AMPS Solar AMPS-550P-144SW is a 550.0 W STC (518.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.05 V Voc at 25 C, and 53.39 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 518.4 W
- Voc @ 25C
- 49.05 V
- Efficiency
- 21.48%
How Does AMPS Solar AMPS-550P-144SW Compare Against Peer CEC Listings?
Engineering position of AMPS Solar AMPS-550P-144SW (550.0 W STC) vs. Apollo Renewables Inc Apollo-M772BH-550TW across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, AMPS Solar AMPS-550P-144SW pairs strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677) with 49.05 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,776 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Apollo Renewables Inc Apollo-M772BH-550TW offers a 550.0 W alternative.
Where Does AMPS Solar AMPS-550P-144SW Fall Across Listed CEC Models?
Plots AMPS Solar AMPS-550P-144SW at 550.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AMPS Solar AMPS-550P-144SW?
Benchmarks AMPS Solar AMPS-550P-144SW on STC wattage, thermal PTC/STC retention, and 21.48 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AMPS Solar AMPS-550P-144SW?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AMPS Solar AMPS-550P-144SW by AMPS Solar.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.48% Aperture Efficiency
Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.39 V at -10 C (587.3 V string) and 54.63 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,776 W PTC; NEC 690.8 OCPD floor is 22.12 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.05 * (1 + (-0.253/100) * (-10 - 25)) = 53.39 V | OCPD = 1.56 * 14.18 = 22.12 A
Inputs from CEC Modules.csv for AMPS Solar AMPS-550P-144SW: Voc=49.05 V, beta_Voc=-0.253%/C, Isc=14.18 A, STC=550.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (587.3 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for AMPS Solar AMPS-550P-144SW?
Laboratory test ratings recorded for AMPS Solar AMPS-550P-144SW (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 518.4 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.55 V / 13.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.253 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.48% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many AMPS Solar AMPS-550P-144SW Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for AMPS Solar AMPS-550P-144SW.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |
How Many AMPS Solar AMPS-550P-144SW Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AMPS Solar AMPS-550P-144SW (beta_Voc -0.253%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.63 V | 10 panels | 546.3 V | 18 panels |
| -10 C (14 F) | 53.39 V | 11 panels | 587.3 V | 18 panels |
| 0 C (32 F) | 52.15 V | 11 panels | 573.6 V | 19 panels |
| 25 C (77 F STC) | 49.05 V | 12 panels | 588.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-550P-144SW?
Closest cross-brand CEC competitors to AMPS Solar AMPS-550P-144SW matched near 550.0 W STC and 49.05 V Voc, led by Apollo Renewables Inc Apollo-M772BH-550TW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M772BH-550TW Apollo Renewables Inc |
550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| Exiom Solution S A EX550-144BMH-DG Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| Exiom Solution S A EX550-144M-BMH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
| Bluesun Solar CoLtd BSM550M10-72HBD Bluesun Solar CoLtd |
550.0 W | Tie (0 W) | 49.92 V | 21.23% | 92.4% |
What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-550P-144SW?
Evaluate AMPS Solar AMPS-550P-144SW (550.0 W STC, 49.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-550P-144SW reaches 54.63 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-550P-144SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AMPS Solar AMPS-550P-144SW 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M772BH-550TW.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 518.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AMPS Solar AMPS-550P-144SW by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AMPS Solar AMPS-550P-144SW?
Multiplying AMPS Solar AMPS-550P-144SW's 14.18 A short-circuit current by 1.56 equals 22.12 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can AMPS Solar AMPS-550P-144SW pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.39 V cold Voc at 14 F and handles 14.18 A Isc; string inverters cap AMPS Solar AMPS-550P-144SW at 11 panels on 600 V.
Is AMPS Solar AMPS-550P-144SW eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AMPS Solar AMPS-550P-144SW rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)