Heliene 120HC-370 is a 370.0 W STC (347.1 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 20.22% efficiency, 41.22 V Voc at 25 C, and 45.13 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 347.1 W
- Voc @ 25C
- 41.22 V
- Efficiency
- 20.22%
How Does Heliene 120HC-370 Compare Against Peer CEC Listings?
Engineering position of Heliene 120HC-370 (370.0 W STC) vs. CSI Solar Co Ltd CS3L-375P across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Heliene 120HC-370 pairs strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677) with 41.22 V nominal Voc. An 8 kW residential build (8,140 W DC, 7,636 W PTC) saves ~$2,037/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3L-375P offers a 375.0 W alternative.
Where Does Heliene 120HC-370 Fall Across Listed CEC Models?
Plots Heliene 120HC-370 at 370.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 120HC-370?
Benchmarks Heliene 120HC-370 on STC wattage, thermal PTC/STC retention, and 20.22 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Heliene 120HC-370?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 120HC-370 by Heliene.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.22% Aperture Efficiency
Power density 202.2 W/m2 (0.31 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.13 V at -10 C (586.7 V string) and 46.25 V at -20 C (12 max).
22 Panels = 8,140 W STC
Occupies 40.3 m2 (433 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 18.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.22 * (1 + (-0.271/100) * (-10 - 25)) = 45.13 V | OCPD = 1.56 * 11.75 = 18.33 A
Inputs from CEC Modules.csv for Heliene 120HC-370: Voc=41.22 V, beta_Voc=-0.271%/C, Isc=11.75 A, STC=370.0 W, Area=1.83 m2.
Result: 13 panels max on 600 V (586.7 V); 22 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for Heliene 120HC-370?
Laboratory test ratings recorded for Heliene 120HC-370 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 347.1 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.22 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.12 V / 10.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.22% (1.83 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 120HC-370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (433 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 120HC-370.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 335 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 433 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 552 sq ft | $2,593 | $4,385 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Sibling wattage bins and frame colors grouped with Heliene 120HC-370 under Heliene to prevent duplicate spec pages. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 120HC-365 | 365.0 W | 342.3 W | 41.04 V | 34.99 V | 19.95% |
| Heliene 120HC-370 | 370.0 W | 347.1 W | 41.22 V | 35.12 V | 20.22% |
How Many Heliene 120HC-370 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Heliene 120HC-370 (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.25 V | 12 panels | 555.0 V | 21 panels |
| -10 C (14 F) | 45.13 V | 13 panels | 586.7 V | 22 panels |
| 0 C (32 F) | 44.01 V | 13 panels | 572.1 V | 22 panels |
| 25 C (77 F STC) | 41.22 V | 14 panels | 577.1 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 120HC-370?
Closest cross-brand CEC competitors to Heliene 120HC-370 matched near 370.0 W STC and 41.22 V Voc, led by CSI Solar Co Ltd CS3L-375P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | +5.0 W | 41.2 V | 20.95% | 92.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | +5.0 W | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | +5.0 W | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | +5.0 W | 41.1 V | 20.49% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Heliene 120HC-370?
Evaluate Heliene 120HC-370 (370.0 W STC, 41.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 120HC-370 reaches 46.25 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 120HC-370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 120HC-370 8 kW Residential Fit
Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 347.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 120HC-370 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What fuse or breaker size does NEC 690.8 require for Heliene 120HC-370?
Multiplying Heliene 120HC-370's 11.75 A short-circuit current by 1.56 equals 18.33 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 120HC-370 before finalizing component orders.
Can Heliene 120HC-370 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.13 V cold Voc at 14 F and handles 11.75 A Isc; string inverters cap Heliene 120HC-370 at 13 panels on 600 V.
Is Heliene 120HC-370 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 120HC-370 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)