Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DP60 235 is a 235.0 W STC (211.4 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.33% efficiency, 36.98 V Voc at 25 C, and 41.26 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
211.4 W
Voc @ 25C
36.98 V
Efficiency
14.33%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DP60 235 Compare Against Peer CEC Listings?

How Centrosolar America Centrosolar America DP60 235 handles rooftop heat (211.4 W PTC), 8 kW sizing, and cold winter string voltage.

Centrosolar America builds the Centrosolar America DP60 235 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 143.3 W/m2 (5.58 percentage points below 19.91% CEC median). Compared against Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q (235.0 W), this model holds typical 90.0% PTC-to-STC thermal output (211.4 W real-world rating). Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.29 A overcurrent floor served by a 15 A breaker.

Where Does Centrosolar America DP60 235 Fall Across Listed CEC Models?

Where Centrosolar America DP60 235 (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DP60 235 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 235.0 W

What Dataset Percentiles Define Centrosolar America DP60 235?

Percentile placement of Centrosolar America DP60 235 across power density (143.3 W/m2), thermal retention, and nameplate STC wattage.

Centrosolar America DP60 235 Engineering BenchmarksPercentile comparison of Centrosolar America DP60 235 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.0%Module Efficiency14.33%

What Do the Dataset Ranks Show for Centrosolar America DP60 235?

Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America DP60 235 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,596

14.33% Aperture Efficiency

Power density 143.3 W/m2 (5.58 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.26 V at -10 C (577.6 V string) and 42.49 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.4 m2 (618 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 13.29 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.98 * (1 + (-0.331/100) * (-10 - 25)) = 41.26 V | OCPD = 1.56 * 8.52 = 13.29 A

Inputs from CEC Modules.csv for Centrosolar America DP60 235: Voc=36.98 V, beta_Voc=-0.331%/C, Isc=8.52 A, STC=235.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (577.6 V); 35 panels for 8 kW (618 sq ft).

What Are the Published CEC Specifications for Centrosolar America DP60 235?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America DP60 235.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP60 235.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 211.4 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.3 V / 8.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.331 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.33% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America DP60 235 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America DP60 235 (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 459 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 618 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 759 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

All closely matched Centrosolar America wattages and cosmetic trims sharing the Centrosolar America DP60 235 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Centrosolar America DP60 235 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DP60 225 225.0 W 202.2 W 36.4 V 28.2 V 13.72%
Centrosolar America DP60 230 230.0 W 206.8 W 36.68 V 28.75 V 14.03%
Centrosolar America DP60 235 235.0 W 211.4 W 36.98 V 29.3 V 14.33%
Centrosolar America DP60 240 240.0 W 216.0 W 37.16 V 29.81 V 14.64%
Centrosolar America DP60 245 245.0 W 220.6 W 37.4 V 30.32 V 14.94%

How Many Centrosolar America DP60 235 Modules Fit in a Cold-Weather String?

Maximum series module counts for Centrosolar America DP60 235 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.98V and beta_Voc=-0.331%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.49 V 14 panels 594.9 V 23 panels
-10 C (14 F) 41.26 V 14 panels 577.6 V 24 panels
0 C (32 F) 40.04 V 14 panels 560.6 V 24 panels
25 C (77 F STC) 36.98 V 16 panels 591.7 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP60 235?

Alternative CEC solar modules from competing brands near Centrosolar America DP60 235 (235.0 W), including Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
CSI Solar Co Ltd CS6P-235P
CSI Solar Co Ltd
235.0 W Tie (0 W) 36.9 V 15.17% 90.9%
CSI Solar Co Ltd CS6P-235PX
CSI Solar Co Ltd
235.0 W Tie (0 W) 36.9 V 14.61% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DP60 235?

Evaluate Centrosolar America DP60 235 (235.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP60 235 reaches 42.49 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 618 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (618 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DP60 235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DP60 235 8 kW Residential Fit

Needs 35 modules (618 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP60 235 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America DP60 235?

Multiplying Centrosolar America DP60 235's 8.52 A short-circuit current by 1.56 equals 13.29 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America DP60 235 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.26 V cold Voc at 14 F and handles 8.52 A Isc; string inverters cap Centrosolar America DP60 235 at 14 panels on 600 V.

Is Centrosolar America DP60 235 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP60 235 rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.