Alexus Solar ALEX-550-B-72-S — CEC Solar Module Specifications

Manufacturer: Alexus Solar Registry: CEC Verified Engineering Specification

Alexus Solar ALEX-550-B-72-S is a 550.0 W STC (509.3 W PTC) Multi-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.32% efficiency, 49.84 V Voc at 25 C, and 55.25 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
509.3 W
Voc @ 25C
49.84 V
Efficiency
21.32%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Alexus Solar ALEX-550-B-72-S Compare Against Peer CEC Listings?

Solar engineering breakdown for Alexus Solar ALEX-550-B-72-S: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Measured at 550.0 W STC and 509.3 W PTC, Alexus Solar ALEX-550-B-72-S sits +165.0 W vs all-CEC median (top 13.8%; higher than 86.2% of peers) among 21,677 listed modules. Power density reaches 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). Higher 49.84 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144 rates 550.0 W.

Where Does Alexus Solar ALEX-550-B-72-S Fall Across Listed CEC Models?

Distribution marker showing Alexus Solar ALEX-550-B-72-S (550.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Alexus Solar ALEX-550-B-72-S (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAlexus Solar ALEX-: 550.0 W

What Dataset Percentiles Define Alexus Solar ALEX-550-B-72-S?

Dataset percentiles tracking Alexus Solar ALEX-550-B-72-S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Alexus Solar ALEX-550-B-72-S Engineering BenchmarksPercentile comparison of Alexus Solar ALEX-550-B-72-S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention92.6%Module Efficiency21.32%

What Do the Dataset Ranks Show for Alexus Solar ALEX-550-B-72-S?

Benchmark highlights for Alexus Solar ALEX-550-B-72-S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #4,973

21.32% Aperture Efficiency

Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.25 V at -10 C (552.5 V string) and 56.79 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,640 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.84 * (1 + (-0.31/100) * (-10 - 25)) = 55.25 V | OCPD = 1.56 * 13.98 = 21.81 A

Inputs from CEC Modules.csv for Alexus Solar ALEX-550-B-72-S: Voc=49.84 V, beta_Voc=-0.31%/C, Isc=13.98 A, STC=550.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (552.5 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Alexus Solar ALEX-550-B-72-S?

Official CEC datasheet figures for Alexus Solar ALEX-550-B-72-S (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Alexus Solar ALEX-550-B-72-S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 509.3 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.84 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.99 V / 13.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.32% (2.58 m2) Array roof footprint density
Cell Count & Technology 24 cells (Multi-c-Si) Monofacial backsheet

How Many Alexus Solar ALEX-550-B-72-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Alexus Solar ALEX-550-B-72-S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 305 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 417 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 528 sq ft $2,616 $4,423

How Many Alexus Solar ALEX-550-B-72-S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Alexus Solar ALEX-550-B-72-S (55.25 V at 14 F).

Computed from Voc=49.84V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.79 V 10 panels 567.9 V 17 panels
-10 C (14 F) 55.25 V 10 panels 552.5 V 18 panels
0 C (32 F) 53.7 V 11 panels 590.7 V 18 panels
25 C (77 F STC) 49.84 V 12 panels 598.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Alexus Solar ALEX-550-B-72-S?

Competing CEC solar panels closest to Alexus Solar ALEX-550-B-72-S in nameplate wattage and Voc, starting with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
550.0 W Tie (0 W) 49.8 V 21.48% 93.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
550.0 W Tie (0 W) 49.8 V 21.48% 93.5%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW550M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
550.0 W Tie (0 W) 49.9 V 28.95% 95.3%
Exiom Solution S A EX545-144MH
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.65% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Alexus Solar ALEX-550-B-72-S?

Evaluate Alexus Solar ALEX-550-B-72-S (550.0 W STC, 49.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Alexus Solar ALEX-550-B-72-S reaches 56.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Alexus Solar ALEX-550-B-72-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Alexus Solar ALEX-550-B-72-S 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 509.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Alexus Solar ALEX-550-B-72-S by Alexus Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Alexus Solar ALEX-550-B-72-S panels fit on a 600 V winter solar string?

At -10 C (14 F), Alexus Solar ALEX-550-B-72-S cold Voc rises from 49.84 V to 55.25 V (beta_Voc -0.31%/C), capping a 600 V string at 10 panels (552.5 V).

How much roof area does an 8 kW array of Alexus Solar ALEX-550-B-72-S need?

An 8 kW DC system uses 15 Alexus Solar ALEX-550-B-72-S modules (8,250 W STC / 7,640 W PTC), covering roughly 417 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does Alexus Solar ALEX-550-B-72-S compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144?

Alexus Solar ALEX-550-B-72-S outputs 550.0 W STC (49.84 V Voc, rank #2,737 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144 delivers 550.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.