Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Energy Co Ltd HN18N-60HT485W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN18N-60HT485W is a 485.0 W STC (460.4 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.99% efficiency, 43.0 V Voc at 25 C, and 46.52 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
460.4 W
Voc @ 25C
43.0 V
Efficiency
22.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN18N-60HT485W Compare Against Peer CEC Listings?

Engineering position of Hanersun Energy Co Ltd HN18N-60HT485W (485.0 W STC) vs. CSI Solar Co Ltd CS61-60TM-485H across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Hanersun Energy Co Ltd HN18N-60HT485W pairs strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677) with 43.0 V nominal Voc. An 8 kW residential build (8,245 W DC, 7,827 W PTC) saves ~$2,062/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS61-60TM-485H offers a 485.0 W alternative.

Where Does Hanersun Energy Co Ltd HN18N-60HT485W Fall Across Listed CEC Models?

Plots Hanersun Energy Co Ltd HN18N-60HT485W at 485.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN18N-60HT485W (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 485.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN18N-60HT485W?

Benchmarks Hanersun Energy Co Ltd HN18N-60HT485W on STC wattage, thermal PTC/STC retention, and 22.99 aperture conversion efficiency against CEC peers.

Hanersun Energy Co Ltd HN18N-60HT485W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN18N-60HT485W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention94.9%Module Efficiency22.99%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18N-60HT485W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hanersun Energy Co Ltd HN18N-60HT485W by Hanersun Energy Co Ltd.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,167

22.99% Aperture Efficiency

Power density 229.9 W/m2 (3.08 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.52 V at -10 C (558.2 V string) and 47.53 V at -20 C (12 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 35.9 m2 (386 sq ft) producing 7,827 W PTC; NEC 690.8 OCPD floor is 22.21 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.0 * (1 + (-0.234/100) * (-10 - 25)) = 46.52 V | OCPD = 1.56 * 14.24 = 22.21 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18N-60HT485W: Voc=43.0 V, beta_Voc=-0.234%/C, Isc=14.24 A, STC=485.0 W, Area=2.11 m2.

Result: 12 panels max on 600 V (558.2 V); 17 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18N-60HT485W?

Laboratory test ratings recorded for Hanersun Energy Co Ltd HN18N-60HT485W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18N-60HT485W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 460.4 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.1 V / 13.44 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.99% (2.11 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN18N-60HT485W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hanersun Energy Co Ltd HN18N-60HT485W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 295 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 386 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 477 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Sibling wattage bins and frame colors grouped with Hanersun Energy Co Ltd HN18N-60HT485W under Hanersun Energy Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18N-60HT485W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN18N-60HT475W 475.0 W 450.7 W 42.6 V 35.7 V 22.51%
Hanersun Energy Co Ltd HN18N-60HT480W 480.0 W 455.6 W 42.8 V 35.9 V 22.75%
Hanersun Energy Co Ltd HN18N-60HT485W 485.0 W 460.4 W 43.0 V 36.1 V 22.99%
Hanersun Energy Co Ltd HN18N-60HT490W 490.0 W 465.3 W 43.2 V 36.3 V 23.22%
Hanersun Energy Co Ltd HN18N-60HT495W 495.0 W 470.1 W 43.4 V 36.5 V 23.46%

How Many Hanersun Energy Co Ltd HN18N-60HT485W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hanersun Energy Co Ltd HN18N-60HT485W (beta_Voc -0.234%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=43.0V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.53 V 12 panels 570.4 V 21 panels
-10 C (14 F) 46.52 V 12 panels 558.2 V 21 panels
0 C (32 F) 45.52 V 13 panels 591.8 V 21 panels
25 C (77 F STC) 43.0 V 13 panels 559.0 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18N-60HT485W?

Closest cross-brand CEC competitors to Hanersun Energy Co Ltd HN18N-60HT485W matched near 485.0 W STC and 43.0 V Voc, led by CSI Solar Co Ltd CS61-60TM-485H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS61-60TM-485H
CSI Solar Co Ltd
485.0 W Tie (0 W) 42.6 V 22.15% 94.7%
Auxin Solar AXN10M485B
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 92.0%
Auxin Solar AXN10M485W
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 91.8%
Aptos Solar Technology LLC DNA-120-BFN10-480W-DG
Aptos Solar Technology LLC
480.0 W -5.0 W 42.61 V 22.22% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18N-60HT485W?

Evaluate Hanersun Energy Co Ltd HN18N-60HT485W (485.0 W STC, 43.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18N-60HT485W reaches 47.53 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 386 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (386 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18N-60HT485W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN18N-60HT485W 8 kW Residential Fit

Needs 17 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS61-60TM-485H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 460.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18N-60HT485W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN18N-60HT485W?

Multiplying Hanersun Energy Co Ltd HN18N-60HT485W's 14.24 A short-circuit current by 1.56 equals 22.21 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Hanersun Energy Co Ltd HN18N-60HT485W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.52 V cold Voc at 14 F and handles 14.24 A Isc; string inverters cap Hanersun Energy Co Ltd HN18N-60HT485W at 12 panels on 600 V.

Is Hanersun Energy Co Ltd HN18N-60HT485W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN18N-60HT485W rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.