Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 108HC-405 M10 SL — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 108HC-405 M10 SL is a 405.0 W STC (381.5 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.54% efficiency, 37.74 V Voc at 25 C, and 41.07 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
381.5 W
Voc @ 25C
37.74 V
Efficiency
21.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 108HC-405 M10 SL Compare Against Peer CEC Listings?

Engineering position of Heliene 108HC-405 M10 SL (405.0 W STC) vs. Alexus Solar ALEX-405-B-54-S across 5,889 CEC Mono-c-Si solar modules.

Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), Heliene 108HC-405 M10 SL operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Lower 37.74 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), 20 panels occupy 405 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Heliene 108HC-405 M10 SL Fall Across Listed CEC Models?

Plots Heliene 108HC-405 M10 SL at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 108HC-405 M10 SL (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 108HC-405 : 405.0 W

What Dataset Percentiles Define Heliene 108HC-405 M10 SL?

Benchmarks Heliene 108HC-405 M10 SL on STC wattage, thermal PTC/STC retention, and 21.54 aperture conversion efficiency against CEC peers.

Heliene 108HC-405 M10 SL Engineering BenchmarksPercentile comparison of Heliene 108HC-405 M10 SL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention94.2%Module Efficiency21.54%

What Do the Dataset Ranks Show for Heliene 108HC-405 M10 SL?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 108HC-405 M10 SL by Heliene.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,253

21.54% Aperture Efficiency

Power density 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.07 V at -10 C (575.0 V string) and 42.02 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,630 W PTC; NEC 690.8 OCPD floor is 20.78 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.74 * (1 + (-0.252/100) * (-10 - 25)) = 41.07 V | OCPD = 1.56 * 13.32 = 20.78 A

Inputs from CEC Modules.csv for Heliene 108HC-405 M10 SL: Voc=37.74 V, beta_Voc=-0.252%/C, Isc=13.32 A, STC=405.0 W, Area=1.88 m2.

Result: 14 panels max on 600 V (575.0 V); 20 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for Heliene 108HC-405 M10 SL?

Laboratory test ratings recorded for Heliene 108HC-405 M10 SL (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 108HC-405 M10 SL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.5 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.15 V / 12.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.252 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.54% (1.88 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 108HC-405 M10 SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 108HC-405 M10 SL.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 304 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 405 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 506 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Sibling wattage bins and frame colors grouped with Heliene 108HC-405 M10 SL under Heliene to prevent duplicate spec pages.

Sibling CEC listings grouped into the Heliene 108HC-405 M10 SL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 108HC-400 M10 SL 400.0 W 376.7 W 37.56 V 31.81 V 21.28%
Heliene 108HC-405 M10 SL 405.0 W 381.5 W 37.74 V 32.15 V 21.54%
Heliene 108HC-410 M10 SL 410.0 W 386.3 W 38.03 V 32.49 V 21.81%

How Many Heliene 108HC-405 M10 SL Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 108HC-405 M10 SL (beta_Voc -0.252%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.74V and beta_Voc=-0.252%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.02 V 14 panels 588.3 V 23 panels
-10 C (14 F) 41.07 V 14 panels 575.0 V 24 panels
0 C (32 F) 40.12 V 14 panels 561.7 V 24 panels
25 C (77 F STC) 37.74 V 15 panels 566.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 108HC-405 M10 SL?

Closest cross-brand CEC competitors to Heliene 108HC-405 M10 SL matched near 405.0 W STC and 37.74 V Voc, led by Alexus Solar ALEX-405-B-54-S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
CertainTeed CTM10405HC11-06
CertainTeed
405.0 W Tie (0 W) 37.23 V 20.77% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 108HC-405 M10 SL?

Evaluate Heliene 108HC-405 M10 SL (405.0 W STC, 37.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 108HC-405 M10 SL reaches 42.02 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (405 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 108HC-405 M10 SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 108HC-405 M10 SL 8 kW Residential Fit

Needs 20 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alexus Solar ALEX-405-B-54-S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 108HC-405 M10 SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

How many Heliene 108HC-405 M10 SL panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 108HC-405 M10 SL cold Voc rises from 37.74 V to 41.07 V (beta_Voc -0.252%/C), capping a 600 V string at 14 panels (575.0 V).

How much roof area does an 8 kW array of Heliene 108HC-405 M10 SL need?

An 8 kW DC system uses 20 Heliene 108HC-405 M10 SL modules (8,100 W STC / 7,630 W PTC), covering roughly 405 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Heliene 108HC-405 M10 SL compare against Alexus Solar ALEX-405-B-54-S?

Heliene 108HC-405 M10 SL outputs 405.0 W STC (37.74 V Voc, rank #8,961 of 21,677), while Alexus Solar ALEX-405-B-54-S delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.