Gintech Energy GTE 235M is a 235.0 W STC (210.3 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 13.97% efficiency, 37.32 V Voc at 25 C, and 42.15 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 210.3 W
- Voc @ 25C
- 37.32 V
- Efficiency
- 13.97%
How Does Gintech Energy GTE 235M Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintech Energy GTE 235M (Multi-c-Si) residential solar systems.
Homeowners evaluating Gintech Energy GTE 235M need 26 panels for 6 kW or 35 panels (634 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (634 sq ft). Under NEC 690.7(A), beta_Voc (-0.37%/C) pushes open-circuit voltage to 42.15 V at 14 F and 43.53 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintech Energy GTE 235M Fall Across Listed CEC Models?
Comparison of Gintech Energy GTE 235M (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Gintech Energy GTE 235M?
Relative ranking of Gintech Energy GTE 235M across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Gintech Energy GTE 235M?
Summary of Gintech Energy GTE 235M output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.97% Aperture Efficiency
Power density 139.7 W/m2 (5.94 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.15 V at -10 C (590.1 V string) and 43.53 V at -20 C (13 max).
35 Panels = 8,225 W STC
Occupies 58.9 m2 (634 sq ft) producing 7,360 W PTC; NEC 690.8 OCPD floor is 13.12 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.32 * (1 + (-0.37/100) * (-10 - 25)) = 42.15 V | OCPD = 1.56 * 8.41 = 13.12 A
Inputs from CEC Modules.csv for Gintech Energy GTE 235M: Voc=37.32 V, beta_Voc=-0.37%/C, Isc=8.41 A, STC=235.0 W, Area=1.682 m2.
Result: 14 panels max on 600 V (590.1 V); 35 panels for 8 kW (634 sq ft).
What Are the Published CEC Specifications for Gintech Energy GTE 235M?
Complete CEC test sheet for Gintech Energy GTE 235M including Isc (8.41 A), Voc (37.32 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 210.3 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.54 V / 7.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.37 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.97% (1.682 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintech Energy GTE 235M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintech Energy GTE 235M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 471 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 634 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 779 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Gintech Energy Series?
Related Gintech Energy power steps and black/silver trims consolidated into this Gintech Energy GTE 235M series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintech Energy GTE 225M | 225.0 W | 201.1 W | 36.66 V | 30.0 V | 13.38% |
| Gintech Energy GTE 230M | 230.0 W | 205.7 W | 36.9 V | 30.3 V | 13.68% |
| Gintech Energy GTE 235M | 235.0 W | 210.3 W | 37.32 V | 30.54 V | 13.97% |
| Gintech Energy GTE 240M | 240.0 W | 214.9 W | 37.5 V | 30.72 V | 14.27% |
How Many Gintech Energy GTE 235M Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Gintech Energy GTE 235M (37.32 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.53 V | 13 panels | 565.9 V | 22 panels |
| -10 C (14 F) | 42.15 V | 14 panels | 590.1 V | 23 panels |
| 0 C (32 F) | 40.77 V | 14 panels | 570.8 V | 24 panels |
| 25 C (77 F STC) | 37.32 V | 16 panels | 597.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintech Energy GTE 235M?
Four comparable CEC modules such as APOS Energy AS235 (235.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| APOS Energy AS235 APOS Energy |
235.0 W | Tie (0 W) | 37.34 V | 14.17% | 89.7% |
| AXITEC AC-235P/156-60S AXITEC |
235.0 W | Tie (0 W) | 37.16 V | 14.48% | 90.0% |
| Advance Power API-M235 Advance Power |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| Auxin Solar AXN6M610T235 Auxin Solar |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Gintech Energy GTE 235M?
Evaluate Gintech Energy GTE 235M (235.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintech Energy GTE 235M reaches 43.53 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 634 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (634 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintech Energy GTE 235M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintech Energy GTE 235M 8 kW Residential Fit
Needs 35 modules (634 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare APOS Energy AS235.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintech Energy GTE 235M by Gintech Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintech Energy GTE 235M PTC wattage (210.3 W) lower than STC (235.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 210.3 W PTC (89.5% retention) across Gintech Energy GTE 235M's 1.682 m2 aperture.
Who should skip Gintech Energy GTE 235M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Gintech Energy GTE 235M panels (634 sq ft) leave unusable roof gaps vs. APOS Energy AS235.
What is the 1,000 V commercial string limit for Gintech Energy GTE 235M?
On 1,000 V commercial inverters at -10 C (42.15 V cold Voc), Gintech Energy GTE 235M fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintech Energy GTE 235M.