Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72M-385 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M-385 is a 385.0 W STC (355.6 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.54% efficiency, 48.62 V Voc at 25 C, and 53.15 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
355.6 W
Voc @ 25C
48.62 V
Efficiency
19.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M-385 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 72M-385 (Mono-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Homeowners evaluating Heliene 72M-385 need 16 panels for 6 kW or 21 panels (445 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (445 sq ft). Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 53.15 V at 14 F and 54.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Heliene 72M-385 Fall Across Listed CEC Models?

Comparison of Heliene 72M-385 (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M-385 (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M-385: 385.0 W

What Dataset Percentiles Define Heliene 72M-385?

Relative ranking of Heliene 72M-385 across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Heliene 72M-385 Engineering BenchmarksPercentile comparison of Heliene 72M-385 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.4%Module Efficiency19.54%

What Do the Dataset Ranks Show for Heliene 72M-385?

Summary of Heliene 72M-385 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,046

19.54% Aperture Efficiency

Power density 195.4 W/m2 (0.37 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.15 V at -10 C (584.6 V string) and 54.44 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 41.4 m2 (445 sq ft) producing 7,468 W PTC; NEC 690.8 OCPD floor is 15.88 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.62 * (1 + (-0.266/100) * (-10 - 25)) = 53.15 V | OCPD = 1.56 * 10.18 = 15.88 A

Inputs from CEC Modules.csv for Heliene 72M-385: Voc=48.62 V, beta_Voc=-0.266%/C, Isc=10.18 A, STC=385.0 W, Area=1.97 m2.

Result: 11 panels max on 600 V (584.6 V); 21 panels for 8 kW (445 sq ft).

What Are the Published CEC Specifications for Heliene 72M-385?

Complete CEC test sheet for Heliene 72M-385 including Isc (10.18 A), Voc (48.62 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-385.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 355.6 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.62 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.81 V / 9.67 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.54% (1.97 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 72M-385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 72M-385.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 339 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 445 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 551 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 72M-385 series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 72M-385 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72M-375 375.0 W 347.8 W 48.96 V 40.67 V 19.53%
Heliene 72M-380 380.0 W 352.6 W 49.55 V 41.2 V 19.79%
Heliene 72M-385 385.0 W 355.6 W 48.62 V 39.81 V 19.54%
Heliene 72M-390 390.0 W 360.4 W 48.94 V 40.11 V 19.8%

How Many Heliene 72M-385 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 72M-385 (48.62 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.62V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.44 V 11 panels 598.8 V 18 panels
-10 C (14 F) 53.15 V 11 panels 584.6 V 18 panels
0 C (32 F) 51.85 V 11 panels 570.4 V 19 panels
25 C (77 F STC) 48.62 V 12 panels 583.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-385?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612M-385-H (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 18.97% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M-385?

Evaluate Heliene 72M-385 (385.0 W STC, 48.62 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-385 reaches 54.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (445 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72M-385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M-385 8 kW Residential Fit

Needs 21 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-385-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 355.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-385 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Why is Heliene 72M-385 PTC wattage (355.6 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 355.6 W PTC (92.4% retention) across Heliene 72M-385's 1.97 m2 aperture.

Who should skip Heliene 72M-385 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Heliene 72M-385 panels (445 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612M-385-H.

What is the 1,000 V commercial string limit for Heliene 72M-385?

On 1,000 V commercial inverters at -10 C (53.15 V cold Voc), Heliene 72M-385 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 72M-385.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.