Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS61-60TM-485H — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS61-60TM-485H is a 485.0 W STC (459.2 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.15% efficiency, 42.6 V Voc at 25 C, and 46.28 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
459.2 W
Voc @ 25C
42.6 V
Efficiency
22.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS61-60TM-485H Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS61-60TM-485H handles rooftop heat (459.2 W PTC), 8 kW sizing, and cold winter string voltage.

CSI Solar Co Ltd builds the CSI Solar Co Ltd CS61-60TM-485H (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 221.5 W/m2 (2.24 percentage points above 19.91% CEC median). Compared against Hanersun Energy Co Ltd HN18N-60HT485W (485.0 W), this model holds strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Mid-range 42.6 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 22.31 A overcurrent floor served by a 25 A breaker.

Where Does CSI Solar Co Ltd CS61-60TM-485H Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS61-60TM-485H (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS61-60TM-485H (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 485.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS61-60TM-485H?

Percentile placement of CSI Solar Co Ltd CS61-60TM-485H across power density (221.5 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS61-60TM-485H Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS61-60TM-485H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention94.7%Module Efficiency22.15%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS61-60TM-485H?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS61-60TM-485H specifications.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,762

22.15% Aperture Efficiency

Power density 221.5 W/m2 (2.24 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.28 V at -10 C (555.4 V string) and 47.33 V at -20 C (12 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 37.2 m2 (401 sq ft) producing 7,806 W PTC; NEC 690.8 OCPD floor is 22.31 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.6 * (1 + (-0.247/100) * (-10 - 25)) = 46.28 V | OCPD = 1.56 * 14.3 = 22.31 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS61-60TM-485H: Voc=42.6 V, beta_Voc=-0.247%/C, Isc=14.3 A, STC=485.0 W, Area=2.19 m2.

Result: 12 panels max on 600 V (555.4 V); 17 panels for 8 kW (401 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS61-60TM-485H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS61-60TM-485H.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS61-60TM-485H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 459.2 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 13.49 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.15% (2.19 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS61-60TM-485H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS61-60TM-485H (485.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 306 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 401 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 495 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS61-60TM-485H architecture.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS61-60TM-485H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS61-60TM-475H 475.0 W 449.6 W 42.2 V 35.6 V 21.69%
CSI Solar Co Ltd CS61-60TM-480H 480.0 W 454.4 W 42.4 V 35.8 V 21.92%
CSI Solar Co Ltd CS61-60TM-485H 485.0 W 459.2 W 42.6 V 36.0 V 22.15%
CSI Solar Co Ltd CS61-60TM-490H 490.0 W 464.1 W 42.8 V 36.2 V 22.37%
CSI Solar Co Ltd CS61-60TM-495H 495.0 W 468.9 W 43.0 V 36.4 V 22.6%

How Many CSI Solar Co Ltd CS61-60TM-485H Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS61-60TM-485H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=42.6V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.33 V 12 panels 568.0 V 21 panels
-10 C (14 F) 46.28 V 12 panels 555.4 V 21 panels
0 C (32 F) 45.23 V 13 panels 588.0 V 22 panels
25 C (77 F STC) 42.6 V 14 panels 596.4 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS61-60TM-485H?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS61-60TM-485H (485.0 W), including Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanersun Energy Co Ltd HN18N-60HT485W
Hanersun Energy Co Ltd
485.0 W Tie (0 W) 43.0 V 22.99% 94.9%
Aptos Solar Technology LLC DNA-120-BFN10-480W-DG
Aptos Solar Technology LLC
480.0 W -5.0 W 42.61 V 22.22% 94.9%
Auxin Solar AXN10M485B
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 92.0%
Auxin Solar AXN10M485W
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS61-60TM-485H?

Evaluate CSI Solar Co Ltd CS61-60TM-485H (485.0 W STC, 42.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS61-60TM-485H reaches 47.33 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 401 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (401 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS61-60TM-485H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS61-60TM-485H 8 kW Residential Fit

Needs 17 modules (401 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 459.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS61-60TM-485H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS61-60TM-485H?

Multiplying CSI Solar Co Ltd CS61-60TM-485H's 14.3 A short-circuit current by 1.56 equals 22.31 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS61-60TM-485H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.28 V cold Voc at 14 F and handles 14.3 A Isc; string inverters cap CSI Solar Co Ltd CS61-60TM-485H at 12 panels on 600 V.

Is CSI Solar Co Ltd CS61-60TM-485H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS61-60TM-485H rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.