Skip to main content
WireAndSun
Calculators
CEC PV Module

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W — CEC Solar Module Specifications

Manufacturer: Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Registry: CEC Verified Engineering Specification

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W is a 405.0 W STC (375.0 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.2% efficiency, 49.2 V Voc at 25 C, and 53.73 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
375.0 W
Voc @ 25C
49.2 V
Efficiency
21.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Compare Against Peer CEC Listings?

How Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W handles rooftop heat (375.0 W PTC), 8 kW sizing, and cold winter string voltage.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd builds the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3U-405MS (405.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.41 A overcurrent floor served by a 20 A breaker.

Where Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Fall Across Listed CEC Models?

Where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAmerisolar-Worldwi: 405.0 W

What Dataset Percentiles Define Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Percentile placement of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W across power density (212.0 W/m2), thermal retention, and nameplate STC wattage.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Engineering BenchmarksPercentile comparison of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.6%Module Efficiency21.2%

What Do the Dataset Ranks Show for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W specifications.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,580

21.2% Aperture Efficiency

Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.73 V at -10 C (591.0 V string) and 55.02 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.2 m2 (411 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 16.41 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.2 * (1 + (-0.263/100) * (-10 - 25)) = 53.73 V | OCPD = 1.56 * 10.52 = 16.41 A

Inputs from CEC Modules.csv for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W: Voc=49.2 V, beta_Voc=-0.263%/C, Isc=10.52 A, STC=405.0 W, Area=1.91 m2.

Result: 11 panels max on 600 V (591.0 V); 20 panels for 8 kW (411 sq ft).

What Are the Published CEC Specifications for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W.

Official California Energy Commission (NREL SAM) test parameters for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 375.0 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.5 V / 10.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.2% (1.91 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 308 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 411 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 514 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Series?

All closely matched Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd wattages and cosmetic trims sharing the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W architecture.

Sibling CEC listings grouped into the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-400W 400.0 W 370.2 W 49.0 V 40.3 V 20.94%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W 405.0 W 375.0 W 49.2 V 40.5 V 21.2%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-410W 410.0 W 379.7 W 49.4 V 40.7 V 21.47%

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Modules Fit in a Cold-Weather String?

Maximum series module counts for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.2V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.02 V 10 panels 550.2 V 18 panels
-10 C (14 F) 53.73 V 11 panels 591.0 V 18 panels
0 C (32 F) 52.43 V 11 panels 576.7 V 19 panels
25 C (77 F STC) 49.2 V 12 panels 590.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Alternative CEC solar modules from competing brands near Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (405.0 W), including CSI Solar Co Ltd CS3U-405MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-405MS
CSI Solar Co Ltd
405.0 W Tie (0 W) 49.3 V 21.09% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W
Dehui Solar Power (Vietnam) CoLtd
405.0 W Tie (0 W) 49.1 V 20.77% 93.0%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Evaluate Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W (405.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W reaches 55.02 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W 8 kW Residential Fit

Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3U-405MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W?

Multiplying Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W's 10.52 A short-circuit current by 1.56 equals 16.41 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.73 V cold Voc at 14 F and handles 10.52 A Isc; string inverters cap Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W at 11 panels on 600 V.

Is Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.