Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72M360 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M360 is a 360.0 W STC (326.5 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.93% efficiency, 48.1 V Voc at 25 C, and 53.3 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
326.5 W
Voc @ 25C
48.1 V
Efficiency
18.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M360 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 72M360 (Mono-c-Si) residential solar systems. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Heliene 72M360 delivers 189.3 W/m2 (0.98 percentage points below 19.91% CEC median) and typical 90.7% PTC-to-STC thermal output (326.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (471 sq ft). At -4 F (-20 C), string voltage climbs to 54.79 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Advance Power API-M360 (360.0 W).

Where Does Heliene 72M360 Fall Across Listed CEC Models?

Comparison of Heliene 72M360 (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M360 (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M360: 360.0 W

What Dataset Percentiles Define Heliene 72M360?

Relative ranking of Heliene 72M360 across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Heliene 72M360 Engineering BenchmarksPercentile comparison of Heliene 72M360 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention90.7%Module Efficiency18.93%

What Do the Dataset Ranks Show for Heliene 72M360?

Summary of Heliene 72M360 output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,602

18.93% Aperture Efficiency

Power density 189.3 W/m2 (0.98 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.3 V at -10 C (586.3 V string) and 54.79 V at -20 C (10 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 43.7 m2 (471 sq ft) producing 7,510 W PTC; NEC 690.8 OCPD floor is 15.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.1 * (1 + (-0.309/100) * (-10 - 25)) = 53.3 V | OCPD = 1.56 * 9.71 = 15.15 A

Inputs from CEC Modules.csv for Heliene 72M360: Voc=48.1 V, beta_Voc=-0.309%/C, Isc=9.71 A, STC=360.0 W, Area=1.902 m2.

Result: 11 panels max on 600 V (586.3 V); 23 panels for 8 kW (471 sq ft).

What Are the Published CEC Specifications for Heliene 72M360?

Complete CEC test sheet for Heliene 72M360 including Isc (9.71 A), Voc (48.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M360.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 326.5 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.71 V / 9.13 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.309 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.93% (1.902 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 72M360 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 72M360.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 348 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 471 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 573 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 72M360 series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Heliene 72M360 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72M350 350.0 W 317.1 W 47.54 V 39.13 V 18.4%
Heliene 72M355 355.0 W 321.8 W 47.82 V 39.42 V 18.66%
Heliene 72M360 360.0 W 326.5 W 48.1 V 39.71 V 18.93%
Heliene 72M365 365.0 W 331.2 W 48.38 V 39.95 V 19.19%
Heliene 72M370 370.0 W 335.9 W 48.66 V 40.15 V 19.45%

How Many Heliene 72M360 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 72M360 (48.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.1V and beta_Voc=-0.309%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.79 V 10 panels 547.9 V 18 panels
-10 C (14 F) 53.3 V 11 panels 586.3 V 18 panels
0 C (32 F) 51.82 V 11 panels 570.0 V 19 panels
25 C (77 F STC) 48.1 V 12 panels 577.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M360?

Four comparable CEC modules such as Advance Power API-M360 (360.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M360
Advance Power
360.0 W Tie (0 W) 47.56 V 18.56% 91.7%
Auxin Solar AXN6M612T360
Auxin Solar
360.0 W Tie (0 W) 47.56 V 18.55% 91.7%
Boviet Solar Technology Co Ltd BVM6612M-360
Boviet Solar Technology Co Ltd
360.0 W Tie (0 W) 47.5 V 18.56% 92.3%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
360.0 W Tie (0 W) 47.46 V 18.55% 91.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M360?

Evaluate Heliene 72M360 (360.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M360 reaches 54.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (471 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72M360 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M360 8 kW Residential Fit

Needs 23 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Advance Power API-M360.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 326.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M360 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many Heliene 72M360 panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 72M360 cold Voc rises from 48.1 V to 53.3 V (beta_Voc -0.309%/C), capping a 600 V string at 11 panels (586.3 V).

How much roof area does an 8 kW array of Heliene 72M360 need?

An 8 kW DC system uses 23 Heliene 72M360 modules (8,280 W STC / 7,510 W PTC), covering roughly 471 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does Heliene 72M360 compare against Advance Power API-M360?

Heliene 72M360 outputs 360.0 W STC (48.1 V Voc, rank #12,385 of 21,677), while Advance Power API-M360 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.