AMPS Solar AMPS-405P-54BB — CEC Solar Module Specifications

Manufacturer: AMPS Solar Registry: CEC Verified Engineering Specification

AMPS Solar AMPS-405P-54BB is a 405.0 W STC (381.7 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.88% efficiency, 37.25 V Voc at 25 C, and 40.69 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
381.7 W
Voc @ 25C
37.25 V
Efficiency
20.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AMPS Solar AMPS-405P-54BB Compare Against Peer CEC Listings?

How AMPS Solar AMPS Solar AMPS-405P-54BB handles rooftop heat (381.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AMPS Solar AMPS-405P-54BB exhibits 13.86 A short-circuit current, requiring a 21.62 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,961 of 21,677 (5.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does AMPS Solar AMPS-405P-54BB Fall Across Listed CEC Models?

Where AMPS Solar AMPS-405P-54BB (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AMPS Solar AMPS-405P-54BB (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAMPS Solar AMPS-40: 405.0 W

What Dataset Percentiles Define AMPS Solar AMPS-405P-54BB?

Percentile placement of AMPS Solar AMPS-405P-54BB across power density (208.8 W/m2), thermal retention, and nameplate STC wattage.

AMPS Solar AMPS-405P-54BB Engineering BenchmarksPercentile comparison of AMPS Solar AMPS-405P-54BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention94.2%Module Efficiency20.88%

What Do the Dataset Ranks Show for AMPS Solar AMPS-405P-54BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing AMPS Solar AMPS-405P-54BB specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.69 V at -10 C (569.7 V string) and 41.68 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.264/100) * (-10 - 25)) = 40.69 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-405P-54BB: Voc=37.25 V, beta_Voc=-0.264%/C, Isc=13.86 A, STC=405.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (569.7 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for AMPS Solar AMPS-405P-54BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AMPS Solar AMPS-405P-54BB.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-405P-54BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.7 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.25 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.24 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.264 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.88% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many AMPS Solar AMPS-405P-54BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AMPS Solar AMPS-405P-54BB (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 313 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 418 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 522 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This AMPS Solar Series?

All closely matched AMPS Solar wattages and cosmetic trims sharing the AMPS Solar AMPS-405P-54BB architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the AMPS Solar AMPS-405P-54BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AMPS Solar AMPS-400P-54BB 400.0 W 376.9 W 37.0 V 31.05 V 20.62%
AMPS Solar AMPS-405P-54BB 405.0 W 381.7 W 37.25 V 31.24 V 20.88%
AMPS Solar AMPS-410P-54BB 410.0 W 386.5 W 37.5 V 31.43 V 21.13%

How Many AMPS Solar AMPS-405P-54BB Modules Fit in a Cold-Weather String?

Maximum series module counts for AMPS Solar AMPS-405P-54BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.264%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.68 V 14 panels 583.5 V 23 panels
-10 C (14 F) 40.69 V 14 panels 569.7 V 24 panels
0 C (32 F) 39.71 V 15 panels 595.6 V 25 panels
25 C (77 F STC) 37.25 V 16 panels 596.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-405P-54BB?

Alternative CEC solar modules from competing brands near AMPS Solar AMPS-405P-54BB (405.0 W), including CertainTeed CTM10405HC11-06. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10405HC11-06
CertainTeed
405.0 W Tie (0 W) 37.23 V 20.77% 93.8%
Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
405.0 W Tie (0 W) 37.2 V 20.77% 93.8%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-405P-54BB?

Evaluate AMPS Solar AMPS-405P-54BB (405.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-405P-54BB reaches 41.68 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-405P-54BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AMPS Solar AMPS-405P-54BB 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10405HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-405P-54BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AMPS Solar AMPS-405P-54BB PTC wattage (381.7 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 381.7 W PTC (94.2% retention) across AMPS Solar AMPS-405P-54BB's 1.94 m2 aperture.

Who should skip AMPS Solar AMPS-405P-54BB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 AMPS Solar AMPS-405P-54BB panels (418 sq ft) leave unusable roof gaps vs. CertainTeed CTM10405HC11-06.

What is the 1,000 V commercial string limit for AMPS Solar AMPS-405P-54BB?

On 1,000 V commercial inverters at -10 C (40.69 V cold Voc), AMPS Solar AMPS-405P-54BB fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AMPS Solar AMPS-405P-54BB.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.