Auxin Solar AXN10M485W — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M485W is a 485.0 W STC (445.0 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.56% efficiency, 43.98 V Voc at 25 C, and 48.29 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
445.0 W
Voc @ 25C
43.98 V
Efficiency
22.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M485W Compare Against Peer CEC Listings?

How Auxin Solar Auxin Solar AXN10M485W handles rooftop heat (445.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Auxin Solar AXN10M485W exhibits 13.82 A short-circuit current, requiring a 21.56 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,730 of 21,677 (75.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 36.5 m2 for an 8 kW system (21 panels for 10 kW). Mid-range 43.98 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Auxin Solar AXN10M485W Fall Across Listed CEC Models?

Where Auxin Solar AXN10M485W (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M485W (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 485.0 W

What Dataset Percentiles Define Auxin Solar AXN10M485W?

Percentile placement of Auxin Solar AXN10M485W across power density (225.6 W/m2), thermal retention, and nameplate STC wattage.

Auxin Solar AXN10M485W Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M485W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention91.8%Module Efficiency22.56%

What Do the Dataset Ranks Show for Auxin Solar AXN10M485W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Auxin Solar AXN10M485W specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,894

22.56% Aperture Efficiency

Power density 225.6 W/m2 (2.65 percentage points above 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.29 V at -10 C (579.5 V string) and 49.52 V at -20 C (12 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 36.5 m2 (393 sq ft) producing 7,565 W PTC; NEC 690.8 OCPD floor is 21.56 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.98 * (1 + (-0.28/100) * (-10 - 25)) = 48.29 V | OCPD = 1.56 * 13.82 = 21.56 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M485W: Voc=43.98 V, beta_Voc=-0.28%/C, Isc=13.82 A, STC=485.0 W, Area=2.15 m2.

Result: 12 panels max on 600 V (579.5 V); 17 panels for 8 kW (393 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M485W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Auxin Solar AXN10M485W.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M485W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 445.0 W (91.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.03 V / 13.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.56% (2.15 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M485W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Auxin Solar AXN10M485W (485.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 301 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 393 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 486 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

All closely matched Auxin Solar wattages and cosmetic trims sharing the Auxin Solar AXN10M485W architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Auxin Solar AXN10M485W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M475W 475.0 W 437.1 W 43.85 V 36.9 V 22.09%
Auxin Solar AXN10M480W 480.0 W 441.8 W 43.91 V 36.97 V 22.33%
Auxin Solar AXN10M485W 485.0 W 445.0 W 43.98 V 37.03 V 22.56%
Auxin Solar AXN10M490W 490.0 W 449.8 W 44.04 V 37.1 V 22.79%
Auxin Solar AXN10M495W 495.0 W 454.5 W 44.1 V 37.17 V 23.02%

How Many Auxin Solar AXN10M485W Modules Fit in a Cold-Weather String?

Maximum series module counts for Auxin Solar AXN10M485W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.98V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.52 V 12 panels 594.2 V 20 panels
-10 C (14 F) 48.29 V 12 panels 579.5 V 20 panels
0 C (32 F) 47.06 V 12 panels 564.7 V 21 panels
25 C (77 F STC) 43.98 V 13 panels 571.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M485W?

Alternative CEC solar modules from competing brands near Auxin Solar AXN10M485W (485.0 W), including Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanersun Energy Co Ltd HN18N-60HT485W
Hanersun Energy Co Ltd
485.0 W Tie (0 W) 43.0 V 22.99% 94.9%
CSI Solar Co Ltd CS61-60TM-485H
CSI Solar Co Ltd
485.0 W Tie (0 W) 42.6 V 22.15% 94.7%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
490.0 W +5.0 W 44.21 V 25.79% 95.0%
Heliene 132HC-485 M10 SL
Heliene
485.0 W Tie (0 W) 45.77 V 21.18% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M485W?

Evaluate Auxin Solar AXN10M485W (485.0 W STC, 43.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M485W reaches 49.52 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 393 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (393 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M485W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M485W 8 kW Residential Fit

Needs 17 modules (393 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 445.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M485W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Auxin Solar AXN10M485W PTC wattage (445.0 W) lower than STC (485.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 445.0 W PTC (91.8% retention) across Auxin Solar AXN10M485W's 2.15 m2 aperture.

Who should skip Auxin Solar AXN10M485W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Auxin Solar AXN10M485W panels (393 sq ft) leave unusable roof gaps vs. Hanersun Energy Co Ltd HN18N-60HT485W.

What is the 1,000 V commercial string limit for Auxin Solar AXN10M485W?

On 1,000 V commercial inverters at -10 C (48.29 V cold Voc), Auxin Solar AXN10M485W fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN10M485W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.