Heliene 144HC-440 Bifacial is a 440.0 W STC (410.7 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 19.91% efficiency, 50.43 V Voc at 25 C, and 55.05 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 410.7 W
- Voc @ 25C
- 50.43 V
- Efficiency
- 19.91%
How Does Heliene 144HC-440 Bifacial Compare Against Peer CEC Listings?
Engineering position of Heliene 144HC-440 Bifacial (440.0 W STC) vs. Bluesun Solar CoLtd BSM440M-72HBD across 5,889 CEC Mono-c-Si solar modules.
Ranking #6,418 across 21,677 CEC solar panels (top 31.6%; higher than 68.4% of peers), Heliene 144HC-440 Bifacial operates as a modern high-density residential and light-commercial module sitting 30.0 W above the 410.0 W Mono-c-Si median. Higher 50.43 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), 19 panels occupy 452 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Heliene 144HC-440 Bifacial Fall Across Listed CEC Models?
Plots Heliene 144HC-440 Bifacial at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 144HC-440 Bifacial?
Benchmarks Heliene 144HC-440 Bifacial on STC wattage, thermal PTC/STC retention, and 19.91 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Heliene 144HC-440 Bifacial?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 144HC-440 Bifacial by Heliene.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.91% Aperture Efficiency
Power density 199.1 W/m2 (equal to 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.05 V at -10 C (550.5 V string) and 56.38 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,803 W PTC; NEC 690.8 OCPD floor is 17.43 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.43 * (1 + (-0.262/100) * (-10 - 25)) = 55.05 V | OCPD = 1.56 * 11.17 = 17.43 A
Inputs from CEC Modules.csv for Heliene 144HC-440 Bifacial: Voc=50.43 V, beta_Voc=-0.262%/C, Isc=11.17 A, STC=440.0 W, Area=2.21 m2.
Result: 10 panels max on 600 V (550.5 V); 19 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for Heliene 144HC-440 Bifacial?
Laboratory test ratings recorded for Heliene 144HC-440 Bifacial (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 410.7 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.43 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.93 V / 10.51 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.91% (2.21 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Heliene 144HC-440 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (452 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 144HC-440 Bifacial.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 333 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 452 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 547 sq ft | $2,533 | $4,283 |
How Many Heliene 144HC-440 Bifacial Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Heliene 144HC-440 Bifacial (beta_Voc -0.262%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.38 V | 10 panels | 563.8 V | 17 panels |
| -10 C (14 F) | 55.05 V | 10 panels | 550.5 V | 18 panels |
| 0 C (32 F) | 53.73 V | 11 panels | 591.0 V | 18 panels |
| 25 C (77 F STC) | 50.43 V | 11 panels | 554.7 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-440 Bifacial?
Closest cross-brand CEC competitors to Heliene 144HC-440 Bifacial matched near 440.0 W STC and 50.43 V Voc, led by Bluesun Solar CoLtd BSM440M-72HBD.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM440M-72HBD Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 50.0 V | 20.28% | 92.7% |
| CSI Solar Co Ltd CS3Y-440PB-AG CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 51.2 V | 19.13% | 93.7% |
| Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi Bright Spot Solar LLC |
445.0 W | +5.0 W | 50.6 V | 20.14% | 93.5% |
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | -5.0 W | 49.38 V | 20.71% | 92.3% |
What Are the Design Limits and Best-Fit Uses for Heliene 144HC-440 Bifacial?
Evaluate Heliene 144HC-440 Bifacial (440.0 W STC, 50.43 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-440 Bifacial reaches 56.38 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 144HC-440 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 144HC-440 Bifacial 8 kW Residential Fit
Needs 19 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM440M-72HBD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 410.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 144HC-440 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
How many Heliene 144HC-440 Bifacial panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 144HC-440 Bifacial cold Voc rises from 50.43 V to 55.05 V (beta_Voc -0.262%/C), capping a 600 V string at 10 panels (550.5 V).
How much roof area does an 8 kW array of Heliene 144HC-440 Bifacial need?
An 8 kW DC system uses 19 Heliene 144HC-440 Bifacial modules (8,360 W STC / 7,803 W PTC), covering roughly 452 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Heliene 144HC-440 Bifacial compare against Bluesun Solar CoLtd BSM440M-72HBD?
Heliene 144HC-440 Bifacial outputs 440.0 W STC (50.43 V Voc, rank #6,418 of 21,677), while Bluesun Solar CoLtd BSM440M-72HBD delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)