Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 60P220 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 60P220 is a 220.0 W STC (194.8 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.23% efficiency, 36.6 V Voc at 25 C, and 40.65 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
220.0 W
PTC Wattage
194.8 W
Voc @ 25C
36.6 V
Efficiency
13.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 60P220 Compare Against Peer CEC Listings?

How Heliene Heliene 60P220 handles rooftop heat (194.8 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 60P220 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 132.3 W/m2 (6.68 percentage points below 19.91% CEC median). Compared against Grape Solar GS-P-220-CS (220.0 W), this model holds typical 88.5% PTC-to-STC thermal output (194.8 W real-world rating). Lower 36.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.76 A overcurrent floor served by a 15 A breaker.

Where Does Heliene 60P220 Fall Across Listed CEC Models?

Where Heliene 60P220 (220.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 60P220 (220.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 60P220: 220.0 W

What Dataset Percentiles Define Heliene 60P220?

Percentile placement of Heliene 60P220 across power density (132.3 W/m2), thermal retention, and nameplate STC wattage. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Heliene 60P220 Engineering BenchmarksPercentile comparison of Heliene 60P220 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage220.0 WPTC/STC Retention88.5%Module Efficiency13.23%

What Do the Dataset Ranks Show for Heliene 60P220?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 60P220 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #20,759 / 21,677

220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,339

13.23% Aperture Efficiency

Power density 132.3 W/m2 (6.68 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.65 V at -10 C (569.1 V string) and 41.8 V at -20 C (14 max).

8 kW Reference Array

37 Panels = 8,140 W STC

Occupies 61.5 m2 (662 sq ft) producing 7,208 W PTC; NEC 690.8 OCPD floor is 12.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.6 * (1 + (-0.316/100) * (-10 - 25)) = 40.65 V | OCPD = 1.56 * 8.18 = 12.76 A

Inputs from CEC Modules.csv for Heliene 60P220: Voc=36.6 V, beta_Voc=-0.316%/C, Isc=8.18 A, STC=220.0 W, Area=1.663 m2.

Result: 14 panels max on 600 V (569.1 V); 37 panels for 8 kW (662 sq ft).

What Are the Published CEC Specifications for Heliene 60P220?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 60P220. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Heliene 60P220.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 220.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 194.8 W (88.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.9 V / 7.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.316 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.23% (1.663 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Heliene 60P220 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 60P220 (220.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.16 kW 501 sq ft $1,542 $2,607
8 kW Class 37 8.14 kW 662 sq ft $2,037 $3,445
10 kW Class 46 10.12 kW 823 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 60P220 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Heliene 60P220 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 60P215 215.0 W 190.2 W 36.5 V 28.6 V 12.93%
Heliene 60P220 220.0 W 194.8 W 36.6 V 28.9 V 13.23%

How Many Heliene 60P220 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 60P220 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.6V and beta_Voc=-0.316%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.8 V 14 panels 585.2 V 23 panels
-10 C (14 F) 40.65 V 14 panels 569.1 V 24 panels
0 C (32 F) 39.49 V 15 panels 592.4 V 25 panels
25 C (77 F STC) 36.6 V 16 panels 585.6 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 60P220?

Alternative CEC solar modules from competing brands near Heliene 60P220 (220.0 W), including Grape Solar GS-P-220-CS. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Grape Solar GS-P-220-CS
Grape Solar
220.0 W Tie (0 W) 36.6 V 13.68% 91.6%
Guangdong Golden Glass Technologies GG220M2-30/1640x992
Guangdong Golden Glass Technologies
220.0 W Tie (0 W) 36.6 V 13.52% 90.2%
APOS Energy AS220
APOS Energy
220.0 W Tie (0 W) 36.63 V 13.26% 89.5%
Gintung Energy ASEC-220G6M
Gintung Energy
220.0 W Tie (0 W) 36.57 V 13.66% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 60P220?

Evaluate Heliene 60P220 (220.0 W STC, 36.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 60P220 reaches 41.8 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 37 panels for an 8 kW build require 662 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (662 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 60P220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 60P220 8 kW Residential Fit

Needs 37 modules (662 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Grape Solar GS-P-220-CS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 194.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 60P220 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

What fuse or breaker size does NEC 690.8 require for Heliene 60P220?

Multiplying Heliene 60P220's 8.18 A short-circuit current by 1.56 equals 12.76 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 60P220 before finalizing component orders.

Can Heliene 60P220 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.65 V cold Voc at 14 F and handles 8.18 A Isc; string inverters cap Heliene 60P220 at 14 panels on 600 V.

Is Heliene 60P220 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 60P220 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.