Merlin Solar Technologies Inc RFP-F024W120L is a 120.0 W STC (108.7 W PTC) Mono-c-Si solar module ranking #21,493 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 15.79% efficiency, 16.3 V Voc at 25 C, and 17.79 V cold Voc at -10 C (33 panels max per 600 V string).
- STC Wattage
- 120.0 W
- PTC Wattage
- 108.7 W
- Voc @ 25C
- 16.3 V
- Efficiency
- 15.79%
How Does Merlin Solar Technologies Inc RFP-F024W120L Compare Against Peer CEC Listings?
How Merlin Solar Technologies Inc Merlin Solar Technologies Inc RFP-F024W120L handles rooftop heat (108.7 W PTC), 8 kW sizing, and cold winter string voltage.
Merlin Solar Technologies Inc builds the Merlin Solar Technologies Inc RFP-F024W120L (Mono-c-Si) as a compact residential or specialty off-grid module delivering 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). Compared against SunTegra STS-114M-B4U (114.0 W), this model holds typical 90.6% PTC-to-STC thermal output (108.7 W real-world rating). Lower 16.3 V string voltage fits 33 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.35 A overcurrent floor served by a 15 A breaker.
Where Does Merlin Solar Technologies Inc RFP-F024W120L Fall Across Listed CEC Models?
Where Merlin Solar Technologies Inc RFP-F024W120L (120.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F024W120L?
Percentile placement of Merlin Solar Technologies Inc RFP-F024W120L across power density (157.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F024W120L?
Four critical engineering numbers homeowners and solar installers check first when reviewing Merlin Solar Technologies Inc RFP-F024W120L specifications.
120.0 W STC · Higher Than 0.8%
120.0 W STC (-265.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.79% Aperture Efficiency
Power density 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
33 Panels Max @ -10 C (600 V)
Cold Voc reaches 17.79 V at -10 C (587.1 V string) and 18.22 V at -20 C (32 max).
67 Panels = 8,040 W STC
Occupies 50.9 m2 (548 sq ft) producing 7,283 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 16.3 * (1 + (-0.262/100) * (-10 - 25)) = 17.79 V | OCPD = 1.56 * 9.2 = 14.35 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F024W120L: Voc=16.3 V, beta_Voc=-0.262%/C, Isc=9.2 A, STC=120.0 W, Area=0.76 m2.
Result: 33 panels max on 600 V (587.1 V); 67 panels for 8 kW (548 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F024W120L?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Merlin Solar Technologies Inc RFP-F024W120L.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 120.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 108.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 16.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 13.69 V / 8.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.79% (0.76 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc RFP-F024W120L Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Merlin Solar Technologies Inc RFP-F024W120L (120.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 50 | 6.0 kW | 409 sq ft | $1,502 | $2,539 |
| 8 kW Class | 67 | 8.04 kW | 548 sq ft | $2,012 | $3,403 |
| 10 kW Class | 84 | 10.08 kW | 687 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?
All closely matched Merlin Solar Technologies Inc wattages and cosmetic trims sharing the Merlin Solar Technologies Inc RFP-F024W120L architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc RFP-F024W117L | 117.0 W | 105.9 W | 16.25 V | 13.49 V | 15.39% |
| Merlin Solar Technologies Inc RFP-F024W120L | 120.0 W | 108.7 W | 16.3 V | 13.69 V | 15.79% |
| Merlin Solar Technologies Inc RFP-F024W123L | 123.0 W | 111.5 W | 16.35 V | 13.89 V | 16.18% |
How Many Merlin Solar Technologies Inc RFP-F024W120L Modules Fit in a Cold-Weather String?
Maximum series module counts for Merlin Solar Technologies Inc RFP-F024W120L from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 18.22 V | 32 panels | 583.0 V | 54 panels |
| -10 C (14 F) | 17.79 V | 33 panels | 587.1 V | 56 panels |
| 0 C (32 F) | 17.37 V | 34 panels | 590.6 V | 57 panels |
| 25 C (77 F STC) | 16.3 V | 36 panels | 586.8 V | 61 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F024W120L?
Alternative CEC solar modules from competing brands near Merlin Solar Technologies Inc RFP-F024W120L (120.0 W), including SunTegra STS-114M-B4U.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| SunTegra STS-114M-B4U SunTegra |
114.0 W | -6.0 W | 15.52 V | 17.27% | 86.8% |
| SunStyle M110 870 SunStyle |
110.0 W | -10.0 W | 16.1 V | 14.47% | 89.3% |
| Solar Frame Solutions Inc SFS135T Solar Frame Solutions Inc |
135.0 W | +15.0 W | 16.4 V | 16.46% | 92.1% |
| WAAREE ENERGIES LIMITED WU-120 WAAREE ENERGIES LIMITED |
120.0 W | Tie (0 W) | 21.0 V | 12.2% | 88.7% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F024W120L?
Evaluate Merlin Solar Technologies Inc RFP-F024W120L (120.0 W STC, 16.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F024W120L reaches 18.22 V per panel—exceeding 32 panels in series voids 600 V inverter warranties.
- Footprint constraint: 67 panels for an 8 kW build require 548 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (548 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F024W120L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc RFP-F024W120L 8 kW Residential Fit
Needs 67 modules (548 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 33 panels (-10 C) or 32 panels (-20 C), or compare SunTegra STS-114M-B4U.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 108.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc RFP-F024W120L by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Merlin Solar Technologies Inc RFP-F024W120L?
Multiplying Merlin Solar Technologies Inc RFP-F024W120L's 9.2 A short-circuit current by 1.56 equals 14.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Merlin Solar Technologies Inc RFP-F024W120L pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 17.79 V cold Voc at 14 F and handles 9.2 A Isc; string inverters cap Merlin Solar Technologies Inc RFP-F024W120L at 33 panels on 600 V.
Is Merlin Solar Technologies Inc RFP-F024W120L eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Merlin Solar Technologies Inc RFP-F024W120L rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)