Apollo Renewables Inc Apollo-M772BH-550TW is a 550.0 W STC (514.6 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.9 V Voc at 25 C, and 54.91 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 514.6 W
- Voc @ 25C
- 49.9 V
- Efficiency
- 21.48%
How Does Apollo Renewables Inc Apollo-M772BH-550TW Compare Against Peer CEC Listings?
How Apollo Renewables Inc Apollo Renewables Inc Apollo-M772BH-550TW handles rooftop heat (514.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Apollo Renewables Inc Apollo-M772BH-550TW exhibits 14.0 A short-circuit current, requiring a 21.84 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,737 of 21,677 (140.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Apollo Renewables Inc Apollo-M772BH-550TW Fall Across Listed CEC Models?
Where Apollo Renewables Inc Apollo-M772BH-550TW (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Apollo Renewables Inc Apollo-M772BH-550TW?
Percentile placement of Apollo Renewables Inc Apollo-M772BH-550TW across power density (214.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Apollo Renewables Inc Apollo-M772BH-550TW?
Four critical engineering numbers homeowners and solar installers check first when reviewing Apollo Renewables Inc Apollo-M772BH-550TW specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.48% Aperture Efficiency
Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.91 V at -10 C (549.1 V string) and 56.34 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,719 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.9 * (1 + (-0.287/100) * (-10 - 25)) = 54.91 V | OCPD = 1.56 * 14.0 = 21.84 A
Inputs from CEC Modules.csv for Apollo Renewables Inc Apollo-M772BH-550TW: Voc=49.9 V, beta_Voc=-0.287%/C, Isc=14.0 A, STC=550.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (549.1 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Apollo Renewables Inc Apollo-M772BH-550TW?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Apollo Renewables Inc Apollo-M772BH-550TW.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 514.6 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.96 V / 13.11 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.287 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.48% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Apollo Renewables Inc Apollo-M772BH-550TW Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Apollo Renewables Inc Apollo-M772BH-550TW (550.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |
How Many Apollo Renewables Inc Apollo-M772BH-550TW Modules Fit in a Cold-Weather String?
Maximum series module counts for Apollo Renewables Inc Apollo-M772BH-550TW from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.34 V | 10 panels | 563.4 V | 17 panels |
| -10 C (14 F) | 54.91 V | 10 panels | 549.1 V | 18 panels |
| 0 C (32 F) | 53.48 V | 11 panels | 588.3 V | 18 panels |
| 25 C (77 F STC) | 49.9 V | 12 panels | 598.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Apollo Renewables Inc Apollo-M772BH-550TW?
Alternative CEC solar modules from competing brands near Apollo Renewables Inc Apollo-M772BH-550TW (550.0 W), including AMPS Solar AMPS-550P-144BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-550P-144BB AMPS Solar |
550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| Exiom Solution S A EX550-144BMH-DG Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| Exiom Solution S A EX550-144M-BMH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
| Bluesun Solar CoLtd BSM550M10-72HBD Bluesun Solar CoLtd |
550.0 W | Tie (0 W) | 49.92 V | 21.23% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Apollo Renewables Inc Apollo-M772BH-550TW?
Evaluate Apollo Renewables Inc Apollo-M772BH-550TW (550.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Apollo Renewables Inc Apollo-M772BH-550TW reaches 56.34 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Apollo Renewables Inc Apollo-M772BH-550TW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Apollo Renewables Inc Apollo-M772BH-550TW 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 514.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Apollo Renewables Inc Apollo-M772BH-550TW by Apollo Renewables Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Apollo Renewables Inc Apollo-M772BH-550TW PTC wattage (514.6 W) lower than STC (550.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 514.6 W PTC (93.6% retention) across Apollo Renewables Inc Apollo-M772BH-550TW's 2.56 m2 aperture.
Who should skip Apollo Renewables Inc Apollo-M772BH-550TW on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Apollo Renewables Inc Apollo-M772BH-550TW panels (413 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-550P-144BB.
What is the 1,000 V commercial string limit for Apollo Renewables Inc Apollo-M772BH-550TW?
On 1,000 V commercial inverters at -10 C (54.91 V cold Voc), Apollo Renewables Inc Apollo-M772BH-550TW fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Apollo Renewables Inc Apollo-M772BH-550TW.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)