Skip to main content
WireAndSun
Calculators
CEC PV Module

Alexus Solar ALEX-405-B-54-S — CEC Solar Module Specifications

Manufacturer: Alexus Solar Registry: CEC Verified Engineering Specification

Alexus Solar ALEX-405-B-54-S is a 405.0 W STC (374.7 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 37.38 V Voc at 25 C, and 41.44 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
374.7 W
Voc @ 25C
37.38 V
Efficiency
20.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Alexus Solar ALEX-405-B-54-S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Alexus Solar ALEX-405-B-54-S (Mono-c-Si) residential solar systems.

Homeowners evaluating Alexus Solar ALEX-405-B-54-S need 15 panels for 6 kW or 20 panels (420 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.31%/C) pushes open-circuit voltage to 41.44 V at 14 F and 42.59 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Alexus Solar ALEX-405-B-54-S Fall Across Listed CEC Models?

Comparison of Alexus Solar ALEX-405-B-54-S (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Alexus Solar ALEX-405-B-54-S (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAlexus Solar ALEX-: 405.0 W

What Dataset Percentiles Define Alexus Solar ALEX-405-B-54-S?

Relative ranking of Alexus Solar ALEX-405-B-54-S across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Alexus Solar ALEX-405-B-54-S Engineering BenchmarksPercentile comparison of Alexus Solar ALEX-405-B-54-S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.5%Module Efficiency20.77%

What Do the Dataset Ranks Show for Alexus Solar ALEX-405-B-54-S?

Summary of Alexus Solar ALEX-405-B-54-S output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.44 V at -10 C (580.2 V string) and 42.59 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,494 W PTC; NEC 690.8 OCPD floor is 21.47 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.38 * (1 + (-0.31/100) * (-10 - 25)) = 41.44 V | OCPD = 1.56 * 13.76 = 21.47 A

Inputs from CEC Modules.csv for Alexus Solar ALEX-405-B-54-S: Voc=37.38 V, beta_Voc=-0.31%/C, Isc=13.76 A, STC=405.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (580.2 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Alexus Solar ALEX-405-B-54-S?

Complete CEC test sheet for Alexus Solar ALEX-405-B-54-S including Isc (13.76 A), Voc (37.38 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Alexus Solar ALEX-405-B-54-S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 374.7 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.35 V / 12.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.77% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Alexus Solar ALEX-405-B-54-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Alexus Solar ALEX-405-B-54-S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 315 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 420 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 525 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Alexus Solar Series?

Related Alexus Solar power steps and black/silver trims consolidated into this Alexus Solar ALEX-405-B-54-S series guide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Alexus Solar ALEX-405-B-54-S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Alexus Solar ALEX-400-B-54-S 400.0 W 370.0 W 37.21 V 31.18 V 20.51%
Alexus Solar ALEX-405-B-54-S 405.0 W 374.7 W 37.38 V 31.35 V 20.77%
Alexus Solar ALEX-410-B-54-S 410.0 W 379.5 W 37.55 V 31.52 V 21.03%

How Many Alexus Solar ALEX-405-B-54-S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Alexus Solar ALEX-405-B-54-S (37.38 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.38V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.59 V 14 panels 596.3 V 23 panels
-10 C (14 F) 41.44 V 14 panels 580.2 V 24 panels
0 C (32 F) 40.28 V 14 panels 563.9 V 24 panels
25 C (77 F STC) 37.38 V 16 panels 598.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Alexus Solar ALEX-405-B-54-S?

Four comparable CEC modules such as Convalt Manufacturing LLC CVLT405-108M-BB (405.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
CertainTeed CTM10405HC11-06
CertainTeed
405.0 W Tie (0 W) 37.23 V 20.77% 93.8%
Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
405.0 W Tie (0 W) 37.2 V 20.77% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Alexus Solar ALEX-405-B-54-S?

Evaluate Alexus Solar ALEX-405-B-54-S (405.0 W STC, 37.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Alexus Solar ALEX-405-B-54-S reaches 42.59 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Alexus Solar ALEX-405-B-54-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Alexus Solar ALEX-405-B-54-S 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Convalt Manufacturing LLC CVLT405-108M-BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Alexus Solar ALEX-405-B-54-S by Alexus Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Alexus Solar ALEX-405-B-54-S PTC wattage (374.7 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 374.7 W PTC (92.5% retention) across Alexus Solar ALEX-405-B-54-S's 1.95 m2 aperture.

Who should skip Alexus Solar ALEX-405-B-54-S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Alexus Solar ALEX-405-B-54-S panels (420 sq ft) leave unusable roof gaps vs. Convalt Manufacturing LLC CVLT405-108M-BB.

What is the 1,000 V commercial string limit for Alexus Solar ALEX-405-B-54-S?

On 1,000 V commercial inverters at -10 C (41.44 V cold Voc), Alexus Solar ALEX-405-B-54-S fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Alexus Solar ALEX-405-B-54-S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.