Manufacturer: Alexus Solar Registry: CEC Verified Engineering Specification

Alexus Solar ALEX-545-B-72-S is a 545.0 W STC (504.5 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.12% efficiency, 49.68 V Voc at 25 C, and 55.07 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
545.0 W
PTC Wattage
504.5 W
Voc @ 25C
49.68 V
Efficiency
21.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Alexus Solar ALEX-545-B-72-S Compare Against Peer CEC Listings?

Solar engineering breakdown for Alexus Solar ALEX-545-B-72-S: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Across 5,889 Mono-c-Si listings from Alexus Solar and peers, Alexus Solar ALEX-545-B-72-S stands 135.0 W above the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,637-$2,593/yr in baseline US bill offset. Higher 49.68 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Alexus Solar ALEX-545-B-72-S Fall Across Listed CEC Models?

Distribution marker showing Alexus Solar ALEX-545-B-72-S (545.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Alexus Solar ALEX-545-B-72-S (545.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAlexus Solar ALEX-: 545.0 W

What Dataset Percentiles Define Alexus Solar ALEX-545-B-72-S?

Dataset percentiles tracking Alexus Solar ALEX-545-B-72-S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Alexus Solar ALEX-545-B-72-S Engineering BenchmarksPercentile comparison of Alexus Solar ALEX-545-B-72-S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage545.0 WPTC/STC Retention92.6%Module Efficiency21.12%

What Do the Dataset Ranks Show for Alexus Solar ALEX-545-B-72-S?

Benchmark highlights for Alexus Solar ALEX-545-B-72-S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #2,998 / 21,677

Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.07 V at -10 C (550.7 V string) and 56.61 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,175 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,568 W PTC; NEC 690.8 OCPD floor is 21.7 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.68 * (1 + (-0.31/100) * (-10 - 25)) = 55.07 V | OCPD = 1.56 * 13.91 = 21.7 A

Inputs from CEC Modules.csv for Alexus Solar ALEX-545-B-72-S: Voc=49.68 V, beta_Voc=-0.31%/C, Isc=13.91 A, STC=545.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (550.7 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Alexus Solar ALEX-545-B-72-S?

Official CEC datasheet figures for Alexus Solar ALEX-545-B-72-S (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Alexus Solar ALEX-545-B-72-S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 545.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 504.5 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.83 V / 13.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.12% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Alexus Solar ALEX-545-B-72-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Alexus Solar ALEX-545-B-72-S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.54 kW 333 sq ft $1,637 $2,768
8 kW Class 15 8.18 kW 417 sq ft $2,047 $3,462
10 kW Class 19 10.36 kW 528 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This Alexus Solar Series?

Consolidated Alexus Solar wattage variants sharing the Alexus Solar ALEX-545-B-72-S mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Alexus Solar ALEX-545-B-72-S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Alexus Solar ALEX-540-B-72-S 540.0 W 499.7 W 49.52 V 41.67 V 20.93%
Alexus Solar ALEX-545-B-72-S 545.0 W 504.5 W 49.68 V 41.83 V 21.12%

How Many Alexus Solar ALEX-545-B-72-S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Alexus Solar ALEX-545-B-72-S (55.07 V at 14 F).

Computed from Voc=49.68V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.61 V 10 panels 566.1 V 17 panels
-10 C (14 F) 55.07 V 10 panels 550.7 V 18 panels
0 C (32 F) 53.53 V 11 panels 588.8 V 18 panels
25 C (77 F STC) 49.68 V 12 panels 596.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Alexus Solar ALEX-545-B-72-S?

Competing CEC solar panels closest to Alexus Solar ALEX-545-B-72-S in nameplate wattage and Voc, starting with Exiom Solution S A EX550-144MH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Exiom Solution S A EX550-144MH
Exiom Solution S A
545.0 W Tie (0 W) 49.8 V 21.46% 92.5%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Alexus Solar ALEX-545-B-72-S?

Evaluate Alexus Solar ALEX-545-B-72-S (545.0 W STC, 49.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Alexus Solar ALEX-545-B-72-S reaches 56.61 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Alexus Solar ALEX-545-B-72-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Alexus Solar ALEX-545-B-72-S 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Exiom Solution S A EX550-144MH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 504.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Alexus Solar ALEX-545-B-72-S by Alexus Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Alexus Solar ALEX-545-B-72-S?

Multiplying Alexus Solar ALEX-545-B-72-S's 13.91 A short-circuit current by 1.56 equals 21.7 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Alexus Solar ALEX-545-B-72-S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.07 V cold Voc at 14 F and handles 13.91 A Isc; string inverters cap Alexus Solar ALEX-545-B-72-S at 10 panels on 600 V.

Is Alexus Solar ALEX-545-B-72-S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Alexus Solar ALEX-545-B-72-S rely on utility bill offset (~$2,047/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.