Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 60P255 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 60P255 is a 255.0 W STC (227.9 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.54% efficiency, 39.9 V Voc at 25 C, and 44.1 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
227.9 W
Voc @ 25C
39.9 V
Efficiency
15.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 60P255 Compare Against Peer CEC Listings?

How Heliene Heliene 60P255 handles rooftop heat (227.9 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 60P255 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 155.4 W/m2 (4.37 percentage points below 19.91% CEC median). Compared against Changzhou Nesl Solartech DJ-255D/C-ST15 (255.0 W), this model holds typical 89.4% PTC-to-STC thermal output (227.9 W real-world rating). Lower 39.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.59 A overcurrent floor served by a 15 A breaker.

Where Does Heliene 60P255 Fall Across Listed CEC Models?

Where Heliene 60P255 (255.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 60P255 (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 60P255: 255.0 W

What Dataset Percentiles Define Heliene 60P255?

Percentile placement of Heliene 60P255 across power density (155.4 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Heliene 60P255 Engineering BenchmarksPercentile comparison of Heliene 60P255 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention89.4%Module Efficiency15.54%

What Do the Dataset Ranks Show for Heliene 60P255?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 60P255 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,868

15.54% Aperture Efficiency

Power density 155.4 W/m2 (4.37 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.1 V at -10 C (573.3 V string) and 45.3 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.5 m2 (565 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 13.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.9 * (1 + (-0.301/100) * (-10 - 25)) = 44.1 V | OCPD = 1.56 * 8.71 = 13.59 A

Inputs from CEC Modules.csv for Heliene 60P255: Voc=39.9 V, beta_Voc=-0.301%/C, Isc=8.71 A, STC=255.0 W, Area=1.641 m2.

Result: 13 panels max on 600 V (573.3 V); 32 panels for 8 kW (565 sq ft).

What Are the Published CEC Specifications for Heliene 60P255?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 60P255. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Heliene 60P255.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 227.9 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.95 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.54% (1.641 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Heliene 60P255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 60P255 (255.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 424 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 565 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 707 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 60P255 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Heliene 60P255 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 60P250 250.0 W 223.3 W 37.8 V 30.7 V 15.23%
Heliene 60P255 255.0 W 227.9 W 39.9 V 30.95 V 15.54%
Heliene 60P260 260.0 W 232.6 W 38.0 V 30.71 V 16.1%

How Many Heliene 60P255 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 60P255 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.9V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.3 V 13 panels 588.9 V 22 panels
-10 C (14 F) 44.1 V 13 panels 573.3 V 22 panels
0 C (32 F) 42.9 V 13 panels 557.7 V 23 panels
25 C (77 F STC) 39.9 V 15 panels 598.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 60P255?

Alternative CEC solar modules from competing brands near Heliene 60P255 (255.0 W), including Changzhou Nesl Solartech DJ-255D/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Changzhou Nesl Solartech DJ-255D/C-ST15
Changzhou Nesl Solartech
255.0 W Tie (0 W) 38.19 V 15.61% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 60P255?

Evaluate Heliene 60P255 (255.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 60P255 reaches 45.3 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 565 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (565 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 60P255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 60P255 8 kW Residential Fit

Needs 32 modules (565 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-255D/C-ST15.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 227.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 60P255 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

What fuse or breaker size does NEC 690.8 require for Heliene 60P255?

Multiplying Heliene 60P255's 8.71 A short-circuit current by 1.56 equals 13.59 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 60P255 before finalizing component orders.

Can Heliene 60P255 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.1 V cold Voc at 14 F and handles 8.71 A Isc; string inverters cap Heliene 60P255 at 13 panels on 600 V.

Is Heliene 60P255 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 60P255 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.