Skip to main content
WireAndSun
Calculators
CEC PV Module

Merlin Solar Technologies Inc RFP-F024W120L — CEC Solar Module Specifications

Manufacturer: Merlin Solar Technologies Inc Registry: CEC Verified Engineering Specification

Merlin Solar Technologies Inc RFP-F024W120L is a 120.0 W STC (108.7 W PTC) Mono-c-Si solar module ranking #21,493 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 15.79% efficiency, 16.3 V Voc at 25 C, and 17.79 V cold Voc at -10 C (33 panels max per 600 V string).

STC Wattage
120.0 W
PTC Wattage
108.7 W
Voc @ 25C
16.3 V
Efficiency
15.79%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Merlin Solar Technologies Inc RFP-F024W120L Compare Against Peer CEC Listings?

How Merlin Solar Technologies Inc Merlin Solar Technologies Inc RFP-F024W120L handles rooftop heat (108.7 W PTC), 8 kW sizing, and cold winter string voltage.

Merlin Solar Technologies Inc builds the Merlin Solar Technologies Inc RFP-F024W120L (Mono-c-Si) as a compact residential or specialty off-grid module delivering 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). Compared against SunTegra STS-114M-B4U (114.0 W), this model holds typical 90.6% PTC-to-STC thermal output (108.7 W real-world rating). Lower 16.3 V string voltage fits 33 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.35 A overcurrent floor served by a 15 A breaker.

Where Does Merlin Solar Technologies Inc RFP-F024W120L Fall Across Listed CEC Models?

Where Merlin Solar Technologies Inc RFP-F024W120L (120.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Merlin Solar Technologies Inc RFP-F024W120L (120.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMerlin Solar Techn: 120.0 W

What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F024W120L?

Percentile placement of Merlin Solar Technologies Inc RFP-F024W120L across power density (157.9 W/m2), thermal retention, and nameplate STC wattage.

Merlin Solar Technologies Inc RFP-F024W120L Engineering BenchmarksPercentile comparison of Merlin Solar Technologies Inc RFP-F024W120L wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage120.0 WPTC/STC Retention90.6%Module Efficiency15.79%

What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F024W120L?

Four critical engineering numbers homeowners and solar installers check first when reviewing Merlin Solar Technologies Inc RFP-F024W120L specifications.

Rank #21,493 / 21,677

120.0 W STC · Higher Than 0.8%

120.0 W STC (-265.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,445

15.79% Aperture Efficiency

Power density 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

33 Panels Max @ -10 C (600 V)

Cold Voc reaches 17.79 V at -10 C (587.1 V string) and 18.22 V at -20 C (32 max).

8 kW Reference Array

67 Panels = 8,040 W STC

Occupies 50.9 m2 (548 sq ft) producing 7,283 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 16.3 * (1 + (-0.262/100) * (-10 - 25)) = 17.79 V | OCPD = 1.56 * 9.2 = 14.35 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F024W120L: Voc=16.3 V, beta_Voc=-0.262%/C, Isc=9.2 A, STC=120.0 W, Area=0.76 m2.

Result: 33 panels max on 600 V (587.1 V); 67 panels for 8 kW (548 sq ft).

What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F024W120L?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Merlin Solar Technologies Inc RFP-F024W120L.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc RFP-F024W120L.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 120.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 108.7 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 16.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 13.69 V / 8.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.79% (0.76 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many Merlin Solar Technologies Inc RFP-F024W120L Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Merlin Solar Technologies Inc RFP-F024W120L (120.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 50 6.0 kW 409 sq ft $1,502 $2,539
8 kW Class 67 8.04 kW 548 sq ft $2,012 $3,403
10 kW Class 84 10.08 kW 687 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

All closely matched Merlin Solar Technologies Inc wattages and cosmetic trims sharing the Merlin Solar Technologies Inc RFP-F024W120L architecture.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc RFP-F024W120L wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Merlin Solar Technologies Inc RFP-F024W117L 117.0 W 105.9 W 16.25 V 13.49 V 15.39%
Merlin Solar Technologies Inc RFP-F024W120L 120.0 W 108.7 W 16.3 V 13.69 V 15.79%
Merlin Solar Technologies Inc RFP-F024W123L 123.0 W 111.5 W 16.35 V 13.89 V 16.18%

How Many Merlin Solar Technologies Inc RFP-F024W120L Modules Fit in a Cold-Weather String?

Maximum series module counts for Merlin Solar Technologies Inc RFP-F024W120L from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=16.3V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 18.22 V 32 panels 583.0 V 54 panels
-10 C (14 F) 17.79 V 33 panels 587.1 V 56 panels
0 C (32 F) 17.37 V 34 panels 590.6 V 57 panels
25 C (77 F STC) 16.3 V 36 panels 586.8 V 61 panels

Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F024W120L?

Alternative CEC solar modules from competing brands near Merlin Solar Technologies Inc RFP-F024W120L (120.0 W), including SunTegra STS-114M-B4U.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
SunTegra STS-114M-B4U
SunTegra
114.0 W -6.0 W 15.52 V 17.27% 86.8%
SunStyle M110 870
SunStyle
110.0 W -10.0 W 16.1 V 14.47% 89.3%
Solar Frame Solutions Inc SFS135T
Solar Frame Solutions Inc
135.0 W +15.0 W 16.4 V 16.46% 92.1%
WAAREE ENERGIES LIMITED WU-120
WAAREE ENERGIES LIMITED
120.0 W Tie (0 W) 21.0 V 12.2% 88.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F024W120L?

Evaluate Merlin Solar Technologies Inc RFP-F024W120L (120.0 W STC, 16.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F024W120L reaches 18.22 V per panel—exceeding 32 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 67 panels for an 8 kW build require 548 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (548 sq ft).
  • 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F024W120L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Merlin Solar Technologies Inc RFP-F024W120L 8 kW Residential Fit

Needs 67 modules (548 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 33 panels (-10 C) or 32 panels (-20 C), or compare SunTegra STS-114M-B4U.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 108.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc RFP-F024W120L by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Merlin Solar Technologies Inc RFP-F024W120L?

Multiplying Merlin Solar Technologies Inc RFP-F024W120L's 9.2 A short-circuit current by 1.56 equals 14.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Merlin Solar Technologies Inc RFP-F024W120L pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 17.79 V cold Voc at 14 F and handles 9.2 A Isc; string inverters cap Merlin Solar Technologies Inc RFP-F024W120L at 33 panels on 600 V.

Is Merlin Solar Technologies Inc RFP-F024W120L eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Merlin Solar Technologies Inc RFP-F024W120L rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.