Heliene 120HC-380 is a 380.0 W STC (356.7 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.77% efficiency, 41.6 V Voc at 25 C, and 45.55 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 356.7 W
- Voc @ 25C
- 41.6 V
- Efficiency
- 20.77%
How Does Heliene 120HC-380 Compare Against Peer CEC Listings?
How Heliene Heliene 120HC-380 handles rooftop heat (356.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Heliene 120HC-380 exhibits 11.92 A short-circuit current, requiring a 18.6 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 40.3 m2 for an 8 kW system (27 panels for 10 kW). Mid-range 41.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Heliene 120HC-380 Fall Across Listed CEC Models?
Where Heliene 120HC-380 (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 120HC-380?
Percentile placement of Heliene 120HC-380 across power density (207.7 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for Heliene 120HC-380?
Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 120HC-380 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.77% Aperture Efficiency
Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.55 V at -10 C (592.1 V string) and 46.67 V at -20 C (12 max).
22 Panels = 8,360 W STC
Occupies 40.3 m2 (433 sq ft) producing 7,847 W PTC; NEC 690.8 OCPD floor is 18.6 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.6 * (1 + (-0.271/100) * (-10 - 25)) = 45.55 V | OCPD = 1.56 * 11.92 = 18.6 A
Inputs from CEC Modules.csv for Heliene 120HC-380: Voc=41.6 V, beta_Voc=-0.271%/C, Isc=11.92 A, STC=380.0 W, Area=1.83 m2.
Result: 13 panels max on 600 V (592.1 V); 22 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for Heliene 120HC-380?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 120HC-380. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 356.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.4 V / 10.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.77% (1.83 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 120HC-380 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 120HC-380 (380.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 433 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 532 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
All closely matched Heliene wattages and cosmetic trims sharing the Heliene 120HC-380 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 120HC-375 | 375.0 W | 351.9 W | 41.4 V | 35.26 V | 20.49% |
| Heliene 120HC-380 | 380.0 W | 356.7 W | 41.6 V | 35.4 V | 20.77% |
How Many Heliene 120HC-380 Modules Fit in a Cold-Weather String?
Maximum series module counts for Heliene 120HC-380 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.67 V | 12 panels | 560.0 V | 21 panels |
| -10 C (14 F) | 45.55 V | 13 panels | 592.1 V | 21 panels |
| 0 C (32 F) | 44.42 V | 13 panels | 577.5 V | 22 panels |
| 25 C (77 F STC) | 41.6 V | 14 panels | 582.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 120HC-380?
Alternative CEC solar modules from competing brands near Heliene 120HC-380 (380.0 W), including DualSun SAS DualSun 380M-120-01. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 380M-120-01 DualSun SAS |
380.0 W | Tie (0 W) | 41.3 V | 21.47% | 93.9% |
| Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC Boviet Solar Technology Co Ltd |
380.0 W | Tie (0 W) | 40.94 V | 20.54% | 94.2% |
| CSI Solar Co Ltd CS3L-385MS CSI Solar Co Ltd |
385.0 W | +5.0 W | 41.4 V | 21.51% | 93.2% |
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | -5.0 W | 41.2 V | 20.95% | 92.5% |
What Are the Design Limits and Best-Fit Uses for Heliene 120HC-380?
Evaluate Heliene 120HC-380 (380.0 W STC, 41.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 120HC-380 reaches 46.67 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 120HC-380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 120HC-380 8 kW Residential Fit
Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 120HC-380 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Why is Heliene 120HC-380 PTC wattage (356.7 W) lower than STC (380.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 356.7 W PTC (93.9% retention) across Heliene 120HC-380's 1.83 m2 aperture.
Who should skip Heliene 120HC-380 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Heliene 120HC-380 panels (433 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 380M-120-01.
What is the 1,000 V commercial string limit for Heliene 120HC-380?
On 1,000 V commercial inverters at -10 C (45.55 V cold Voc), Heliene 120HC-380 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 120HC-380.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)