Gintung Energy ASEC-230G6M is a 230.0 W STC (205.7 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.28% efficiency, 36.87 V Voc at 25 C, and 41.13 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 230.0 W
- PTC Wattage
- 205.7 W
- Voc @ 25C
- 36.87 V
- Efficiency
- 14.28%
How Does Gintung Energy ASEC-230G6M Compare Against Peer CEC Listings?
Engineering position of Gintung Energy ASEC-230G6M (230.0 W STC) vs. Anji Dasol Solar Energy Science & Technology DS-A4-230 across 1,407 CEC Multi-c-Si solar modules.
Ranking #20,522 across 21,677 CEC solar panels (below all-CEC median; higher than 4.7% of peers), Gintung Energy ASEC-230G6M operates as a compact residential or specialty off-grid module sitting 48.8 W below the 278.8 W Multi-c-Si median. Lower 36.87 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.4% PTC-to-STC thermal output (205.7 W real-world rating), 35 panels occupy 607 sq ft and offset roughly $2,015/yr at average US rates (or $3,407/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-230G6M Fall Across Listed CEC Models?
Plots Gintung Energy ASEC-230G6M at 230.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy ASEC-230G6M?
Benchmarks Gintung Energy ASEC-230G6M on STC wattage, thermal PTC/STC retention, and 14.28 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Gintung Energy ASEC-230G6M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-230G6M by Gintung Energy.
230.0 W STC · Higher Than 4.7%
230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.28% Aperture Efficiency
Power density 142.8 W/m2 (5.63 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.13 V at -10 C (575.8 V string) and 42.35 V at -20 C (14 max).
35 Panels = 8,050 W STC
Occupies 56.4 m2 (607 sq ft) producing 7,200 W PTC; NEC 690.8 OCPD floor is 12.98 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.87 * (1 + (-0.33/100) * (-10 - 25)) = 41.13 V | OCPD = 1.56 * 8.32 = 12.98 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-230G6M: Voc=36.87 V, beta_Voc=-0.33%/C, Isc=8.32 A, STC=230.0 W, Area=1.611 m2.
Result: 14 panels max on 600 V (575.8 V); 35 panels for 8 kW (607 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-230G6M?
Laboratory test ratings recorded for Gintung Energy ASEC-230G6M (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 205.7 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.3 V / 7.85 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.28% (1.611 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-230G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (607 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-230G6M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 27 | 6.21 kW | 468 sq ft | $1,554 | $2,628 |
| 8 kW Class | 35 | 8.05 kW | 607 sq ft | $2,015 | $3,407 |
| 10 kW Class | 44 | 10.12 kW | 763 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Sibling wattage bins and frame colors grouped with Gintung Energy ASEC-230G6M under Gintung Energy to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy ASEC-225G6M | 225.0 W | 201.1 W | 36.75 V | 29.19 V | 13.97% |
| Gintung Energy ASEC-230G6M | 230.0 W | 205.7 W | 36.87 V | 29.3 V | 14.28% |
| Gintung Energy ASEC-235G6M | 235.0 W | 210.3 W | 37.06 V | 29.34 V | 14.59% |
How Many Gintung Energy ASEC-230G6M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Gintung Energy ASEC-230G6M (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.35 V | 14 panels | 592.9 V | 23 panels |
| -10 C (14 F) | 41.13 V | 14 panels | 575.8 V | 24 panels |
| 0 C (32 F) | 39.91 V | 15 panels | 598.6 V | 25 panels |
| 25 C (77 F STC) | 36.87 V | 16 panels | 589.9 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-230G6M?
Closest cross-brand CEC competitors to Gintung Energy ASEC-230G6M matched near 230.0 W STC and 36.87 V Voc, led by Anji Dasol Solar Energy Science & Technology DS-A4-230.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anji Dasol Solar Energy Science & Technology DS-A4-230 Anji Dasol Solar Energy Science & Technology |
230.0 W | Tie (0 W) | 36.9 V | 13.97% | 87.3% |
| Grape Solar GS-P-230-CS Grape Solar |
230.0 W | Tie (0 W) | 36.8 V | 14.3% | 91.7% |
| Guangdong Golden Glass Technologies GG230M2-30/1640x992 Guangdong Golden Glass Technologies |
230.0 W | Tie (0 W) | 37.0 V | 14.14% | 90.3% |
| APOS Energy AP230 APOS Energy |
230.0 W | Tie (0 W) | 37.32 V | 13.86% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-230G6M?
Evaluate Gintung Energy ASEC-230G6M (230.0 W STC, 36.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-230G6M reaches 42.35 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-230G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-230G6M 8 kW Residential Fit
Needs 35 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anji Dasol Solar Energy Science & Technology DS-A4-230.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 205.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-230G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy ASEC-230G6M panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy ASEC-230G6M cold Voc rises from 36.87 V to 41.13 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (575.8 V).
How much roof area does an 8 kW array of Gintung Energy ASEC-230G6M need?
An 8 kW DC system uses 35 Gintung Energy ASEC-230G6M modules (8,050 W STC / 7,200 W PTC), covering roughly 607 sq ft and saving ~$2,015/yr at 18.54 c/kWh.
How does Gintung Energy ASEC-230G6M compare against Anji Dasol Solar Energy Science & Technology DS-A4-230?
Gintung Energy ASEC-230G6M outputs 230.0 W STC (36.87 V Voc, rank #20,522 of 21,677), while Anji Dasol Solar Energy Science & Technology DS-A4-230 delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)