Heliene 96M410 is a 410.0 W STC (366.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 15.93% efficiency, 60.25 V Voc at 25 C, and 67.93 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 366.3 W
- Voc @ 25C
- 60.25 V
- Efficiency
- 15.93%
How Does Heliene 96M410 Compare Against Peer CEC Listings?
Engineering position of Heliene 96M410 (410.0 W STC) vs. CSI Solar Co Ltd CS1Y-410MS across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,539 across 21,677 CEC solar panels (top 41.3%; higher than 58.7% of peers), Heliene 96M410 operates as a modern high-density residential and light-commercial module sitting equal to the 410.0 W Mono-c-Si median. Higher 60.25 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C). With typical 89.3% PTC-to-STC thermal output (366.3 W real-world rating), 20 panels occupy 554 sq ft and offset roughly $2,052/yr at average US rates (or $3,470/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Heliene 96M410 Fall Across Listed CEC Models?
Plots Heliene 96M410 at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 96M410?
Benchmarks Heliene 96M410 on STC wattage, thermal PTC/STC retention, and 15.93 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Heliene 96M410?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 96M410 by Heliene.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.93% Aperture Efficiency
Power density 159.3 W/m2 (3.98 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 67.93 V at -10 C (543.4 V string) and 70.12 V at -20 C (8 max).
20 Panels = 8,200 W STC
Occupies 51.5 m2 (554 sq ft) producing 7,326 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 60.25 * (1 + (-0.364/100) * (-10 - 25)) = 67.93 V | OCPD = 1.56 * 8.9 = 13.88 A
Inputs from CEC Modules.csv for Heliene 96M410: Voc=60.25 V, beta_Voc=-0.364%/C, Isc=8.9 A, STC=410.0 W, Area=2.574 m2.
Result: 8 panels max on 600 V (543.4 V); 20 panels for 8 kW (554 sq ft).
What Are the Published CEC Specifications for Heliene 96M410?
Laboratory test ratings recorded for Heliene 96M410 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 366.3 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 60.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 48.98 V / 8.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.364 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.93% (2.574 m2) | Array roof footprint density |
| Cell Count & Technology | 96 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 96M410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (554 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 96M410.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 416 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 554 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 693 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Sibling wattage bins and frame colors grouped with Heliene 96M410 under Heliene to prevent duplicate spec pages. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 96M400 | 400.0 W | 357.1 W | 59.8 V | 48.43 V | 15.54% |
| Heliene 96M405 | 405.0 W | 361.7 W | 60.0 V | 48.68 V | 15.73% |
| Heliene 96M410 | 410.0 W | 366.3 W | 60.25 V | 48.98 V | 15.93% |
| Heliene 96M415 | 415.0 W | 370.9 W | 60.4 V | 49.23 V | 16.12% |
| Heliene 96M420 | 420.0 W | 375.5 W | 60.55 V | 49.53 V | 16.32% |
How Many Heliene 96M410 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Heliene 96M410 (beta_Voc -0.364%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 70.12 V | 8 panels | 561.0 V | 14 panels |
| -10 C (14 F) | 67.93 V | 8 panels | 543.4 V | 14 panels |
| 0 C (32 F) | 65.73 V | 9 panels | 591.6 V | 15 panels |
| 25 C (77 F STC) | 60.25 V | 9 panels | 542.2 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 96M410?
Closest cross-brand CEC competitors to Heliene 96M410 matched near 410.0 W STC and 60.25 V Voc, led by CSI Solar Co Ltd CS1Y-410MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Heliene 96M410?
Evaluate Heliene 96M410 (410.0 W STC, 60.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 96M410 reaches 70.12 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 554 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (554 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 96M410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 96M410 8 kW Residential Fit
Needs 20 modules (554 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 96M410 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
How many Heliene 96M410 panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 96M410 cold Voc rises from 60.25 V to 67.93 V (beta_Voc -0.364%/C), capping a 600 V string at 8 panels (543.4 V).
How much roof area does an 8 kW array of Heliene 96M410 need?
An 8 kW DC system uses 20 Heliene 96M410 modules (8,200 W STC / 7,326 W PTC), covering roughly 554 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does Heliene 96M410 compare against CSI Solar Co Ltd CS1Y-410MS?
Heliene 96M410 outputs 410.0 W STC (60.25 V Voc, rank #8,539 of 21,677), while CSI Solar Co Ltd CS1Y-410MS delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)