SunStyle M110 870 is a 110.0 W STC (98.2 W PTC) Mono-c-Si solar module ranking #21,527 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 14.47% efficiency, 16.1 V Voc at 25 C, and 17.68 V cold Voc at -10 C (33 panels max per 600 V string).
- STC Wattage
- 110.0 W
- PTC Wattage
- 98.2 W
- Voc @ 25C
- 16.1 V
- Efficiency
- 14.47%
How Does SunStyle M110 870 Compare Against Peer CEC Listings?
Solar engineering breakdown for SunStyle M110 870: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Across 5,889 Mono-c-Si listings from SunStyle and peers, SunStyle M110 870 stands 300.0 W below the 410.0 W Mono-c-Si median and typical 89.3% PTC-to-STC thermal output (98.2 W real-world rating). Sizing 6 kW (55 panels) to 10 kW (91 panels) yields $1,514-$2,505/yr in baseline US bill offset. Lower 16.1 V string voltage fits 33 panels in series at 14 F and pairs easily with microinverters.
Where Does SunStyle M110 870 Fall Across Listed CEC Models?
Distribution marker showing SunStyle M110 870 (110.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define SunStyle M110 870?
Dataset percentiles tracking SunStyle M110 870 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for SunStyle M110 870?
Benchmark highlights for SunStyle M110 870 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
110.0 W STC · Higher Than 0.7%
110.0 W STC (-275.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.47% Aperture Efficiency
Power density 144.7 W/m2 (5.44 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).
33 Panels Max @ -10 C (600 V)
Cold Voc reaches 17.68 V at -10 C (583.4 V string) and 18.14 V at -20 C (33 max).
73 Panels = 8,030 W STC
Occupies 55.5 m2 (597 sq ft) producing 7,169 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 16.1 * (1 + (-0.281/100) * (-10 - 25)) = 17.68 V | OCPD = 1.56 * 9.2 = 14.35 A
Inputs from CEC Modules.csv for SunStyle M110 870: Voc=16.1 V, beta_Voc=-0.281%/C, Isc=9.2 A, STC=110.0 W, Area=0.76 m2.
Result: 33 panels max on 600 V (583.4 V); 73 panels for 8 kW (597 sq ft).
What Are the Published CEC Specifications for SunStyle M110 870?
Official CEC datasheet figures for SunStyle M110 870 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 110.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 98.2 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 16.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 13.1 V / 8.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.47% (0.76 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunStyle M110 870 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many SunStyle M110 870 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 55 | 6.05 kW | 450 sq ft | $1,514 | $2,561 |
| 8 kW Class | 73 | 8.03 kW | 597 sq ft | $2,010 | $3,398 |
| 10 kW Class | 91 | 10.01 kW | 744 sq ft | $2,505 | $4,236 |
How Many SunStyle M110 870 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on SunStyle M110 870 (17.68 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 18.14 V | 33 panels | 598.6 V | 55 panels |
| -10 C (14 F) | 17.68 V | 33 panels | 583.4 V | 56 panels |
| 0 C (32 F) | 17.23 V | 34 panels | 585.8 V | 58 panels |
| 25 C (77 F STC) | 16.1 V | 37 panels | 595.7 V | 62 panels |
Which Cross-Brand Solar Modules Compare Closest to SunStyle M110 870?
Competing CEC solar panels closest to SunStyle M110 870 in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc FX110.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FX110 Merlin Solar Technologies Inc |
110.0 W | Tie (0 W) | 15.6 V | 14.53% | 91.5% |
| SunTegra STS-114M-B4U SunTegra |
114.0 W | +4.0 W | 15.52 V | 17.27% | 86.8% |
| Merlin Solar Technologies Inc FXS 105-W Merlin Solar Technologies Inc |
105.0 W | -5.0 W | 15.5 V | 14.0% | 91.6% |
| Merlin Solar Technologies Inc RFP-F024B117L Merlin Solar Technologies Inc |
117.0 W | +7.0 W | 16.3 V | 15.39% | 89.5% |
What Are the Design Limits and Best-Fit Uses for SunStyle M110 870?
Evaluate SunStyle M110 870 (110.0 W STC, 16.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunStyle M110 870 reaches 18.14 V per panel—exceeding 33 panels in series voids 600 V inverter warranties.
- Footprint constraint: 73 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (597 sq ft).
- 2026 tax credit baseline: cash residential installs of SunStyle M110 870 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunStyle M110 870 8 kW Residential Fit
Needs 73 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 33 panels (-10 C) or 33 panels (-20 C), or compare Merlin Solar Technologies Inc FX110.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 98.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunStyle M110 870 by SunStyle grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SunStyle M110 870?
Multiplying SunStyle M110 870's 9.2 A short-circuit current by 1.56 equals 14.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can SunStyle M110 870 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 17.68 V cold Voc at 14 F and handles 9.2 A Isc; string inverters cap SunStyle M110 870 at 33 panels on 600 V.
Is SunStyle M110 870 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunStyle M110 870 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)