Gintung Energy ASEC-135G6S is a 135.0 W STC (120.9 W PTC) Mono-c-Si solar module ranking #21,456 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.74% efficiency, 22.15 V Voc at 25 C, and 24.79 V cold Voc at -10 C (24 panels max per 600 V string).
- STC Wattage
- 135.0 W
- PTC Wattage
- 120.9 W
- Voc @ 25C
- 22.15 V
- Efficiency
- 13.74%
How Does Gintung Energy ASEC-135G6S Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-135G6S (Mono-c-Si) residential solar systems.
Homeowners evaluating Gintung Energy ASEC-135G6S need 45 panels for 6 kW or 60 panels (635 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 60 panels (635 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 24.79 V at 14 F and 25.54 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-135G6S Fall Across Listed CEC Models?
Comparison of Gintung Energy ASEC-135G6S (135.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define Gintung Energy ASEC-135G6S?
Relative ranking of Gintung Energy ASEC-135G6S across nameplate watts, 89.6% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for Gintung Energy ASEC-135G6S?
Summary of Gintung Energy ASEC-135G6S output rank, 8 kW array size (60 panels), efficiency rating, and 600 V string limit.
135.0 W STC · Higher Than 1.0%
135.0 W STC (-250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.74% Aperture Efficiency
Power density 137.3 W/m2 (6.17 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).
24 Panels Max @ -10 C (600 V)
Cold Voc reaches 24.79 V at -10 C (595.0 V string) and 25.54 V at -20 C (23 max).
60 Panels = 8,100 W STC
Occupies 59.0 m2 (635 sq ft) producing 7,254 W PTC; NEC 690.8 OCPD floor is 12.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.15 * (1 + (-0.34/100) * (-10 - 25)) = 24.79 V | OCPD = 1.56 * 8.27 = 12.9 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-135G6S: Voc=22.15 V, beta_Voc=-0.34%/C, Isc=8.27 A, STC=135.0 W, Area=0.983 m2.
Result: 24 panels max on 600 V (595.0 V); 60 panels for 8 kW (635 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-135G6S?
Complete CEC test sheet for Gintung Energy ASEC-135G6S including Isc (8.27 A), Voc (22.15 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 135.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 120.9 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 17.54 V / 7.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.74% (0.983 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-135G6S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-135G6S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 45 | 6.08 kW | 476 sq ft | $1,522 | $2,573 |
| 8 kW Class | 60 | 8.1 kW | 635 sq ft | $2,027 | $3,428 |
| 10 kW Class | 75 | 10.12 kW | 794 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Related Gintung Energy power steps and black/silver trims consolidated into this Gintung Energy ASEC-135G6S series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy ASEC-125G6S | 125.0 W | 111.7 W | 21.55 V | 17.29 V | 12.72% |
| Gintung Energy ASEC-130G6S | 130.0 W | 116.3 W | 21.96 V | 17.48 V | 13.23% |
| Gintung Energy ASEC-135G6S | 135.0 W | 120.9 W | 22.15 V | 17.54 V | 13.74% |
| Gintung Energy ASEC-140G6S | 140.0 W | 125.5 W | 22.25 V | 17.62 V | 14.24% |
How Many Gintung Energy ASEC-135G6S Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Gintung Energy ASEC-135G6S (22.15 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.54 V | 23 panels | 587.4 V | 39 panels |
| -10 C (14 F) | 24.79 V | 24 panels | 595.0 V | 40 panels |
| 0 C (32 F) | 24.03 V | 24 panels | 576.7 V | 41 panels |
| 25 C (77 F STC) | 22.15 V | 27 panels | 598.0 V | 45 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-135G6S?
Four comparable CEC modules such as United Renewable Energy Co Ltd D6P135A1F (135.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd D6P135A1F United Renewable Energy Co Ltd |
135.0 W | Tie (0 W) | 22.1 V | 13.74% | 89.3% |
| APOS Energy AP135 APOS Energy |
135.0 W | Tie (0 W) | 22.21 V | 13.2% | 88.8% |
| Centrosolar America DP36 140 Centrosolar America |
140.0 W | +5.0 W | 22.15 V | 13.85% | 88.4% |
| Solartech Energy ASC-6P-36-140 Solartech Energy |
140.0 W | +5.0 W | 22.15 V | 13.85% | 88.4% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-135G6S?
Evaluate Gintung Energy ASEC-135G6S (135.0 W STC, 22.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-135G6S reaches 25.54 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 60 panels for an 8 kW build require 635 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 60 panels (635 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-135G6S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-135G6S 8 kW Residential Fit
Needs 60 modules (635 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare United Renewable Energy Co Ltd D6P135A1F.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 120.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-135G6S by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy ASEC-135G6S PTC wattage (120.9 W) lower than STC (135.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 120.9 W PTC (89.6% retention) across Gintung Energy ASEC-135G6S's 0.983 m2 aperture.
Who should skip Gintung Energy ASEC-135G6S on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 60 Gintung Energy ASEC-135G6S panels (635 sq ft) leave unusable roof gaps vs. United Renewable Energy Co Ltd D6P135A1F.
What is the 1,000 V commercial string limit for Gintung Energy ASEC-135G6S?
On 1,000 V commercial inverters at -10 C (24.79 V cold Voc), Gintung Energy ASEC-135G6S fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-135G6S.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)