AMPS Solar AMPS-585N-144SW — CEC Solar Module Specifications

Manufacturer: AMPS Solar Registry: CEC Verified Engineering Specification

AMPS Solar AMPS-585N-144SW is a 585.0 W STC (555.2 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 52.7 V Voc at 25 C, and 56.96 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
555.2 W
Voc @ 25C
52.7 V
Efficiency
22.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AMPS Solar AMPS-585N-144SW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AMPS Solar AMPS-585N-144SW (Mono-c-Si) residential solar systems.

Homeowners evaluating AMPS Solar AMPS-585N-144SW need 11 panels for 6 kW or 14 panels (386 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.231%/C) pushes open-circuit voltage to 56.96 V at 14 F and 58.18 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does AMPS Solar AMPS-585N-144SW Fall Across Listed CEC Models?

Comparison of AMPS Solar AMPS-585N-144SW (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AMPS Solar AMPS-585N-144SW (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAMPS Solar AMPS-58: 585.0 W

What Dataset Percentiles Define AMPS Solar AMPS-585N-144SW?

Relative ranking of AMPS Solar AMPS-585N-144SW across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AMPS Solar AMPS-585N-144SW Engineering BenchmarksPercentile comparison of AMPS Solar AMPS-585N-144SW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention94.9%Module Efficiency22.85%

What Do the Dataset Ranks Show for AMPS Solar AMPS-585N-144SW?

Summary of AMPS Solar AMPS-585N-144SW output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,413

22.85% Aperture Efficiency

Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.96 V at -10 C (569.6 V string) and 58.18 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,773 W PTC; NEC 690.8 OCPD floor is 21.86 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.7 * (1 + (-0.231/100) * (-10 - 25)) = 56.96 V | OCPD = 1.56 * 14.01 = 21.86 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-585N-144SW: Voc=52.7 V, beta_Voc=-0.231%/C, Isc=14.01 A, STC=585.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (569.6 V); 14 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for AMPS Solar AMPS-585N-144SW?

Complete CEC test sheet for AMPS Solar AMPS-585N-144SW including Isc (14.01 A), Voc (52.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-585N-144SW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 555.2 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.01 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.02 V / 13.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.231 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.85% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many AMPS Solar AMPS-585N-144SW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AMPS Solar AMPS-585N-144SW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 303 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 386 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 496 sq ft $2,636 $4,457

Which Sibling Wattage & Trim Variants Belong to This AMPS Solar Series?

Related AMPS Solar power steps and black/silver trims consolidated into this AMPS Solar AMPS-585N-144SW series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the AMPS Solar AMPS-585N-144SW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AMPS Solar AMPS-575N-144SW 575.0 W 545.5 W 52.3 V 43.73 V 22.46%
AMPS Solar AMPS-580N-144SW 580.0 W 550.3 W 52.5 V 43.88 V 22.66%
AMPS Solar AMPS-585N-144SW 585.0 W 555.2 W 52.7 V 44.02 V 22.85%
AMPS Solar AMPS-590N-144SW 590.0 W 560.0 W 52.9 V 44.17 V 23.05%
AMPS Solar AMPS-595N-144SW 595.0 W 564.9 W 53.1 V 44.31 V 23.24%

How Many AMPS Solar AMPS-585N-144SW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AMPS Solar AMPS-585N-144SW (52.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.7V and beta_Voc=-0.231%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.18 V 10 panels 581.8 V 17 panels
-10 C (14 F) 56.96 V 10 panels 569.6 V 17 panels
0 C (32 F) 55.74 V 10 panels 557.4 V 17 panels
25 C (77 F STC) 52.7 V 11 panels 579.7 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-585N-144SW?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF (585.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF
Boviet Solar Technology Co Ltd
585.0 W Tie (0 W) 52.61 V 22.67% 95.1%
Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG
Boviet Solar Technology Co Ltd
585.0 W Tie (0 W) 52.61 V 22.67% 95.1%
CSI Solar Co Ltd CS6W-585TB-AG
CSI Solar Co Ltd
585.0 W Tie (0 W) 52.4 V 23.31% 95.0%
FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585
FS GREEN ENERGIES PRIVATE LIMITED
585.0 W Tie (0 W) 53.1 V 22.85% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-585N-144SW?

Evaluate AMPS Solar AMPS-585N-144SW (585.0 W STC, 52.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-585N-144SW reaches 58.18 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-585N-144SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AMPS Solar AMPS-585N-144SW 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 555.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-585N-144SW by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AMPS Solar AMPS-585N-144SW PTC wattage (555.2 W) lower than STC (585.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 555.2 W PTC (94.9% retention) across AMPS Solar AMPS-585N-144SW's 2.56 m2 aperture.

Who should skip AMPS Solar AMPS-585N-144SW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 AMPS Solar AMPS-585N-144SW panels (386 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF.

What is the 1,000 V commercial string limit for AMPS Solar AMPS-585N-144SW?

On 1,000 V commercial inverters at -10 C (56.96 V cold Voc), AMPS Solar AMPS-585N-144SW fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AMPS Solar AMPS-585N-144SW.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.