Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DP54 210 is a 210.0 W STC (185.7 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 14.16% efficiency, 33.23 V Voc at 25 C, and 37.42 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
210.0 W
PTC Wattage
185.7 W
Voc @ 25C
33.23 V
Efficiency
14.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DP54 210 Compare Against Peer CEC Listings?

How Centrosolar America Centrosolar America DP54 210 handles rooftop heat (185.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Centrosolar America DP54 210 exhibits 8.5 A short-circuit current, requiring a 13.26 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,916 of 21,677 (68.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.8 m2 for an 8 kW system (48 panels for 10 kW). Lower 33.23 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.

Where Does Centrosolar America DP54 210 Fall Across Listed CEC Models?

Where Centrosolar America DP54 210 (210.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DP54 210 (210.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 210.0 W

What Dataset Percentiles Define Centrosolar America DP54 210?

Percentile placement of Centrosolar America DP54 210 across power density (141.6 W/m2), thermal retention, and nameplate STC wattage.

Centrosolar America DP54 210 Engineering BenchmarksPercentile comparison of Centrosolar America DP54 210 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage210.0 WPTC/STC Retention88.4%Module Efficiency14.16%

What Do the Dataset Ranks Show for Centrosolar America DP54 210?

Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America DP54 210 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #20,916 / 21,677

210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,764

14.16% Aperture Efficiency

Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.42 V at -10 C (598.7 V string) and 38.61 V at -20 C (15 max).

8 kW Reference Array

39 Panels = 8,190 W STC

Occupies 57.8 m2 (623 sq ft) producing 7,242 W PTC; NEC 690.8 OCPD floor is 13.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.23 * (1 + (-0.36/100) * (-10 - 25)) = 37.42 V | OCPD = 1.56 * 8.5 = 13.26 A

Inputs from CEC Modules.csv for Centrosolar America DP54 210: Voc=33.23 V, beta_Voc=-0.36%/C, Isc=8.5 A, STC=210.0 W, Area=1.483 m2.

Result: 16 panels max on 600 V (598.7 V); 39 panels for 8 kW (623 sq ft).

What Are the Published CEC Specifications for Centrosolar America DP54 210?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America DP54 210.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP54 210.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 210.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 185.7 W (88.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.23 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.25 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.16% (1.483 m2) Array roof footprint density
Cell Count & Technology 54 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America DP54 210 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America DP54 210 (210.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 29 6.09 kW 463 sq ft $1,524 $2,577
8 kW Class 39 8.19 kW 623 sq ft $2,050 $3,466
10 kW Class 48 10.08 kW 766 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

All closely matched Centrosolar America wattages and cosmetic trims sharing the Centrosolar America DP54 210 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Centrosolar America DP54 210 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DP54 200 200.0 W 176.6 W 32.8 V 25.25 V 13.49%
Centrosolar America DP54 205 205.0 W 181.2 W 33.01 V 25.72 V 13.82%
Centrosolar America DP54 210 210.0 W 185.7 W 33.23 V 26.25 V 14.16%
Centrosolar America DP54 215 215.0 W 190.3 W 33.44 V 26.81 V 14.5%
Centrosolar America DP54 220 220.0 W 194.8 W 33.66 V 27.33 V 14.83%

How Many Centrosolar America DP54 210 Modules Fit in a Cold-Weather String?

Maximum series module counts for Centrosolar America DP54 210 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=33.23V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 38.61 V 15 panels 579.1 V 25 panels
-10 C (14 F) 37.42 V 16 panels 598.7 V 26 panels
0 C (32 F) 36.22 V 16 panels 579.5 V 27 panels
25 C (77 F STC) 33.23 V 18 panels 598.1 V 30 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP54 210?

Alternative CEC solar modules from competing brands near Centrosolar America DP54 210 (210.0 W), including APOS Energy AS210.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
APOS Energy AS210
APOS Energy
210.0 W Tie (0 W) 33.5 V 14.0% 89.7%
Guangdong Golden Glass Technologies GG205M2-27/1482x992
Guangdong Golden Glass Technologies
205.0 W -5.0 W 33.2 V 13.94% 89.9%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M205
Hanwha Qcells (Qidong) Co Ltd
205.0 W -5.0 W 33.1 V 13.72% 88.9%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M205B
Hanwha Qcells (Qidong) Co Ltd
205.0 W -5.0 W 33.1 V 13.72% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DP54 210?

Evaluate Centrosolar America DP54 210 (210.0 W STC, 33.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP54 210 reaches 38.61 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 39 panels for an 8 kW build require 623 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (623 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DP54 210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DP54 210 8 kW Residential Fit

Needs 39 modules (623 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare APOS Energy AS210.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 185.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP54 210 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America DP54 210 PTC wattage (185.7 W) lower than STC (210.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 185.7 W PTC (88.4% retention) across Centrosolar America DP54 210's 1.483 m2 aperture.

Who should skip Centrosolar America DP54 210 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 39 Centrosolar America DP54 210 panels (623 sq ft) leave unusable roof gaps vs. APOS Energy AS210.

What is the 1,000 V commercial string limit for Centrosolar America DP54 210?

On 1,000 V commercial inverters at -10 C (37.42 V cold Voc), Centrosolar America DP54 210 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America DP54 210.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.