Skip to main content
WireAndSun
Calculators
CEC PV Module

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W — CEC Solar Module Specifications

Manufacturer: Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Registry: CEC Verified Engineering Specification

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W is a 440.0 W STC (406.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.75% efficiency, 49.6 V Voc at 25 C, and 54.44 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
406.6 W
Voc @ 25C
49.6 V
Efficiency
20.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Compare Against Peer CEC Listings?

How Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W handles rooftop heat (406.6 W PTC), 8 kW sizing, and cold winter string voltage.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd builds the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 207.5 W/m2 (0.84 percentage points above 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M672BH-440TW (440.0 W), this model holds strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 17.67 A overcurrent floor served by a 20 A breaker.

Where Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Fall Across Listed CEC Models?

Where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAmerisolar-Worldwi: 440.0 W

What Dataset Percentiles Define Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Percentile placement of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W across power density (207.5 W/m2), thermal retention, and nameplate STC wattage.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Engineering BenchmarksPercentile comparison of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention92.4%Module Efficiency20.75%

What Do the Dataset Ranks Show for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W specifications.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,496

20.75% Aperture Efficiency

Power density 207.5 W/m2 (0.84 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.44 V at -10 C (598.8 V string) and 55.83 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,725 W PTC; NEC 690.8 OCPD floor is 17.67 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.279/100) * (-10 - 25)) = 54.44 V | OCPD = 1.56 * 11.33 = 17.67 A

Inputs from CEC Modules.csv for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W: Voc=49.6 V, beta_Voc=-0.279%/C, Isc=11.33 A, STC=440.0 W, Area=2.12 m2.

Result: 11 panels max on 600 V (598.8 V); 19 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Official California Energy Commission (NREL SAM) test parameters for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 406.6 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.0 V / 10.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.75% (2.12 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (440.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 319 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 434 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 525 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Series?

All closely matched Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd wattages and cosmetic trims sharing the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W architecture.

Sibling CEC listings grouped into the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-430W 430.0 W 397.0 W 49.2 V 40.6 V 20.28%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-435W 435.0 W 401.8 W 49.4 V 40.8 V 20.52%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W 440.0 W 406.6 W 49.6 V 41.0 V 20.75%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-445W 445.0 W 411.3 W 49.8 V 41.2 V 20.99%

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Modules Fit in a Cold-Weather String?

Maximum series module counts for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.6V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.83 V 10 panels 558.3 V 17 panels
-10 C (14 F) 54.44 V 11 panels 598.8 V 18 panels
0 C (32 F) 53.06 V 11 panels 583.7 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Alternative CEC solar modules from competing brands near Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (440.0 W), including Apollo Renewables Inc Apollo-M672BH-440TW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
Bluesun Solar CoLtd BSM440M-72HPH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 49.2 V 20.28% 92.7%
ELITE Solar ET-M672BH440TW
ELITE Solar
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
ELITE Solar ET-M672BH440WW
ELITE Solar
440.0 W Tie (0 W) 48.9 V 20.47% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Evaluate Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W (440.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W reaches 55.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (434 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W 8 kW Residential Fit

Needs 19 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M672BH-440TW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 406.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W?

Multiplying Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W's 11.33 A short-circuit current by 1.56 equals 17.67 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.44 V cold Voc at 14 F and handles 11.33 A Isc; string inverters cap Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W at 11 panels on 600 V.

Is Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.