APOS Energy AS235 is a 235.0 W STC (210.7 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.17% efficiency, 37.34 V Voc at 25 C, and 41.1 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 210.7 W
- Voc @ 25C
- 37.34 V
- Efficiency
- 14.17%
How Does APOS Energy AS235 Compare Against Peer CEC Listings?
How APOS Energy APOS Energy AS235 handles rooftop heat (210.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, APOS Energy AS235 exhibits 8.55 A short-circuit current, requiring a 13.34 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (175.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 58.1 m2 for an 8 kW system (43 panels for 10 kW). Lower 37.34 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does APOS Energy AS235 Fall Across Listed CEC Models?
Where APOS Energy AS235 (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define APOS Energy AS235?
Percentile placement of APOS Energy AS235 across power density (141.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for APOS Energy AS235?
Four critical engineering numbers homeowners and solar installers check first when reviewing APOS Energy AS235 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.17% Aperture Efficiency
Power density 141.7 W/m2 (5.74 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.1 V at -10 C (575.4 V string) and 42.18 V at -20 C (14 max).
35 Panels = 8,225 W STC
Occupies 58.1 m2 (625 sq ft) producing 7,374 W PTC; NEC 690.8 OCPD floor is 13.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.34 * (1 + (-0.288/100) * (-10 - 25)) = 41.1 V | OCPD = 1.56 * 8.55 = 13.34 A
Inputs from CEC Modules.csv for APOS Energy AS235: Voc=37.34 V, beta_Voc=-0.288%/C, Isc=8.55 A, STC=235.0 W, Area=1.659 m2.
Result: 14 panels max on 600 V (575.4 V); 35 panels for 8 kW (625 sq ft).
What Are the Published CEC Specifications for APOS Energy AS235?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for APOS Energy AS235.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 210.7 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.76 V / 7.86 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.288 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.17% (1.659 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many APOS Energy AS235 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using APOS Energy AS235 (235.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 464 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 625 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 768 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?
All closely matched APOS Energy wattages and cosmetic trims sharing the APOS Energy AS235 architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| APOS Energy AS225 | 225.0 W | 201.6 W | 36.99 V | 29.31 V | 13.56% |
| APOS Energy AS230 | 230.0 W | 206.1 W | 37.11 V | 29.42 V | 13.86% |
| APOS Energy AS235 | 235.0 W | 210.7 W | 37.34 V | 29.76 V | 14.17% |
| APOS Energy AS240 | 240.0 W | 215.4 W | 37.52 V | 30.05 V | 14.47% |
How Many APOS Energy AS235 Modules Fit in a Cold-Weather String?
Maximum series module counts for APOS Energy AS235 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.18 V | 14 panels | 590.5 V | 23 panels |
| -10 C (14 F) | 41.1 V | 14 panels | 575.4 V | 24 panels |
| 0 C (32 F) | 40.03 V | 14 panels | 560.4 V | 24 panels |
| 25 C (77 F STC) | 37.34 V | 16 panels | 597.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to APOS Energy AS235?
Alternative CEC solar modules from competing brands near APOS Energy AS235 (235.0 W), including Gintech Energy GTE 235M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintech Energy GTE 235M Gintech Energy |
235.0 W | Tie (0 W) | 37.32 V | 13.97% | 89.5% |
| Advance Power API-M235 Advance Power |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| Auxin Solar AXN6M610T235 Auxin Solar |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| AXITEC AC-235P/156-60S AXITEC |
235.0 W | Tie (0 W) | 37.16 V | 14.48% | 90.0% |
What Are the Design Limits and Best-Fit Uses for APOS Energy AS235?
Evaluate APOS Energy AS235 (235.0 W STC, 37.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AS235 reaches 42.18 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 625 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (625 sq ft).
- 2026 tax credit baseline: cash residential installs of APOS Energy AS235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
APOS Energy AS235 8 kW Residential Fit
Needs 35 modules (625 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintech Energy GTE 235M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for APOS Energy AS235 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is APOS Energy AS235 PTC wattage (210.7 W) lower than STC (235.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 210.7 W PTC (89.7% retention) across APOS Energy AS235's 1.659 m2 aperture.
Who should skip APOS Energy AS235 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 APOS Energy AS235 panels (625 sq ft) leave unusable roof gaps vs. Gintech Energy GTE 235M.
What is the 1,000 V commercial string limit for APOS Energy AS235?
On 1,000 V commercial inverters at -10 C (41.1 V cold Voc), APOS Energy AS235 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting APOS Energy AS235.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)