Merlin Solar Technologies Inc FX110 is a 110.0 W STC (100.7 W PTC) Mono-c-Si solar module ranking #21,527 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 14.53% efficiency, 15.6 V Voc at 25 C, and 17.29 V cold Voc at -10 C (34 panels max per 600 V string).
- STC Wattage
- 110.0 W
- PTC Wattage
- 100.7 W
- Voc @ 25C
- 15.6 V
- Efficiency
- 14.53%
How Does Merlin Solar Technologies Inc FX110 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Merlin Solar Technologies Inc FX110 (Mono-c-Si) residential solar systems.
Homeowners evaluating Merlin Solar Technologies Inc FX110 need 55 panels for 6 kW or 73 panels (595 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (595 sq ft). Under NEC 690.7(A), beta_Voc (-0.31%/C) pushes open-circuit voltage to 17.29 V at 14 F and 17.78 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Merlin Solar Technologies Inc FX110 Fall Across Listed CEC Models?
Comparison of Merlin Solar Technologies Inc FX110 (110.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Merlin Solar Technologies Inc FX110?
Relative ranking of Merlin Solar Technologies Inc FX110 across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc FX110?
Summary of Merlin Solar Technologies Inc FX110 output rank, 8 kW array size (73 panels), efficiency rating, and 600 V string limit.
110.0 W STC · Higher Than 0.7%
110.0 W STC (-275.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.53% Aperture Efficiency
Power density 145.3 W/m2 (5.38 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).
34 Panels Max @ -10 C (600 V)
Cold Voc reaches 17.29 V at -10 C (587.9 V string) and 17.78 V at -20 C (33 max).
73 Panels = 8,030 W STC
Occupies 55.3 m2 (595 sq ft) producing 7,351 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 15.6 * (1 + (-0.31/100) * (-10 - 25)) = 17.29 V | OCPD = 1.56 * 8.98 = 14.01 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc FX110: Voc=15.6 V, beta_Voc=-0.31%/C, Isc=8.98 A, STC=110.0 W, Area=0.757 m2.
Result: 34 panels max on 600 V (587.9 V); 73 panels for 8 kW (595 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc FX110?
Complete CEC test sheet for Merlin Solar Technologies Inc FX110 including Isc (8.98 A), Voc (15.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 110.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 100.7 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 15.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 12.7 V / 8.65 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.53% (0.757 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc FX110 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Merlin Solar Technologies Inc FX110.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 55 | 6.05 kW | 448 sq ft | $1,514 | $2,561 |
| 8 kW Class | 73 | 8.03 kW | 595 sq ft | $2,010 | $3,398 |
| 10 kW Class | 91 | 10.01 kW | 741 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?
Related Merlin Solar Technologies Inc power steps and black/silver trims consolidated into this Merlin Solar Technologies Inc FX110 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FX105 | 105.0 W | 96.0 W | 15.4 V | 12.5 V | 13.87% |
| Merlin Solar Technologies Inc FX110 | 110.0 W | 100.7 W | 15.6 V | 12.7 V | 14.53% |
How Many Merlin Solar Technologies Inc FX110 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Merlin Solar Technologies Inc FX110 (15.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 17.78 V | 33 panels | 586.7 V | 56 panels |
| -10 C (14 F) | 17.29 V | 34 panels | 587.9 V | 57 panels |
| 0 C (32 F) | 16.81 V | 35 panels | 588.3 V | 59 panels |
| 25 C (77 F STC) | 15.6 V | 38 panels | 592.8 V | 64 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc FX110?
Four comparable CEC modules such as SunStyle M110 870 (110.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| SunStyle M110 870 SunStyle |
110.0 W | Tie (0 W) | 16.1 V | 14.47% | 89.3% |
| SunTegra STS-114M-B4U SunTegra |
114.0 W | +4.0 W | 15.52 V | 17.27% | 86.8% |
| Heliene 20M-100GH Heliene |
100.0 W | -10.0 W | 13.3 V | 6.17% | 85.2% |
| Solar Frame Solutions Inc SFS135T Solar Frame Solutions Inc |
135.0 W | +25.0 W | 16.4 V | 16.46% | 92.1% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc FX110?
Evaluate Merlin Solar Technologies Inc FX110 (110.0 W STC, 15.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc FX110 reaches 17.78 V per panel—exceeding 33 panels in series voids 600 V inverter warranties.
- Footprint constraint: 73 panels for an 8 kW build require 595 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (595 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc FX110 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc FX110 8 kW Residential Fit
Needs 73 modules (595 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 34 panels (-10 C) or 33 panels (-20 C), or compare SunStyle M110 870.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 100.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc FX110 by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Merlin Solar Technologies Inc FX110 PTC wattage (100.7 W) lower than STC (110.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 100.7 W PTC (91.5% retention) across Merlin Solar Technologies Inc FX110's 0.757 m2 aperture.
Who should skip Merlin Solar Technologies Inc FX110 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 73 Merlin Solar Technologies Inc FX110 panels (595 sq ft) leave unusable roof gaps vs. SunStyle M110 870.
What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc FX110?
On 1,000 V commercial inverters at -10 C (17.29 V cold Voc), Merlin Solar Technologies Inc FX110 fits up to 57 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)