Auxin Solar AXN10M485B is a 485.0 W STC (446.4 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.56% efficiency, 43.98 V Voc at 25 C, and 48.14 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
446.4 W
Voc @ 25C
43.98 V
Efficiency
22.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M485B Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN10M485B (485.0 W STC) vs. Hanersun Energy Co Ltd HN18N-60HT485W across 5,889 CEC Mono-c-Si solar modules.

Ranking #4,730 across 21,677 CEC solar panels (top 22.2%; higher than 77.8% of peers), Auxin Solar AXN10M485B operates as a modern high-density residential and light-commercial module sitting 75.0 W above the 410.0 W Mono-c-Si median. Mid-range 43.98 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677), 17 panels occupy 393 sq ft and offset roughly $2,062/yr at average US rates (or $3,487/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN10M485B Fall Across Listed CEC Models?

Plots Auxin Solar AXN10M485B at 485.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M485B (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 485.0 W

What Dataset Percentiles Define Auxin Solar AXN10M485B?

Benchmarks Auxin Solar AXN10M485B on STC wattage, thermal PTC/STC retention, and 22.56 aperture conversion efficiency against CEC peers.

Auxin Solar AXN10M485B Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M485B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention92.0%Module Efficiency22.56%

What Do the Dataset Ranks Show for Auxin Solar AXN10M485B?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN10M485B by Auxin Solar.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,894

22.56% Aperture Efficiency

Power density 225.6 W/m2 (2.65 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.14 V at -10 C (577.7 V string) and 49.32 V at -20 C (12 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 36.5 m2 (393 sq ft) producing 7,589 W PTC; NEC 690.8 OCPD floor is 21.56 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.98 * (1 + (-0.27/100) * (-10 - 25)) = 48.14 V | OCPD = 1.56 * 13.82 = 21.56 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M485B: Voc=43.98 V, beta_Voc=-0.27%/C, Isc=13.82 A, STC=485.0 W, Area=2.15 m2.

Result: 12 panels max on 600 V (577.7 V); 17 panels for 8 kW (393 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M485B?

Laboratory test ratings recorded for Auxin Solar AXN10M485B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M485B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 446.4 W (92.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.03 V / 13.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.56% (2.15 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M485B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (393 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN10M485B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 301 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 393 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 486 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN10M485B under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN10M485B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M475B 475.0 W 435.3 W 43.85 V 36.9 V 22.09%
Auxin Solar AXN10M480B 480.0 W 441.7 W 43.91 V 36.97 V 22.33%
Auxin Solar AXN10M485B 485.0 W 446.4 W 43.98 V 37.03 V 22.56%
Auxin Solar AXN10M490B 490.0 W 451.2 W 44.04 V 37.1 V 22.79%

How Many Auxin Solar AXN10M485B Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN10M485B (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=43.98V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.32 V 12 panels 591.8 V 20 panels
-10 C (14 F) 48.14 V 12 panels 577.7 V 20 panels
0 C (32 F) 46.95 V 12 panels 563.4 V 21 panels
25 C (77 F STC) 43.98 V 13 panels 571.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M485B?

Closest cross-brand CEC competitors to Auxin Solar AXN10M485B matched near 485.0 W STC and 43.98 V Voc, led by Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanersun Energy Co Ltd HN18N-60HT485W
Hanersun Energy Co Ltd
485.0 W Tie (0 W) 43.0 V 22.99% 94.9%
CSI Solar Co Ltd CS61-60TM-485H
CSI Solar Co Ltd
485.0 W Tie (0 W) 42.6 V 22.15% 94.7%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
490.0 W +5.0 W 44.21 V 25.79% 95.0%
Heliene 132HC-485 M10 SL
Heliene
485.0 W Tie (0 W) 45.77 V 21.18% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M485B?

Evaluate Auxin Solar AXN10M485B (485.0 W STC, 43.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M485B reaches 49.32 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 393 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (393 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M485B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M485B 8 kW Residential Fit

Needs 17 modules (393 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 446.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M485B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN10M485B panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN10M485B cold Voc rises from 43.98 V to 48.14 V (beta_Voc -0.27%/C), capping a 600 V string at 12 panels (577.7 V).

How much roof area does an 8 kW array of Auxin Solar AXN10M485B need?

An 8 kW DC system uses 17 Auxin Solar AXN10M485B modules (8,245 W STC / 7,589 W PTC), covering roughly 393 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

How does Auxin Solar AXN10M485B compare against Hanersun Energy Co Ltd HN18N-60HT485W?

Auxin Solar AXN10M485B outputs 485.0 W STC (43.98 V Voc, rank #4,730 of 21,677), while Hanersun Energy Co Ltd HN18N-60HT485W delivers 485.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.