APOS Energy AP230 is a 230.0 W STC (204.6 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 13.86% efficiency, 37.32 V Voc at 25 C, and 41.19 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 230.0 W
- PTC Wattage
- 204.6 W
- Voc @ 25C
- 37.32 V
- Efficiency
- 13.86%
How Does APOS Energy AP230 Compare Against Peer CEC Listings?
How APOS Energy APOS Energy AP230 handles rooftop heat (204.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, APOS Energy AP230 exhibits 8.05 A short-circuit current, requiring a 12.56 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,522 of 21,677 (48.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 58.1 m2 for an 8 kW system (44 panels for 10 kW). Lower 37.32 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does APOS Energy AP230 Fall Across Listed CEC Models?
Where APOS Energy AP230 (230.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define APOS Energy AP230?
Percentile placement of APOS Energy AP230 across power density (138.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for APOS Energy AP230?
Four critical engineering numbers homeowners and solar installers check first when reviewing APOS Energy AP230 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
230.0 W STC · Higher Than 4.7%
230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.86% Aperture Efficiency
Power density 138.6 W/m2 (6.05 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.19 V at -10 C (576.7 V string) and 42.29 V at -20 C (14 max).
35 Panels = 8,050 W STC
Occupies 58.1 m2 (625 sq ft) producing 7,161 W PTC; NEC 690.8 OCPD floor is 12.56 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.32 * (1 + (-0.296/100) * (-10 - 25)) = 41.19 V | OCPD = 1.56 * 8.05 = 12.56 A
Inputs from CEC Modules.csv for APOS Energy AP230: Voc=37.32 V, beta_Voc=-0.296%/C, Isc=8.05 A, STC=230.0 W, Area=1.659 m2.
Result: 14 panels max on 600 V (576.7 V); 35 panels for 8 kW (625 sq ft).
What Are the Published CEC Specifications for APOS Energy AP230?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for APOS Energy AP230.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 204.6 W (89.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.88 V / 7.69 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.296 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.86% (1.659 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many APOS Energy AP230 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using APOS Energy AP230 (230.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 27 | 6.21 kW | 482 sq ft | $1,554 | $2,628 |
| 8 kW Class | 35 | 8.05 kW | 625 sq ft | $2,015 | $3,407 |
| 10 kW Class | 44 | 10.12 kW | 786 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?
All closely matched APOS Energy wattages and cosmetic trims sharing the APOS Energy AP230 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| APOS Energy AP225 | 225.0 W | 200.0 W | 37.14 V | 29.48 V | 13.56% |
| APOS Energy AP230 | 230.0 W | 204.6 W | 37.32 V | 29.88 V | 13.86% |
How Many APOS Energy AP230 Modules Fit in a Cold-Weather String?
Maximum series module counts for APOS Energy AP230 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.29 V | 14 panels | 592.1 V | 23 panels |
| -10 C (14 F) | 41.19 V | 14 panels | 576.7 V | 24 panels |
| 0 C (32 F) | 40.08 V | 14 panels | 561.1 V | 24 panels |
| 25 C (77 F STC) | 37.32 V | 16 panels | 597.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP230?
Alternative CEC solar modules from competing brands near APOS Energy AP230 (230.0 W), including Guangdong Golden Glass Technologies GG230M2-30/1640x992.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Guangdong Golden Glass Technologies GG230M2-30/1640x992 Guangdong Golden Glass Technologies |
230.0 W | Tie (0 W) | 37.0 V | 14.14% | 90.3% |
| Anji Dasol Solar Energy Science & Technology DS-A4-230 Anji Dasol Solar Energy Science & Technology |
230.0 W | Tie (0 W) | 36.9 V | 13.97% | 87.3% |
| Gintung Energy ASEC-230G6M Gintung Energy |
230.0 W | Tie (0 W) | 36.87 V | 14.28% | 89.4% |
| Grape Solar GS-P-230-CS Grape Solar |
230.0 W | Tie (0 W) | 36.8 V | 14.3% | 91.7% |
What Are the Design Limits and Best-Fit Uses for APOS Energy AP230?
Evaluate APOS Energy AP230 (230.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP230 reaches 42.29 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 625 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (625 sq ft).
- 2026 tax credit baseline: cash residential installs of APOS Energy AP230 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
APOS Energy AP230 8 kW Residential Fit
Needs 35 modules (625 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Guangdong Golden Glass Technologies GG230M2-30/1640x992.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 204.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for APOS Energy AP230 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is APOS Energy AP230 PTC wattage (204.6 W) lower than STC (230.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 204.6 W PTC (89.0% retention) across APOS Energy AP230's 1.659 m2 aperture.
Who should skip APOS Energy AP230 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 APOS Energy AP230 panels (625 sq ft) leave unusable roof gaps vs. Guangdong Golden Glass Technologies GG230M2-30/1640x992.
What is the 1,000 V commercial string limit for APOS Energy AP230?
On 1,000 V commercial inverters at -10 C (41.19 V cold Voc), APOS Energy AP230 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting APOS Energy AP230.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)