Skip to main content
WireAndSun
Calculators
CEC PV Module

CertainTeed CTM10405HC11-06 — CEC Solar Module Specifications

Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed CTM10405HC11-06 is a 405.0 W STC (379.7 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 37.23 V Voc at 25 C, and 40.77 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
379.7 W
Voc @ 25C
37.23 V
Efficiency
20.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed CTM10405HC11-06 Compare Against Peer CEC Listings?

Solar engineering breakdown for CertainTeed CTM10405HC11-06: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Measured at 405.0 W STC and 379.7 W PTC, CertainTeed CTM10405HC11-06 sits +20.0 W vs all-CEC median (top 43.4%; higher than 56.6% of peers) among 21,677 listed modules. Power density reaches 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). Lower 37.23 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer AMPS Solar AMPS-405P-54BB rates 405.0 W.

Where Does CertainTeed CTM10405HC11-06 Fall Across Listed CEC Models?

Distribution marker showing CertainTeed CTM10405HC11-06 (405.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed CTM10405HC11-06 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed CTM104: 405.0 W

What Dataset Percentiles Define CertainTeed CTM10405HC11-06?

Dataset percentiles tracking CertainTeed CTM10405HC11-06 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

CertainTeed CTM10405HC11-06 Engineering BenchmarksPercentile comparison of CertainTeed CTM10405HC11-06 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.8%Module Efficiency20.77%

What Do the Dataset Ranks Show for CertainTeed CTM10405HC11-06?

Benchmark highlights for CertainTeed CTM10405HC11-06 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.77 V at -10 C (570.8 V string) and 41.79 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,594 W PTC; NEC 690.8 OCPD floor is 21.64 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.23 * (1 + (-0.272/100) * (-10 - 25)) = 40.77 V | OCPD = 1.56 * 13.87 = 21.64 A

Inputs from CEC Modules.csv for CertainTeed CTM10405HC11-06: Voc=37.23 V, beta_Voc=-0.272%/C, Isc=13.87 A, STC=405.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (570.8 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for CertainTeed CTM10405HC11-06?

Official CEC datasheet figures for CertainTeed CTM10405HC11-06 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed CTM10405HC11-06.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 379.7 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.23 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.87 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.21 V / 12.98 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.77% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many CertainTeed CTM10405HC11-06 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CertainTeed CTM10405HC11-06 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 315 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 420 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 525 sq ft $2,533 $4,283

How Many CertainTeed CTM10405HC11-06 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed CTM10405HC11-06 (40.77 V at 14 F). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Computed from Voc=37.23V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.79 V 14 panels 585.1 V 23 panels
-10 C (14 F) 40.77 V 14 panels 570.8 V 24 panels
0 C (32 F) 39.76 V 15 panels 596.4 V 25 panels
25 C (77 F STC) 37.23 V 16 panels 595.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed CTM10405HC11-06?

Competing CEC solar panels closest to CertainTeed CTM10405HC11-06 in nameplate wattage and Voc, starting with AMPS Solar AMPS-405P-54BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
405.0 W Tie (0 W) 37.2 V 20.77% 93.8%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed CTM10405HC11-06?

Evaluate CertainTeed CTM10405HC11-06 (405.0 W STC, 37.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CTM10405HC11-06 reaches 41.79 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CertainTeed CTM10405HC11-06 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed CTM10405HC11-06 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AMPS Solar AMPS-405P-54BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed CTM10405HC11-06 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many CertainTeed CTM10405HC11-06 panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed CTM10405HC11-06 cold Voc rises from 37.23 V to 40.77 V (beta_Voc -0.272%/C), capping a 600 V string at 14 panels (570.8 V).

How much roof area does an 8 kW array of CertainTeed CTM10405HC11-06 need?

An 8 kW DC system uses 20 CertainTeed CTM10405HC11-06 modules (8,100 W STC / 7,594 W PTC), covering roughly 420 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does CertainTeed CTM10405HC11-06 compare against AMPS Solar AMPS-405P-54BB?

CertainTeed CTM10405HC11-06 outputs 405.0 W STC (37.23 V Voc, rank #8,961 of 21,677), while AMPS Solar AMPS-405P-54BB delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.