AXITEC AC-235P/156-60S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-235P/156-60S is a 235.0 W STC (211.5 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.48% efficiency, 37.16 V Voc at 25 C, and 41.7 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
211.5 W
Voc @ 25C
37.16 V
Efficiency
14.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-235P/156-60S Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-235P/156-60S handles rooftop heat (211.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AXITEC AC-235P/156-60S exhibits 8.32 A short-circuit current, requiring a 12.98 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (43.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 56.8 m2 for an 8 kW system (43 panels for 10 kW). Lower 37.16 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does AXITEC AC-235P/156-60S Fall Across Listed CEC Models?

Where AXITEC AC-235P/156-60S (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-235P/156-60S (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-235P/156: 235.0 W

What Dataset Percentiles Define AXITEC AC-235P/156-60S?

Percentile placement of AXITEC AC-235P/156-60S across power density (144.8 W/m2), thermal retention, and nameplate STC wattage.

AXITEC AC-235P/156-60S Engineering BenchmarksPercentile comparison of AXITEC AC-235P/156-60S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.0%Module Efficiency14.48%

What Do the Dataset Ranks Show for AXITEC AC-235P/156-60S?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-235P/156-60S specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,447

14.48% Aperture Efficiency

Power density 144.8 W/m2 (5.43 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.7 V at -10 C (583.8 V string) and 43.0 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.8 m2 (611 sq ft) producing 7,402 W PTC; NEC 690.8 OCPD floor is 12.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.16 * (1 + (-0.349/100) * (-10 - 25)) = 41.7 V | OCPD = 1.56 * 8.32 = 12.98 A

Inputs from CEC Modules.csv for AXITEC AC-235P/156-60S: Voc=37.16 V, beta_Voc=-0.349%/C, Isc=8.32 A, STC=235.0 W, Area=1.623 m2.

Result: 14 panels max on 600 V (583.8 V); 35 panels for 8 kW (611 sq ft).

What Are the Published CEC Specifications for AXITEC AC-235P/156-60S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-235P/156-60S.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-235P/156-60S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 211.5 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.16 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.49 V / 7.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.349 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.48% (1.623 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-235P/156-60S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-235P/156-60S (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 454 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 611 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 751 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-235P/156-60S architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the AXITEC AC-235P/156-60S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-225P/156-60S 225.0 W 202.3 W 36.95 V 29.22 V 13.86%
AXITEC AC-230P/156-60S 230.0 W 206.9 W 37.05 V 29.34 V 14.17%
AXITEC AC-235P/156-60S 235.0 W 211.5 W 37.16 V 29.49 V 14.48%
AXITEC AC-240P/156-60S 240.0 W 216.1 W 37.25 V 29.67 V 14.79%
AXITEC AC-245P/156-60S 245.0 W 220.8 W 37.34 V 29.88 V 15.1%

How Many AXITEC AC-235P/156-60S Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-235P/156-60S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.16V and beta_Voc=-0.349%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.0 V 13 panels 559.0 V 23 panels
-10 C (14 F) 41.7 V 14 panels 583.8 V 23 panels
0 C (32 F) 40.4 V 14 panels 565.6 V 24 panels
25 C (77 F STC) 37.16 V 16 panels 594.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-235P/156-60S?

Alternative CEC solar modules from competing brands near AXITEC AC-235P/156-60S (235.0 W), including Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Gintech Energy GTE 235M
Gintech Energy
235.0 W Tie (0 W) 37.32 V 13.97% 89.5%
Centrosolar America DP60 235
Centrosolar America
235.0 W Tie (0 W) 36.98 V 14.33% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-235P/156-60S?

Evaluate AXITEC AC-235P/156-60S (235.0 W STC, 37.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-235P/156-60S reaches 43.0 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 611 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (611 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-235P/156-60S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-235P/156-60S 8 kW Residential Fit

Needs 35 modules (611 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-235P/156-60S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-235P/156-60S PTC wattage (211.5 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 211.5 W PTC (90.0% retention) across AXITEC AC-235P/156-60S's 1.623 m2 aperture.

Who should skip AXITEC AC-235P/156-60S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 AXITEC AC-235P/156-60S panels (611 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

What is the 1,000 V commercial string limit for AXITEC AC-235P/156-60S?

On 1,000 V commercial inverters at -10 C (41.7 V cold Voc), AXITEC AC-235P/156-60S fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-235P/156-60S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.