APOS Energy AS210 — CEC Solar Module Specifications

Manufacturer: APOS Energy Registry: CEC Verified Engineering Specification

APOS Energy AS210 is a 210.0 W STC (188.3 W PTC) Mono-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 14.0% efficiency, 33.5 V Voc at 25 C, and 36.88 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
210.0 W
PTC Wattage
188.3 W
Voc @ 25C
33.5 V
Efficiency
14.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does APOS Energy AS210 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for APOS Energy AS210 (Mono-c-Si) residential solar systems.

APOS Energy AS210 delivers 140.0 W/m2 (5.91 percentage points below 19.91% CEC median) and typical 89.7% PTC-to-STC thermal output (188.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (630 sq ft). At -4 F (-20 C), string voltage climbs to 37.84 V per unit, capping 600 V circuits at 15 panels. Compare specs directly with Centrosolar America DP54 210 (210.0 W).

Where Does APOS Energy AS210 Fall Across Listed CEC Models?

Comparison of APOS Energy AS210 (210.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where APOS Energy AS210 (210.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAPOS Energy AS210: 210.0 W

What Dataset Percentiles Define APOS Energy AS210?

Relative ranking of APOS Energy AS210 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

APOS Energy AS210 Engineering BenchmarksPercentile comparison of APOS Energy AS210 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage210.0 WPTC/STC Retention89.7%Module Efficiency14.0%

What Do the Dataset Ranks Show for APOS Energy AS210?

Summary of APOS Energy AS210 output rank, 8 kW array size (39 panels), efficiency rating, and 600 V string limit.

Rank #20,916 / 21,677

210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,901

14.0% Aperture Efficiency

Power density 140.0 W/m2 (5.91 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.88 V at -10 C (590.1 V string) and 37.84 V at -20 C (15 max).

8 kW Reference Array

39 Panels = 8,190 W STC

Occupies 58.5 m2 (630 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 13.28 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.5 * (1 + (-0.288/100) * (-10 - 25)) = 36.88 V | OCPD = 1.56 * 8.51 = 13.28 A

Inputs from CEC Modules.csv for APOS Energy AS210: Voc=33.5 V, beta_Voc=-0.288%/C, Isc=8.51 A, STC=210.0 W, Area=1.5 m2.

Result: 16 panels max on 600 V (590.1 V); 39 panels for 8 kW (630 sq ft).

What Are the Published CEC Specifications for APOS Energy AS210?

Complete CEC test sheet for APOS Energy AS210 including Isc (8.51 A), Voc (33.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for APOS Energy AS210.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 210.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 188.3 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.51 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.63 V / 7.84 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.288 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.0% (1.5 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many APOS Energy AS210 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using APOS Energy AS210.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 29 6.09 kW 468 sq ft $1,524 $2,577
8 kW Class 39 8.19 kW 630 sq ft $2,050 $3,466
10 kW Class 48 10.08 kW 775 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?

Related APOS Energy power steps and black/silver trims consolidated into this APOS Energy AS210 series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the APOS Energy AS210 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
APOS Energy AS200 200.0 W 179.1 W 32.97 V 26.18 V 13.33%
APOS Energy AS205 205.0 W 183.7 W 33.34 V 26.38 V 13.67%
APOS Energy AS210 210.0 W 188.3 W 33.5 V 26.63 V 14.0%
APOS Energy AS215 215.0 W 192.9 W 33.66 V 26.89 V 14.33%

How Many APOS Energy AS210 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for APOS Energy AS210 (33.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=33.5V and beta_Voc=-0.288%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 37.84 V 15 panels 567.6 V 26 panels
-10 C (14 F) 36.88 V 16 panels 590.1 V 27 panels
0 C (32 F) 35.91 V 16 panels 574.6 V 27 panels
25 C (77 F STC) 33.5 V 17 panels 569.5 V 29 panels

Which Cross-Brand Solar Modules Compare Closest to APOS Energy AS210?

Four comparable CEC modules such as Centrosolar America DP54 210 (210.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP54 210
Centrosolar America
210.0 W Tie (0 W) 33.23 V 14.16% 88.4%
Gintung Energy ASEC-205G6M
Gintung Energy
205.0 W -5.0 W 33.58 V 14.57% 88.5%
Gintung Energy ASEC-205G6S
Gintung Energy
205.0 W -5.0 W 33.64 V 14.57% 89.6%
Guangdong Golden Glass Technologies GG205M2-27/1482x992
Guangdong Golden Glass Technologies
205.0 W -5.0 W 33.2 V 13.94% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for APOS Energy AS210?

Evaluate APOS Energy AS210 (210.0 W STC, 33.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AS210 reaches 37.84 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 39 panels for an 8 kW build require 630 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (630 sq ft).
  • 2026 tax credit baseline: cash residential installs of APOS Energy AS210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

APOS Energy AS210 8 kW Residential Fit

Needs 39 modules (630 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 210.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 188.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for APOS Energy AS210 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many APOS Energy AS210 panels fit on a 600 V winter solar string?

At -10 C (14 F), APOS Energy AS210 cold Voc rises from 33.5 V to 36.88 V (beta_Voc -0.288%/C), capping a 600 V string at 16 panels (590.1 V).

How much roof area does an 8 kW array of APOS Energy AS210 need?

An 8 kW DC system uses 39 APOS Energy AS210 modules (8,190 W STC / 7,344 W PTC), covering roughly 630 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does APOS Energy AS210 compare against Centrosolar America DP54 210?

APOS Energy AS210 outputs 210.0 W STC (33.5 V Voc, rank #20,916 of 21,677), while Centrosolar America DP54 210 delivers 210.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.