Heliene 96M445 is a 445.0 W STC (401.8 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 17.66% efficiency, 61.19 V Voc at 25 C, and 67.83 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 401.8 W
- Voc @ 25C
- 61.19 V
- Efficiency
- 17.66%
How Does Heliene 96M445 Compare Against Peer CEC Listings?
Engineering position of Heliene 96M445 (445.0 W STC) vs. CSI Solar Co Ltd CS3Y-445P across 5,889 CEC Mono-c-Si solar modules.
Ranking #6,028 across 21,677 CEC solar panels (top 29.6%; higher than 70.4% of peers), Heliene 96M445 operates as a modern high-density residential and light-commercial module sitting 35.0 W above the 410.0 W Mono-c-Si median. Higher 61.19 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C). With typical 90.3% PTC-to-STC thermal output (401.8 W real-world rating), 18 panels occupy 488 sq ft and offset roughly $2,005/yr at average US rates (or $3,390/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Heliene 96M445 Fall Across Listed CEC Models?
Plots Heliene 96M445 at 445.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 96M445?
Benchmarks Heliene 96M445 on STC wattage, thermal PTC/STC retention, and 17.66 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Heliene 96M445?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 96M445 by Heliene.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.66% Aperture Efficiency
Power density 176.6 W/m2 (2.25 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 67.83 V at -10 C (542.6 V string) and 69.73 V at -20 C (8 max).
18 Panels = 8,010 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,232 W PTC; NEC 690.8 OCPD floor is 14.66 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 61.19 * (1 + (-0.31/100) * (-10 - 25)) = 67.83 V | OCPD = 1.56 * 9.4 = 14.66 A
Inputs from CEC Modules.csv for Heliene 96M445: Voc=61.19 V, beta_Voc=-0.31%/C, Isc=9.4 A, STC=445.0 W, Area=2.52 m2.
Result: 8 panels max on 600 V (542.6 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for Heliene 96M445?
Laboratory test ratings recorded for Heliene 96M445 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 401.8 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 61.19 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 50.86 V / 8.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.66% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 96 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 96M445 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (488 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 96M445.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 380 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 488 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 624 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Sibling wattage bins and frame colors grouped with Heliene 96M445 under Heliene to prevent duplicate spec pages. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 96M440 | 440.0 W | 397.1 W | 60.99 V | 50.66 V | 17.46% |
| Heliene 96M445 | 445.0 W | 401.8 W | 61.19 V | 50.86 V | 17.66% |
How Many Heliene 96M445 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Heliene 96M445 (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 69.73 V | 8 panels | 557.8 V | 14 panels |
| -10 C (14 F) | 67.83 V | 8 panels | 542.6 V | 14 panels |
| 0 C (32 F) | 65.93 V | 9 panels | 593.4 V | 15 panels |
| 25 C (77 F STC) | 61.19 V | 9 panels | 550.7 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 96M445?
Closest cross-brand CEC competitors to Heliene 96M445 matched near 445.0 W STC and 61.19 V Voc, led by CSI Solar Co Ltd CS3Y-445P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | Tie (0 W) | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.3 V | 20.56% | 92.6% |
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | -5.0 W | 49.2 V | 20.47% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Heliene 96M445?
Evaluate Heliene 96M445 (445.0 W STC, 61.19 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 96M445 reaches 69.73 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 96M445 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 96M445 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 401.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 96M445 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
How many Heliene 96M445 panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 96M445 cold Voc rises from 61.19 V to 67.83 V (beta_Voc -0.31%/C), capping a 600 V string at 8 panels (542.6 V).
How much roof area does an 8 kW array of Heliene 96M445 need?
An 8 kW DC system uses 18 Heliene 96M445 modules (8,010 W STC / 7,232 W PTC), covering roughly 488 sq ft and saving ~$2,005/yr at 18.54 c/kWh.
How does Heliene 96M445 compare against CSI Solar Co Ltd CS3Y-445P?
Heliene 96M445 outputs 445.0 W STC (61.19 V Voc, rank #6,028 of 21,677), while CSI Solar Co Ltd CS3Y-445P delivers 445.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)