Heliene 132HC-485 M10 SL is a 485.0 W STC (457.2 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 21.18% efficiency, 45.77 V Voc at 25 C, and 49.77 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 485.0 W
- PTC Wattage
- 457.2 W
- Voc @ 25C
- 45.77 V
- Efficiency
- 21.18%
How Does Heliene 132HC-485 M10 SL Compare Against Peer CEC Listings?
How Heliene Heliene 132HC-485 M10 SL handles rooftop heat (457.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Heliene 132HC-485 M10 SL exhibits 13.28 A short-circuit current, requiring a 20.72 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,730 of 21,677 (75.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.9 m2 for an 8 kW system (21 panels for 10 kW). Mid-range 45.77 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Heliene 132HC-485 M10 SL Fall Across Listed CEC Models?
Where Heliene 132HC-485 M10 SL (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 132HC-485 M10 SL?
Percentile placement of Heliene 132HC-485 M10 SL across power density (211.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Heliene 132HC-485 M10 SL?
Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 132HC-485 M10 SL specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Top 22.2% STC Output
485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.18% Aperture Efficiency
Power density 211.8 W/m2 (1.27 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.77 V at -10 C (597.2 V string) and 50.92 V at -20 C (11 max).
17 Panels = 8,245 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,772 W PTC; NEC 690.8 OCPD floor is 20.72 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.77 * (1 + (-0.25/100) * (-10 - 25)) = 49.77 V | OCPD = 1.56 * 13.28 = 20.72 A
Inputs from CEC Modules.csv for Heliene 132HC-485 M10 SL: Voc=45.77 V, beta_Voc=-0.25%/C, Isc=13.28 A, STC=485.0 W, Area=2.29 m2.
Result: 12 panels max on 600 V (597.2 V); 17 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for Heliene 132HC-485 M10 SL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 132HC-485 M10 SL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 457.2 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.49 V / 12.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.25 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.18% (2.29 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 132HC-485 M10 SL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 132HC-485 M10 SL (485.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.3 kW | 320 sq ft | $1,577 | $2,666 |
| 8 kW Class | 17 | 8.24 kW | 419 sq ft | $2,062 | $3,487 |
| 10 kW Class | 21 | 10.19 kW | 518 sq ft | $2,550 | $4,313 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
All closely matched Heliene wattages and cosmetic trims sharing the Heliene 132HC-485 M10 SL architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 132HC-475 M10 SL | 475.0 W | 447.6 W | 45.4 V | 37.9 V | 20.74% |
| Heliene 132HC-480 M10 SL | 480.0 W | 452.4 W | 45.57 V | 38.22 V | 20.96% |
| Heliene 132HC-485 M10 SL | 485.0 W | 457.2 W | 45.77 V | 38.49 V | 21.18% |
| Heliene 132HC-490 M10 SL | 490.0 W | 462.1 W | 46.0 V | 38.88 V | 21.4% |
| Heliene 132HC-495 M10 SL | 495.0 W | 466.9 W | 46.21 V | 39.28 V | 21.62% |
How Many Heliene 132HC-485 M10 SL Modules Fit in a Cold-Weather String?
Maximum series module counts for Heliene 132HC-485 M10 SL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.92 V | 11 panels | 560.1 V | 19 panels |
| -10 C (14 F) | 49.77 V | 12 panels | 597.2 V | 20 panels |
| 0 C (32 F) | 48.63 V | 12 panels | 583.6 V | 20 panels |
| 25 C (77 F STC) | 45.77 V | 13 panels | 595.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 132HC-485 M10 SL?
Alternative CEC solar modules from competing brands near Heliene 132HC-485 M10 SL (485.0 W), including Auxin Solar AXN10M485B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M485B Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 92.0% |
| Auxin Solar AXN10M485W Auxin Solar |
485.0 W | Tie (0 W) | 43.98 V | 22.56% | 91.8% |
| Hanersun Energy Co Ltd HN18N-60HT485W Hanersun Energy Co Ltd |
485.0 W | Tie (0 W) | 43.0 V | 22.99% | 94.9% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
490.0 W | +5.0 W | 44.21 V | 25.79% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Heliene 132HC-485 M10 SL?
Evaluate Heliene 132HC-485 M10 SL (485.0 W STC, 45.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 132HC-485 M10 SL reaches 50.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 132HC-485 M10 SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 132HC-485 M10 SL 8 kW Residential Fit
Needs 17 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN10M485B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 457.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 132HC-485 M10 SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Heliene 132HC-485 M10 SL PTC wattage (457.2 W) lower than STC (485.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 457.2 W PTC (94.3% retention) across Heliene 132HC-485 M10 SL's 2.29 m2 aperture.
Who should skip Heliene 132HC-485 M10 SL on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Heliene 132HC-485 M10 SL panels (419 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M485B.
What is the 1,000 V commercial string limit for Heliene 132HC-485 M10 SL?
On 1,000 V commercial inverters at -10 C (49.77 V cold Voc), Heliene 132HC-485 M10 SL fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 132HC-485 M10 SL.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)