% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for APOS Energy AP135?

Evaluate APOS Energy AP135 (135.0 W STC, 22.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP135 reaches 25.17 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 60 panels for an 8 kW build require 661 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 60 panels (661 sq ft).
  • 2026 tax credit baseline: cash residential installs of APOS Energy AP135 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

APOS Energy AP135 8 kW Residential Fit

Needs 60 modules (661 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Gintung Energy ASEC-135G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 119.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for APOS Energy AP135 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for APOS Energy AP135?

Multiplying APOS Energy AP135's 7.94 A short-circuit current by 1.56 equals 12.39 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can APOS Energy AP135 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 24.51 V cold Voc at 14 F and handles 7.94 A Isc; string inverters cap APOS Energy AP135 at 24 panels on 600 V.

Is APOS Energy AP135 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of APOS Energy AP135 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.